CS Paper Radar

An Empirical Study of Development-Tuned Representation Sensitivity for Medical QA Data Selection

Yuexin Wu, Dayou Yu, Vasile Rus

cs.CL cs.AI ·submitted 2026-09-09 03:58 UTC · v2
published

Abstract

We study medical question-answering (QA) data selection when a developer already has questions, labels, and auxiliary explanatory texts but can retain only $B$ examples for a final LoRA update. Representation-Sensitivity Prioritization (RSP) first restricts the candidate bank to its top-$4B$ predictive-entropy examples, then combines the frequency of answer flips with non-flipping contraction of the top-two answer margin under hidden-state perturbations. We evaluate this operational score on five medical QA datasets with google/medgemma-4b-it, $B=128$, and three seed branches. After removing four MedExpQA test questions that also occur in its acquisition pool, dataset-specific development-tuned RSP attains the highest observed five-dataset mean accuracy (53.44%) and Macro-F1 (48.21%) among the evaluated selectors. Relative to random selection within the same entropy-restricted pool, the descriptive differences are +1.49 and +2.10 percentage points, respectively; paired 95% bootstrap intervals include zero. The audit mixes benchmarks with different relationships to documented backbone post-training sources, and the same test cohorts had been used in earlier analyses before the expanded tuning grid was designed. Results are therefore exploratory, modest, and dataset-dependent rather than evidence of statistical superiority. RSP point estimates also exceed an archived no-update reference, but unpinned model revisions and incomplete historical input identifiers limit attribution of that difference to fine-tuning. Because every selected training example includes auxiliary text and no matched answer-only control is evaluated, the experiments also do not identify a causal benefit from auxiliary-text conditioning itself.

Comment
16 pages. Substantially revised GenAI4Health @ NeurIPS 2026 version: updated title, development-tuned question-only selection protocol, experiments, and retrospective audit. Includes retained-artifact ancillary material

Closest papers

Nearest neighbours by meaning across the whole index.

Perturbation-Based Data Selection for Medical Question Answering

cs.CL ·2026-10-24 ·Yuexin Wu, Dayou Yu, Vasile Rus
similarity 0.85
Abstract · 10 pages. Preprint submitted to IEEE ICHI 2027. Extends the non-archival GenAI4Health @ NeurIPS 2026 study arXiv:2609.09684v2 with automatic…

Selecting a compact training subset is an important step in adapting medical language models from existing question-answering banks. We investigate perturbation-based data selection using two signals derived from Gaussian perturbations of the final-block representation: prediction-change frequency and non-flipping margin contraction. After a shared entropy prefilter, Representation-Sensitivity Prioritization (RSP) combines the signals using automatic root-mean-square scaling, while RSP-Drop ranks candidates by contraction alone. Both selectors use only questions and answer options during selection. We evaluate them with MedGemma-4B on five medical QA datasets at retained-set budgets of 64, 128, and 256 examples. At the primary budget of 128, RSP and RSP-Drop obtain dataset-averaged Macro-F1 scores of 47.55 and 48.28, respectively, compared with 45.11 for entropy-pool-matched random selection. Their relative performance varies across datasets and budgets. A selected-set case study identifies contrasting clean-margin profiles among the examples exchanged by the two rules, while a full-pool ablation shows that entropy prefiltering is not uniformly beneficial. These retrospective results characterize the empirical utility and limitations of perturbation-based selection under a fixed adaptation protocol. Evaluation uses one backbone and benchmarks with documented training-family overlap; it does not establish clinical effectiveness.

0.08

Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA

cs.CL cs.LG ·2026-09-01 ·Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
top venuebenchmarkcode/data similarity 0.67
Abstract · Accepted to EMNLP 2026 (Main Conference). 9 pages, 4 figures (main text); 28 pages total, including appendix. Code and data: https://github.…

Linear classifiers trained on hidden states of a large language model (LLM), linear probes, can flag factual errors from a single forward pass. Geometrically, that implies that true and false statements separate along a stable direction in hidden state space, i.e., the truth direction. Prior work disagrees on whether this generalises across input shifts, but the disagreement is hard to interpret because cross-dataset probe transfer experiments confound several kinds of input change at once. We isolate three such variables in medical question-answering (QA): writing style (register), domain (medical specialty), and corpus (dataset). We build a benchmark using 500 MedQA entries, each rewritten into four styles (textbook, patient, clinical note, colloquial), annotated with clinical specialty, and grouped with two other exam corpora, MedMCQA and MMLU-medical, for cross-dataset evaluation. Probing four open-weight LLMs (2--8B), we find that the truth direction is largely robust to writing style (mean $Δ_\text{register} \approx 0.10$ AUROC on held-out facts) and to medical specialty ($Δ_\text{specialty} \approx 0.03$), but degrades unevenly across corpora: by $0.12$ AUROC on MMLU-medical and by $0.21$ on MedMCQA, roughly twice the register gap. The register result replicates with a second generator and carries over to human-written patient questions. The truth direction is therefore largely stable within the medical domain but breaks under some corpus shifts, and question format does not explain the break, which suggests that the signal a linear probe recovers is partly bound to dataset structure rather than to medical knowledge alone.

0.60

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.64
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.09

Recursive LLM Degradation in Biomedical Question Answering: A Cross-Generation Study

cs.CL cs.LG ·2026-09-28 ·Bibek Bhandari, Kshitij Lingthep
similarity 0.64
Abstract · 6 pages, 2 figures, 1 table

Repeatedly training language models on their own generated data may create a synthetic-data feedback loop in which errors and distributional biases are reintroduced into subsequent training datasets. This paper studies that process in biomedical question answering (QA) using PubMedQA and two Qwen2.5 model sizes, 0.5B and 3B parameters. The study compares a recursive synthetic-data condition, in which generation G(k+1) is trained on answers produced by G(k), against a Human-Control condition that repeatedly uses the original human training data. The study evaluates across four generations from G0-G3 with two random seeds (42 and 123) and a fixed evaluation set of 1,000 expert-labeled samples. The evaluation includes disease and chemical entity F1, context-supported rate, lexical and semantic similarity, answer length, repetition rate, and other evaluation metrics. The Recursive condition for both model sizes and both seeds showed larger declines than the Human-Control condition in disease entity F1, chemical entity F1, context-supported rate, ROUGE-L, and cosine similarity. Under the fixed no-repeat 3-gram decoding constraint, the main observed behavioral change was increased answer length, while the measured 3-gram repetition rate did not increase. The magnitude of the difference-in-change was larger for the 3B model than for the 0.5B model. This difference was particularly apparent in disease F1, context-supported rate, cosine similarity, and answer length. These results show domain-specific changes associated with using recursive synthetic-data training in biomedical QA, but do not establish clinical hallucination rates or universal model collapse.

0.21

TrialJev: Open-Weight Single Pass Eligibility Scoring for Patient Trial Screening

cs.LG ·2026-11-06 ·Omar Ibrahim, Grant Hamblin, Benjamin Haibe-Kains
code/data similarity 0.64
Abstract · 38 pages. Code: https://github.com/oibrahi1/TrialJev. Models: https://huggingface.co/omareng/TrialJev

Clinical trial screening requires assessing large numbers of patient-trial pairs to prioritize candidates for detailed eligibility review, often under restrictions on sharing patient records. We introduce TrialJev, an open-weight eligibility scorer that uses LoRA-adapted Qwen models and a pointer head to score natural-language answer options in a single forward pass, without autoregressive decoding. Trained on TREC Clinical Trials 2021 and evaluated on 6,975 eligible-or-excluded pairs from 50 unseen TREC 2022 synthetic patients, TrialJev achieves 80.97% (Qwen3.5-27B) and 81.84% (Qwen3.8-27B) accuracy, compared with 79.87% and 79.93% for LLMs fine-tuned on the same data to generate verdicts. In matched batch-1 measurements, verdict generation takes 2.45-2.70 times as long as the one-pass inference of TrialJev at 9B-27B. Under a common development-fitted decision correction, the two 27B TrialJev models reach 80.99% and 81.88% accuracy, compared with 81.28% for the proprietary hosted Jev API; paired confidence intervals include zero. TrialJev runs locally on a single GPU, requiring approximately 178 ms per pair at 27B, without transmitting patient text to an external model API. An A/B-logit ablation shows that avoiding decoding, rather than the pointer head alone, accounts for the measured efficiency advantage. TrialJev is intended for first-pass prioritization of candidate trials, complementing rather than replacing explanatory models and clinical review. Evaluation is limited to synthetic patients and implementation-specific timing, and clinical use has not been validated. Adapters, pointer heads, and model cards are released on Hugging Face.

0.22

Safety-Preserving Medical LLM Fine-Tuning via Bilevel Data Selection

cs.CL cs.AIcs.LG ·2026-11-16 ·Ruoxuan Shi, Sheng Yang, Zhengxing Su, Xiaoyang Hou, Yating Liu
similarity 0.64
Abstract

As general large language models (LLMs) are increasingly adapted for patient-facing medical applications, improving medical capability while controlling patient-facing risks remains a critical challenge. Large-scale medical instruction data are essential for acquiring domain knowledge through supervised fine-tuning (SFT), but unsafe responses can undermine existing safety alignment. To address this problem, we propose Scalable Bilevel Data Selection (S-BDS) for safety-preserving medical SFT. By controlling selection-weight concentration, S-BDS enables reliable sample ranking over large candidate pools and identifies training examples that improve medical capability while controlling patient-facing risks. We combine clinician-validated safe data and selected data with unscreened medical instruction data for SFT, and jointly evaluate medical capability and patient-facing safety on HealthBench and PatientSafetyBench, respectively. Experiments across Llama and Qwen models show that S-BDS achieves the highest safe rates among all compared methods, outperforming the strongest baselines by 4.64 and 3.00 percentage points, respectively, while maintaining competitive medical capability. Further experiments show that varying the safety-oriented weight during SFT controls the trade-off between medical capability and patient-facing safety.

0.15

Option-Aware Retrieval and Task-Specific VLM Adaptation for Medical VQA

cs.AI cs.CLcs.CV ·2026-09-14 ·Tristan Kirscher, Niklas C. Koser, Soren Pirk
top venue similarity 0.63
Abstract

We describe our submission to the MedReason 2026 challenge, covering multiple-choice (MCQ) and open-ended (OE) medical visual question answering (VQA) under fully offline, containerized inference. Our first finding is that MCQ retrieval must compare answer \emph{semantics} rather than answer labels: labels are independently assigned per question, so copying a retrieved neighbor's label transfers no useful information, whereas scoring each current option's text against correct-answer text from similar training cases raises retrieval-only accuracy from 20.0\% to 57.5\% on a 200-case retrieval-excluded development holdout. Our second finding attributes the submitted system's accuracy: holding the task-specific MCQ Low-Rank Adaptation (LoRA) adapter fixed and varying the number \(k\) of in-prompt retrieved examples changes accuracy by at most one case --- 187/200 (93.5\%) at both \(k=0\) and the adapter's training-time \(k=1\), 188/200 (94.0\%) at the packaged runtime's default \(k=3\) --- and the submitted confidence-gated override adds no net accuracy on top of \(k=3\), selecting the VLM in 198/200 cases. With the final MCQ adapter fixed, retrieval changes accuracy by at most one case, and gating provides no net gain. On 20 OE cases, token-F1 and RaTEScore~\cite{zhao2024ratescore} decrease as \(k\) grows, but paired sign tests on token-F1 differences are nonsignificant (\(p \ge 0.29\)); a single-annotator comparison found 6/20 wrong-anchor errors for the final configuration and 14/20 for an earlier configuration that jointly differed in routing, adapter, and prompting. The system reaches 94.0\% MCQ accuracy on the development holdout and 93.20\% on the organizer's official pre-evaluation, versus 29.43\% for the off-the-shelf reference baseline, while both of the organizer's open-ended scores are lower than that baseline's (ground-truth agreement 1.245 versus 1.588, visual accuracy 1.995 versus 2.696, each out of 4).

0.31

Beyond Information Seeking: Severity-Aware Question Supervision for Proactive Medical Dialogue

cs.CL ·2026-08-25 ·Chenxuan Li, Xinrong Chen, Luyan Zhang, Peidong Jia, Runfan Zheng +3 more
similarity 0.63
Abstract · 5 pages, 2 figures, 2 tables. Submitted to ICASSP 2027. Updated author list and manuscript

Proactive medical dialogue requires an agent to decide what to ask from incomplete patient information. Existing information-seeking approaches commonly prioritize questions that most reduce diagnostic uncertainty, but this criterion overlooks an important property of medical diagnosis: different diagnostic errors can carry substantially different consequences. The most informative question may therefore differ from the one most valuable for the downstream decision. We propose Expected-Severity-Risk (ESR), a consequence-aware question-supervision objective that values each candidate by its expected reduction in severity-aware terminal risk. Because questions must be selected before their answers are observed, ESR marginalizes over possible answers using train-only population statistics. Its rankings are then distilled into a prefix-only language policy, requiring no teacher-side risk computation at deployment. Across three matched Qwen3-4B training seeds on DDxPlus, ESR reduces mean high-severity diagnostic miss from 0.0645 to 0.0455 (29.5% relative reduction) and improves mean diagnostic accuracy from 0.9123 to 0.9320 while requiring only 0.14 additional questions per dialogue. Fixed-budget analyses show that the distinction persists when question count is controlled, while a matched expected-0/1-risk student control further isolates the contribution of asymmetric severity weighting. These results support moving proactive medical dialogue beyond uncertainty reduction toward consequence-aware evidence acquisition.

0.23