CS Paper Radar

Perturbation-Based Data Selection for Medical Question Answering

Yuexin Wu, Dayou Yu, Vasile Rus

cs.CL ·submitted 2026-10-24 04:33 UTC · v1

Abstract

Selecting a compact training subset is an important step in adapting medical language models from existing question-answering banks. We investigate perturbation-based data selection using two signals derived from Gaussian perturbations of the final-block representation: prediction-change frequency and non-flipping margin contraction. After a shared entropy prefilter, Representation-Sensitivity Prioritization (RSP) combines the signals using automatic root-mean-square scaling, while RSP-Drop ranks candidates by contraction alone. Both selectors use only questions and answer options during selection. We evaluate them with MedGemma-4B on five medical QA datasets at retained-set budgets of 64, 128, and 256 examples. At the primary budget of 128, RSP and RSP-Drop obtain dataset-averaged Macro-F1 scores of 47.55 and 48.28, respectively, compared with 45.11 for entropy-pool-matched random selection. Their relative performance varies across datasets and budgets. A selected-set case study identifies contrasting clean-margin profiles among the examples exchanged by the two rules, while a full-pool ablation shows that entropy prefiltering is not uniformly beneficial. These retrospective results characterize the empirical utility and limitations of perturbation-based selection under a fixed adaptation protocol. Evaluation uses one backbone and benchmarks with documented training-family overlap; it does not establish clinical effectiveness.

Comment
10 pages. Preprint submitted to IEEE ICHI 2027. Extends the non-archival GenAI4Health @ NeurIPS 2026 study arXiv:2609.09684v2 with automatic RMS scaling, RSP-Drop, budget analyses, and entropy-prefilter ablations

Closest papers

Nearest neighbours by meaning across the whole index.

An Empirical Study of Development-Tuned Representation Sensitivity for Medical QA Data Selection

cs.CL cs.AI ·2026-09-09 ·Yuexin Wu, Dayou Yu, Vasile Rus
published similarity 0.85
Abstract · 16 pages. Substantially revised GenAI4Health @ NeurIPS 2026 version: updated title, development-tuned question-only selection protocol, expe…

We study medical question-answering (QA) data selection when a developer already has questions, labels, and auxiliary explanatory texts but can retain only $B$ examples for a final LoRA update. Representation-Sensitivity Prioritization (RSP) first restricts the candidate bank to its top-$4B$ predictive-entropy examples, then combines the frequency of answer flips with non-flipping contraction of the top-two answer margin under hidden-state perturbations. We evaluate this operational score on five medical QA datasets with google/medgemma-4b-it, $B=128$, and three seed branches. After removing four MedExpQA test questions that also occur in its acquisition pool, dataset-specific development-tuned RSP attains the highest observed five-dataset mean accuracy (53.44%) and Macro-F1 (48.21%) among the evaluated selectors. Relative to random selection within the same entropy-restricted pool, the descriptive differences are +1.49 and +2.10 percentage points, respectively; paired 95% bootstrap intervals include zero. The audit mixes benchmarks with different relationships to documented backbone post-training sources, and the same test cohorts had been used in earlier analyses before the expanded tuning grid was designed. Results are therefore exploratory, modest, and dataset-dependent rather than evidence of statistical superiority. RSP point estimates also exceed an archived no-update reference, but unpinned model revisions and incomplete historical input identifiers limit attribution of that difference to fine-tuning. Because every selected training example includes auxiliary text and no matched answer-only control is evaluated, the experiments also do not identify a causal benefit from auxiliary-text conditioning itself.

0.59

Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA

cs.CL cs.LG ·2026-09-01 ·Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
top venuebenchmarkcode/data similarity 0.66
Abstract · Accepted to EMNLP 2026 (Main Conference). 9 pages, 4 figures (main text); 28 pages total, including appendix. Code and data: https://github.…

Linear classifiers trained on hidden states of a large language model (LLM), linear probes, can flag factual errors from a single forward pass. Geometrically, that implies that true and false statements separate along a stable direction in hidden state space, i.e., the truth direction. Prior work disagrees on whether this generalises across input shifts, but the disagreement is hard to interpret because cross-dataset probe transfer experiments confound several kinds of input change at once. We isolate three such variables in medical question-answering (QA): writing style (register), domain (medical specialty), and corpus (dataset). We build a benchmark using 500 MedQA entries, each rewritten into four styles (textbook, patient, clinical note, colloquial), annotated with clinical specialty, and grouped with two other exam corpora, MedMCQA and MMLU-medical, for cross-dataset evaluation. Probing four open-weight LLMs (2--8B), we find that the truth direction is largely robust to writing style (mean $Δ_\text{register} \approx 0.10$ AUROC on held-out facts) and to medical specialty ($Δ_\text{specialty} \approx 0.03$), but degrades unevenly across corpora: by $0.12$ AUROC on MMLU-medical and by $0.21$ on MedMCQA, roughly twice the register gap. The register result replicates with a second generator and carries over to human-written patient questions. The truth direction is therefore largely stable within the medical domain but breaks under some corpus shifts, and question format does not explain the break, which suggests that the signal a linear probe recovers is partly bound to dataset structure rather than to medical knowledge alone.

0.60

Route, Don't Fix: Regime-Dependent Decoding Correction and a Trajectory-Gated Router for Reliable Clinical LLM Answer Selection

cs.CL cs.AIcs.LG ·2026-09-13 ·Zeyu Dong, Benjamin Wang, Joyee W. Jin
similarity 0.64
Abstract

Large language models (LLMs) are often deemed unsafe for clinical question answering because of their tendency to hallucinate. Retrieval augmentation, fine-tuning, and external verifiers require new infrastructure that clinical governance must approve and may add latency or extra model calls. Inference-time correction uses the model's internal logit signals, but a fixed transformation need not suit every question. A corrector that improves accuracy by about ten percentage points on a truthfulness stress test yields negligible gains on clinical multiple-choice benchmarks, where instruction tuning concentrates output probability on one answer and leaves low terminal entropy. We introduce ALTAS, which reads terminal entropy and late-layer linearity ($R^2$) from one forward pass to choose per question between greedy decoding and late-layer trajectory correction. No classifier, probe, or head is trained; the router operates on candidate-answer logits and adds 6.5% latency overhead. Applied to every question, the correction improves TruthfulQA over greedy at 3B and 8B by 11.4 and 10.0 percentage points, respectively ($p<10^{-10}$). Gated per question, ALTAS retains gains of 8.3 to 9.5 percentage points while keeping MedQA, PubMedQA, and MedHallu within a one-percentage-point do-no-harm band, with no statistically significant differences from greedy. The method passes verification sweeps over frozen thresholds, the scoring rule, and the domain label.

0.21

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.64
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.09

Recursive LLM Degradation in Biomedical Question Answering: A Cross-Generation Study

cs.CL cs.LG ·2026-09-28 ·Bibek Bhandari, Kshitij Lingthep
similarity 0.63
Abstract · 6 pages, 2 figures, 1 table

Repeatedly training language models on their own generated data may create a synthetic-data feedback loop in which errors and distributional biases are reintroduced into subsequent training datasets. This paper studies that process in biomedical question answering (QA) using PubMedQA and two Qwen2.5 model sizes, 0.5B and 3B parameters. The study compares a recursive synthetic-data condition, in which generation G(k+1) is trained on answers produced by G(k), against a Human-Control condition that repeatedly uses the original human training data. The study evaluates across four generations from G0-G3 with two random seeds (42 and 123) and a fixed evaluation set of 1,000 expert-labeled samples. The evaluation includes disease and chemical entity F1, context-supported rate, lexical and semantic similarity, answer length, repetition rate, and other evaluation metrics. The Recursive condition for both model sizes and both seeds showed larger declines than the Human-Control condition in disease entity F1, chemical entity F1, context-supported rate, ROUGE-L, and cosine similarity. Under the fixed no-repeat 3-gram decoding constraint, the main observed behavioral change was increased answer length, while the measured 3-gram repetition rate did not increase. The magnitude of the difference-in-change was larger for the 3B model than for the 0.5B model. This difference was particularly apparent in disease F1, context-supported rate, cosine similarity, and answer length. These results show domain-specific changes associated with using recursive synthetic-data training in biomedical QA, but do not establish clinical hallucination rates or universal model collapse.

0.21

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.61
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

Benchmarking decision models against generative large language models on medical multiple-choice questions

cs.CL cs.AI ·2026-10-28 ·Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert +1 more
similarity 0.61
Abstract

Medical workflows often require selecting among predefined options. We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions. Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations. Among the tested configurations, Mercury Decide had the lowest mean final-attempt cost (USD 0.0069 per 1,000 questions), while Clef Omni had the shortest median request duration (0.291 seconds). Decision-model probabilities distinguished correct from incorrect answers, but error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied. Decision models offered resource advantages alongside lower peak accuracy; selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.

0.22

A general-purpose System One decision model for clinical records

cs.AI ·2026-10-19 ·Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner, Dongmin Bang, Tong Ding +12 more
similarity 0.61
Abstract

Clinical care, health-system operations and biomedical discovery depend on extracting reliable answers from patient records, yet applying diverse clinical questions across entire populations remains computationally expensive. Here we present Clinical System One (CS1), a 4-billion-parameter decision model for fast, typed judgments from clinical records, along with two agentic harnesses in which CS1 works together with a generalist language model. CS1-4B is trained on 12.4 million questions and answers from 3.6 million patients across a multi-hospital health system, combining structured-data keys, observed outcomes and language-model supervision across clinical notes, diagnostic reports and patient timelines. It answers multiple typed questions in a single forward pass without task-specific retraining, and each answer carries a probability that can route uncertain cases to human review. On 963,408 held-out patients, CS1-4B outperformed open decision models up to 27 billion parameters on 13 of 14 tasks scored independently of its training teacher. Across 21 external data sets, its aggregate performance approached that of the strongest tested 27-billion-parameter model, with 6.4-fold faster inference in a matched workload. Integrating CS1-4B with a language model agent produced cited answers over complete multi-year patient histories and screened a patient population against the eligibility criteria of 17 registered clinical trials, placing four times as many judged-eligible patients among its top 20 candidates as keyword search while using 690-fold fewer language-model tokens than a language model reading every record. These findings support a division of labour in clinical AI, with small decision models performing repeated record reading and generative models formulating questions and synthesizing evidence.

0.42