Model Predictive Control for Dynamic Hydraulic Balancing in Building Radiator Heating Systems: Modeling, Design, and Experimental Validation

Erfan Shakhesi, Maurice Heemels, Paula Chanfreut

eess.SY math.OC ·submitted 2026-09-08 13:06 UTC · v1

Abstract

Hydronic radiator systems are among the most widely used heating systems in buildings. In the literature, radiator heat outputs are often assumed to be independent of one another and arbitrarily adjustable in time when designing controllers. However, in practice, radiators are supplied by one or multiple common heat sources and are hydraulically coupled through the water circulation system. Maintaining occupant comfort in multi-zone buildings therefore requires not only an appropriate supply temperature but also proper hydraulic balancing to distribute the available water flow according to the heating demand of each zone. To this end, we develop a grey-box thermal model that captures the hydraulic interactions among radiators and the effects of radiator valves, circulation pumps, and heat sources. In a real building, we show that accounting for hydraulic interactions reduces the root mean square error (RMSE) between the measured and modeled zone temperatures by approximately 11% compared with a model that neglects these interactions. Additionally, we integrate the developed model into a model predictive control (MPC) framework for dynamic hydraulic balancing that jointly optimizes valve openings and the supply temperature to maintain thermal comfort in each zone while reducing energy consumption. Through both real-world experiments and numerical case studies, we demonstrate that, compared with existing MPC formulations that neglect hydraulic interactions or do not control radiator valves, the proposed MPC reduces comfort-range violations by at least 27% while requiring a similar or even lower cumulative supply temperature.

Closest papers

Nearest neighbours by meaning across the whole index.

Model Predictive Control of Heating Systems via Koopman-Operator Bilinearization

eess.SY ·2026-11-02 ·Paula Chanfreut, Erfan Shakhesi, Mircea Lazar, Maurice Heemels
similarity 0.66
Abstract

Hydronic heat emitters are widely used in buildings, but their control is challenging due to nonlinear dynamics, arising from both the heat transfer in each emitter and the hydraulic coupling among those that share a circulating pump. These nonlinearities are often simplified or neglected in the literature. In this paper, we use Koopman theory to make the resulting model more tractable for control. In particular, we propose an input reparameterization and construct an infinite-dimensional set of observables that yields an exact bilinear representation of the system in the chosen lifted space. We then show that truncating the infinite-dimensional representation leads to bounded approximation errors that decrease as the truncation order increases, as well as bounded trajectory deviations over a finite horizon. The resulting bilinear model is incorporated into a model predictive control (MPC) framework to provide thermal comfort in multi-zone buildings while reducing energy use. Using a numerical case study of a five-story building with 20 zones, we show that the proposed Koopman-based MPC achieves a realized performance cost close to that of nonlinear MPC with faster solve times, and outperforms MPC formulations based on time-invariant and time-varying linearizations.

0.27

User-specified Kelvin-hour budgets within model predictive control for energy-efficient buildings: Simulation and field demonstration

eess.SY ·2026-09-06 ·Jicheng Shi, Colin N. Jones
similarity 0.62
Abstract

For energy-efficient building control, model predictive control (MPC) has been widely proposed to reduce energy use while maintaining prescribed indoor temperature bounds. In practice, MPC implementations may still produce temperature-bound violations because of model mismatch, weather-forecast errors, and softened constraints introduced to preserve feasibility. Existing soft- constrained MPC usually handles this trade-off through slack-weight tuning, so users cannot prescribe a violation-severity budget before operation. This paper develops a Kelvin-hour (Kh)-budget MPC that allows users to specify a running-average budget for temperature-bound violation severity. During operation, the controller uses the realized Kh budget surplus or overspend to update the temperature bounds, providing step-by-step budget feedback. We evaluate the method in two high-fidelity BOPTEST simulation cases and in an occupied residential deployment. In the first one-zone case, prescribed budgets produce clear running-average Kh violation responses across predictors and disturbance settings. At a prescribed budget of 0.005 Kh/step, the controller reduces energy use by 31.9% and Kh violation by 36.2% relative to the built-in default controller. In the second coupled two-zone case, separate zone budgets produce zone-level responses, with 18.9%-20.5% energy reduction and 9.4%-64.3% zone-level Kh violation reduction. In the occupied residential deployment, the running-average Kh violations remain close to or below their prescribed budgets under real sensing, actuation, weather, and occupancy conditions.

0.27

Model-Free Control for Residential Heating: Deployment and Simulation of Nonlinear Data-Enabled Predictive Control

eess.SY math.OC ·2026-09-18 ·Sebastian Zieglmeier, Chris Verhoek, Jaap Eising, Mathias Hudoba de Badyn
similarity 0.61
Abstract · 19 pages, 8 figures, 7 tables

Residential heating accounts for a large share of building energy use, and predictive control strategies can reduce it by anticipating rather than reacting to the room temperature alone. The usual manner of implementing predictive control, model predictive control (MPC), requires an accurate model of each individual residential unit for heating control. Obtaining this model is time-consuming to obtain manually or even impossible, and such models do not transfer across a heterogeneous building stock. Data-enabled predictive control (DeePC) removes this modeling step by designing the controller directly using measured trajectories of the system. The foundations of DeePC, however, are built on the class of deterministic linear time-invariant systems, which is an unrealistic assumption for residential heating. This work applies three recently proposed nonlinear extensions of DeePC, collectively referred to as data-driven predictive control (DPC): Select-DPC, gain-scheduling DPC, and linear parameter-varying DPC. These are compared against standard DeePC and the hysteresis controller, the industry standard in residential heating. The comparison runs over a full heating season on a calibrated digital twin of an occupied research unit, the NEST research building in Switzerland, assessed by heating energy and comfort-band violation. Moreover, gain-scheduling DPC was deployed on the real residential apartment and validated the conclusions from the simulations. Each of the DPC controllers consumes significantly less energy than the hysteresis controller, amounting to roughly $11\%$ over the season, validating the use of DPC. The nonlinear methods further outperform linear DeePC in all assessed scenarios, and we analyze the relative costs and benefits of each nonlinear method.

0.41

Physics-informed neural control of heat flow rate in a counter-flow heat exchanger: modeling, identification and experimental validation

eess.SY ·2026-10-04 ·Konstantinos Skantzikas, Emmanuel Witrant, Bojan Mavkov
similarity 0.61
Abstract

The advanced operation of heat exchangers plays a critical role in the development of efficient and sustainable multivector energy systems. This paper proposes a hybrid physics-informed and data-driven framework for the analysis, identification, and regulation of transient heat transfer in counter-flow heat exchangers. A parameterized physical model combines classical heat-transfer relations with transport equations to capture convective propagation, transport-induced delays, and nonlinear effects associated with flow-rate variations. The heat-transfer coefficient is identified from experimental data, enabling the characterization of flow-dependent heat-transfer dynamics over a broad operating range. The identified model is then used to develop a hierarchical real-time control strategy. An inner loop regulates the volumetric flow rate using a high-order data-driven linear model, while an outer loop regulates the exchanged heat power using a machine-learning controller initially trained on the physical model and subsequently refined with experimental data. Experimental results demonstrate accurate reproduction of transient heat-transfer dynamics and effective heat-flow-rate regulation under varying thermal boundary conditions (identification fit above 94\% in normalized root-mean-square error and total variation of the flow rate reduced by half compared to a proportional-integral controller). The proposed framework combines physical interpretability with data-driven adaptation for the analysis and real-time operation of dynamic heat-transfer systems.

0.29

Online Optimization for Controlling HVAC Systems

eess.SY math.OC ·2026-11-05 ·Tong Wu, Dominik Baumann, Angela Fontan, Nicola Bastianello
similarity 0.59
Abstract

Heating, ventilation, and air-conditioning (HVAC) systems account for a significant portion of buildings' energy consumption, motivating the design of energy- and cost-efficient control strategies. However, conventional strategies employ simple, reactive control, without incorporating a model. Therefore, in this paper we adopt an economic model predictive control framework and focus on designing online algorithms to solve the control input design problems with a limited computational budget. In particular, we propose two tailored online algorithms based on projected gradient descent, with a custom projection routine, and the projected primal-dual method. We discuss the pros and cons of both algorithm designs, focusing in particular on computational efficiency. We further compare them through numerical experiments simulating the control of an HVAC system over the course of a day. The results show that computationally efficient online solvers for HVAC systems control are indeed possible. Moreover, the performance closely matches that of a baseline algorithm with unlimited computational budget, in terms of reference temperature tracking and comfort temperature range enforcement.

0.30

Adjacent Heat Transfer Effects Can Bias Savings Estimates When Controlling Only Part of a Multi-Zone Building

eess.SY ·2026-11-12 ·Arash J. Khabbazi, Kevin J. Kircher
publishedtheory similarity 0.58
Abstract · 10 pages. Accepted at the 2027 ASHRAE Winter Conference

Field demonstrations of advanced heating, ventilation, and air-conditioning control often operate a few thermal zones within a larger building and report savings for those zones alone. A recent theorem showed that this practice overestimates whole-building savings, because heat drawn from the neighboring zones is paid for by their equipment and is not counted. The error grows with the thermal conductance between the controlled and uncontrolled zones, with how much colder the controlled zones run over the test, and with the price of the heat their neighbors supply. For one controlled zone with one neighbor, a single thermal price, and slowly changing prices, the relative error reduces to the ratio of two conductances, a screening number that can be evaluated from the two conductances before a demonstration begins. This paper tests how far that reduction can be taken. A two-story house with one thermal zone per floor is simulated over a 90-day heating season in West Lafayette, Indiana, with receding-horizon model predictive control on the first floor and setpoint control on the second, under four combinations of electricity tariff (time-of-use or flat) and heating plant (heat pump or electric resistance). The exact correction from the theorem recovers the true savings in every case, and the full theorem, evaluated from the controlled zone's temperatures, the prices, and the building parameters, reproduces the measured relative error in every case. The conductance ratio bounds that error from above in all four cases, tightly under a flat tariff, within 3%, and loosely under a time-of-use tariff, where most of the controller's savings come from shifting load through the thermal mass rather than from lowering the temperature.

0.30

Deep Reinforcement Learning for Heat Pump and Underfloor Heating Control: An End-to-End Case Study

cs.AI eess.SY ·2026-11-17 ·Antonio Manjavacas, David Suárez-Caro, Alejandro Campoy-Nieves, Guillermo Rey, Gonzalo Satrústegui +1 more
similarity 0.56
Abstract · Preprint submited to journal

Efficient control of underfloor heating (UFH) systems coupled with heat pumps (HPs) is challenging due to the high thermal inertia of buildings and the slow dynamic response of UFH systems. Deep Reinforcement Learning (DRL) offers a data-driven control approach capable of simultaneously optimizing energy consumption and thermal comfort. However, the application of DRL-based controllers in occupied buildings under real operating conditions remains limited. This work presents and end-to-end case study (development, evaluation, and real-world deployment) of a DRL-based controller for an integrated UFH-HP system. First, a simulation-based pilot study was conducted to assess different DRL algorithms, control strategies, and configurations. Subsequently, a digital twin of a real residential building was developed and used to train DRL agents under simulated operating conditions. The best-performing agent was then deployed in the physical building without additional online fine-tuning. The results show that the controller successfully maintained indoor temperatures within the prescribed comfort limits while dynamically adjusting the HP supply temperature and UFH valve positions. These findings demonstrate the feasibility of deploying DRL controllers in occupied buildings and highlight their robustness and the practical challenges associated with transferring control policies from digital environments to real heating systems.

0.32

ADAPT: Physics-Aware Diffusion-based World Models for Adaptive Predictive Transferable HVAC Control

cs.AI ·2026-08-20 ·Xu Yang, Kailai Sun, Dianyu Zhong, Qianchuan Zhao
similarity 0.53
Abstract

Buildings account for roughly one-third of global energy consumption and CO$_2$ emissions. Optimizing indoor climate systems plays a critical role for urban climate mitigation aligned with UN Sustainable Development Goals 11 and 13. However, indoor delayed thermodynamic responses and partial observability severely hinder existing methods, which are primarily limited by implicit thermal inertia, occupancy dynamic prediction, and cumulative prediction errors, especially for out-of-distribution environments. In practice, these challenges are further exacerbated by the high cost and privacy burden of dense indoor sensing, forcing operators to collect only limited data in a single operating regime while expecting controllers to generalize reliably across unseen seasons and climate regions. To address this problem, we propose ADAPT, a physics-aware conditional diffusion indoor environmental world model for HVAC control. The model predicts a short-horizon held-action thermal baseline to capture the latent thermal inertia of the buildings. The diffusion backbone utilizes the robustness of generative models, while a learnable multi-zone heat-balance regularizer constrains generated trajectories to satisfy transferable building thermodynamics without requiring known building geometry or manually calibrated thermal parameters. A credit assignment is then design for the downstream reinforcement learning. Extensive experiments on SemibuildingSim and Sinergym demonstrate that ADAPT reduces HVAC energy consumption by 7.3\% and occupant discomfort by 30.2\% compared with state-of-the-art baselines under IID control. Under OOD control scenarios spanning unseen seasons and climate regions, ADAPT maintains robust performance with only marginal degradation relative to its IID performance, substantially outperforming existing methods in transfer robustness.

0.23