CS Paper Radar

Evaluation Principles for MRI-MRA Registration in Trigeminal Neuralgia: An ROI-Centered Neurovascular Benchmark

Xupeng Zhang, Xihang Wang, Michael Xie, Haoyuan Liang, Hau Ern Lien, Oishika Das, James Feghali, Risheng Xu, Peirong Liu

cs.CV ·submitted 2026-09-08 14:32 UTC · v1
benchmarkcode/data

Abstract

Preoperative evaluation of trigeminal neuralgia (TN) often requires joint interpretation of structural MRI, which depicts the trigeminal nerve and surrounding cisternal anatomy, and time-of-flight MRA, which highlights vascular structures. Although MRI-MRA fusion is clinically attractive for visualizing neurovascular compression, this task is poorly captured by conventional whole-brain registration evaluation because the clinically relevant target is a small trigeminal ROI, vessel annotations are partial and clinically focused, local TOF-MRA contrast is variable, and field-of-view mismatch can limit deformable alignment. We formulate TN MRI-MRA fusion as an ROI-centered neurovascular registration-evaluation problem and construct a benchmark from 149 patients with clinician-annotated bilateral trigeminal ROIs. Six representative registration pipelines were evaluated using local image-based metrics, segmentation-derived vessel-localization metrics, prediction-volume analysis, and contrast- and FOV-stratified comparisons. Conventional evaluation summaries were often misleading: local image similarity, vessel-background separability, and downstream vessel localization did not co-rank methods; one-sided vessel distances were strongly affected by predicted vessel extent under partial annotations; and local MRA contrast determined when vessel-separability metrics were informative. Deformable refinement provided only a small, FOV-dependent benefit over affine alignment, while reader review showed that locally favorable vessel distances could coexist with globally implausible registrations. These findings indicate that TN MRI-MRA registration should be evaluated as a local, vessel-aware, contrast-sensitive, and FOV-aware visualization task rather than as generic multimodal brain registration. Our code is publicly available at https://github.com/jhuldr/TN-Reg-Benchmark.

Comment
Includes supplementary material. Code: https://github.com/jhuldr/TN-Reg-Benchmark

Closest papers

Nearest neighbours by meaning across the whole index.

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data similarity 0.59
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.23

Interpretable Multimodal MRI-Clinical Fusion for Functional Outcome Prediction After Acute Ischemic Stroke

cs.LG cs.AIcs.CVeess.IV ·2026-11-05 ·Sina Raeisadigh, Henning Müller, Abderrahmane Hedjoudje
similarity 0.58
Abstract · 5 pages, 2 figures, 1 table

This study evaluates the added prognostic value of day-1 multimodal MRI for predicting three-month functional outcome after acute ischemic stroke (AIS). Sixty-six AIS patients with ADC, DWI, FLAIR, and clinical data were analyzed. Three-dimensional pretrained ResNet embeddings were extracted from each MRI modality, reduced using fold-isolated principal component analysis, and combined with structured clinical variables and ADC-derived lesion biomarkers. Linear support vector machines were evaluated using eight-fold stratified group cross-validation across MRI modality combinations. Clinical-only modeling achieved strong performance (AUC = $0.899 \pm 0.151$), while MRI-only models showed limited discrimination (AUC $\approx$ $0.67$-$0.73$). Among multimodal configurations, FLAIR-clinical fusion achieved the highest mean cross-validated performance (AUC = $0.948 \pm 0.061$), followed by ADC-clinical fusion (AUC = $0.941 \pm 0.094$). Full ADC-DWI-FLAIR fusion did not consistently outperform single-modality clinical fusion. Feature-importance analysis identified age, NIHSS subscores, ADC lesion burden, and learned FLAIR representations as key contributors, while qualitative FLAIR activation maps showed responses over lesion-like regions. These findings suggest that compact day-1 FLAIR and ADC representations provide complementary prognostic information beyond clinical variables and support interpretable, data-efficient outcome prediction in AIS.

0.16

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.58
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.57
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

eess.IV cs.CV ·2026-10-23 ·Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian +10 more
similarity 0.57
Abstract · 36 pages, 7 main figures, 2 supplementary figures. Under review at Medical Image Analysis

4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

0.21

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

cs.CV ·2026-08-19 ·Maedeh Hafezi Moghadas, Hakim Baazaoui, Lukas Bastian Otto, Susanne Wegener, Björn Menze +1 more
publishedcode/data similarity 0.57
Abstract · 11 pages, 3 figures, 1 table. Accepted at SWITCH+ 2026, a MICCAI 2026 workshop

Digital subtraction angiography (DSA) is the reference standard for leptomeningeal collateral (LMC) assessment, providing critical prognostic insights to guide secondary treatment strategies, neurorehabilitation planning, and retrospective stroke research. However, clinical LMC grading via the ASITN/SIR scale relies on manual, highly variable visual inspection. We introduce X-LMC, a spatiotemporal framework for automated collateral scoring from time-resolved biplane DSA. The proposed architecture encodes spatial frame representations through a DINOv2 backbone, fuses orthogonal projections via a token-level cross-view attention module, and models representations of contrast bolus dynamics using a recurrent network architecture. We evaluate our framework on a multicenter dataset of 134 patients with M1-segment occlusions. In a 5-fold cross-validation setting, X-LMC yields higher point estimates than static architectures and spatiotemporal baselines adapted from related angiographic tasks, achieving a Quadratic Weighted Kappa (QWK) of 0.398 (vs. 0.322) and a dichotomized macro-F1 score of 0.711 (vs. 0.663) against the best-performing baseline. X-LMC performance also aligns with the observed clinical inter-rater agreement (QWK: 0.314). As the first DSA study attempting to automate LMC scoring, we demonstrate that multi-view temporal deep learning can capture collateral-specific contrast kinetics. Ultimately, these benchmarks delineate the clinical ambiguities and achievable performance boundaries of automated ASITN/SIR grading, establishing a reproducible foundation for objective hemodynamic phenotyping in stroke cohorts. Code is available at https://github.com/maedehafezi/X-LMC.

0.45

A multicenter benchmark and clinically structured metric for coronary CTA report generation

cs.CV ·2026-09-01 ·Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu +5 more
benchmarkcode/data similarity 0.57
Abstract

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.

0.32

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

cs.CV physics.med-ph ·2026-10-25 ·Mojtaba Safari, Mingzhe Hu, Shansong Wang, Suyang Xi, Joshua Lorenz +4 more
code/data similarity 0.56
Abstract

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

0.24