CS Paper Radar

Streaming P300 Acquisition and Statistical Signal Validation Across Five EEG Platforms: A Hardware-Agnostic BrainFlow/LSL Pipeline

Isabella Guan, Rui Liu, Fusheng Wang

cs.HC ·submitted 2026-09-09 11:22 UTC · v1

Abstract

P300 spellers offer people with severe motor impairment, such as ALS, an effective communication channel and remain one of the most established surgery-free alternatives to intracortical interfaces. Advanced language models have made spellers faster and more robust, yet the hardware beneath them is under-studied. We present a hardware-agnostic, real-time P300 acquisition pipeline built on BrainFlow and Lab Streaming Layer (LSL) that runs unchanged across consumer- and research-grade EEG headsets, with permutation tests of signal separability. Using a standard 6 x 6 row/column paradigm, we piloted five configurations: a custom dry system, a custom wet/gel system, Emotiv Flex, Emotiv EPOC X, and Muse 2. The custom systems and EPOC X showed weak or inconsistent signal separability, Muse 2 had the highest acquisition reliability despite limited centro-parietal coverage, and Flex showed the most promising signal. In 20 further Flex sessions varying subject, timing, and phrase length (131 target characters), a peak-amplitude permutation test and a cross-validated xDAWN decoder both detected a significant target response under two channel-exclusion policies, with decoder AUC reaching about 0.72 after 15 repetitions. Character accuracy depended heavily on evaluation methodology: in-sample majority voting reached 94.7%, whereas character-held-out accuracy was 31.3% with evidence accumulated across repetitions, about three times that of held-out majority voting. These analyses indicate that Flex captured a detectable, if still weak, P300 under the studied conditions, while broader participant-level validation and improved decoding remain necessary.

Closest papers

Nearest neighbours by meaning across the whole index.

When More Is Not Better: Component Anti-Synergy in a P300 Speller

cs.LG ·2026-09-10 ·Lucas Yang, Rui Liu, Fusheng Wang
similarity 0.71
Abstract

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

0.18

How large an effect would we have seen? Positive controls, detection floors and dataset pitfalls in scalp-EEG speech decoding

eess.SP q-bio.NCq-bio.QM ·2026-10-14 ·Blessing Isoyiza Adeika, Onyema Osuagwu
similarity 0.64
Abstract · 22 pages, 4 figures, 8 tables plus supplementary tables. To be submitted to Journal of Neural Engineering

Objective. Studies that decode imagined speech from scalp electroencephalography (EEG) commonly validate their pipelines with a positive control, usually overt speech, and report null results without stating what effect size the pipeline could have detected. Approach. Using ds003626 ("Thinking out loud"), KaraOne and Track 3 of the 2020 International Brain-Computer Interface Competition, we audited decoding of overt speech, articulator preparation and imagined speech with artifact-channel subsets, band-limited decoding and trial selection, under a protocol that enforces split integrity by assertion. We injected class-dependent effects of known amplitude into the real recordings to measure the detection floor of five decoder families, and we checked the ds003626 labels against the dataset's acquisition protocol. Main results. On ds003626, two lip electrodes decoded overt speech at 0.7430 and the eight external channels at 0.7068, against 0.4231 for the 128-channel scalp montage, and no decodable signal survived in the 8-30 Hz band. On the other two corpora, within-subject accuracy rose monotonically with frequency into the range dominated by muscle activity. Band-power logistic regression detected an injected 8-30 Hz desynchronization of 0.54 uV under a criterion fixed in advance, whereas a compact convolutional network (EEGNet) detected nothing within subject up to 4.31 uV. In ds003626, the condition codes are the reverse of the intuitive reading, the class encoding changed between public releases, and condition is a deterministic function of time within each session. Significance. In these corpora the overt-speech positive control is dominated by myogenic signal and cannot validate a decoding pipeline. We recommend that speech-decoding studies report band-limited and artifact-channel accuracy, the direction of accuracy across frequency, and a measured detection floor.

0.39

Nimbus Studio reproduces reference BCI decoding pipelines: a validation study on public benchmarks across protocols and paradigms

cs.HC ·2026-10-09 ·Sergey Musienko
benchmark similarity 0.60
Abstract · 6 pages. Platform: https://studio.nimbusbci.com/

Nimbus Studio is a visual pipeline platform for brain-computer interface (BCI) experiments: researchers assemble preprocessing, feature extraction, decoding, and evaluation over public benchmark datasets or their own recordings, with cross-validated evaluation protocols (including leave-one-subject-out), BIDS export, and bring-your-own Python model classes. Whether its numbers can be trusted is a fair question for any such platform. We answer it with a parity study: six standard BCI decoding pipelines (CSP+LDA, Riemannian MDM, tangent-space logistic regression through the platform's bring-your-own-code node, P300 xDAWN+LDA, and the deep ShallowConvNet and EEGNet) were evaluated on three public datasets (motor-imagery BNCI-2014-001/004; P300 BNCI-2014-009) under two protocols (per-subject session holdout and pooled leave-one-subject-out cross-validation via the platform's planned-CV driver), once through Nimbus Studio's execution engine and once through independent, hand-written reference implementations built directly on MNE-Python, scikit-learn, pyriemann, and braindecode. Every deterministic pipeline matched the reference exactly (0.00 points maximum difference across all 54 session-holdout subject-runs and all CSP/MDM grouped-CV folds), including pipelines through the bring-your-own-code node and the CV orchestration; the remaining grouped-CV cells agree to floating-point precision (worst case 0.06 points, about one trial per fold). The stochastic deep models agreed within seed-to-seed training variability, estimated with multi-seed reruns on each side. The platform's execution engine therefore computes the same science as the reference stack across protocols, paradigms, and extensibility surfaces. The platform is available at https://studio.nimbusbci.com/, and the complete harness and per-subject results accompany this paper for independent verification.

0.15

Cross-subject decoding of imagined speech from scalp EEG: a leakage-controlled evaluation on three public corpora

eess.SP cs.LGq-bio.NC ·2026-10-14 ·Blessing Isoyiza Adeika, Onyema Osuagwu
similarity 0.60
Abstract · 23 pages, 5 figures, 10 tables plus supplementary tables. To be submitted to Journal of Neural Engineering

Objective. A decoder of imagined speech that works for a new user without calibration would make a non-invasive speech interface practical. We tested whether imagined-speech content recorded with scalp electroencephalography (EEG) transfers across people, and examined why accuracy within a single person remains low. Approach. We analyzed three public corpora, ds003626, KaraOne and Track 3 of the 2020 International Brain-Computer Interface Competition, under a protocol that enforces split integrity by assertion and reports exact binomial thresholds, group tests and bootstrap confidence intervals. We trained decoders on each participant and tested them on every other, compared representational geometry across participants without a classifier, applied subject-level alignment, and tested five explanations for the within-subject ceiling. Main results. Across 482 ordered pairs of participants, no pair survived correction for multiple comparisons; mean pair-transfer accuracy lay within 0.006 of chance on every corpus, while every within-subject reference lay above it. Imagery against pre-stimulus rest generalized at about 0.61 after artifact and elapsed-time controls, but its decoder labelled the interval preceding imagery as imagery as often as imagery itself, so the contrast reflects a post-stimulus state, not imagery. Within subject, only the competition corpus decoded above threshold for every participant (0.3147; chance 0.200); syllable count explained little of this, but its frequency profile failed an artifact audit. Significance. In these corpora, imagined-speech content did not transfer between people through any representation we examined. Trial count per class was the only variable that ordered the corpora, which favors larger single-condition datasets over further model development.

0.34

A Compact xDAWN-Guided Spatio-Temporal Network with Filter-Bank Convolution for P300 Detection

cs.HC cs.AI ·2026-11-12 ·Mohammad Mahdi Habibi Bina, Mohammad Reza Daliri
similarity 0.60
Abstract

P300-based brain-computer interfaces (BCIs) enable communication by decoding stimulus-evoked EEG responses into character selections without requiring voluntary motor output. Reliable P300 detection remains difficult because of low response amplitude and signal-to-noise ratio, while practical spellers require accurate character selection with few stimulus repetitions and low computational cost. We propose a compact deep learning architecture that combines xDAWN spatial filtering for event-related potential enhancement and dimensionality reduction, a fixed frequency-selective filter bank, and convolutional feature learning for spatio-temporal EEG decoding. Depthwise-separable convolutions and progressive average pooling reduce computational complexity while retaining discriminative temporal information. The resulting target/non-target classifier contains only 5,100 trainable parameters. We evaluated the model on two public benchmarks, BCI Competition II Dataset IIb and BCI Competition III Dataset II, and compared it with established P300 decoding methods across different numbers of stimulus repetitions. The model achieved an information transfer rate of 17.8 bits/min with two repetitions on BCI Competition III and 40.5 bits/min on BCI Competition II, demonstrating a favorable accuracy-speed trade-off. These results suggest that combining domain-informed spatial and spectral priors with compact neural networks can support efficient P300 decoding for EEG-based BCI communication.

0.24

Virtual iEEG from Scalp EEG: Charting the Landscape of Source Imaging, Intracranial Inference and Reconstruction

cs.CV ·2026-08-27 ·Dongyi He, Xiangkai Wang, Hongjie Yan, Luping Song, Wai Ting Siok +1 more
similarity 0.59
Abstract

Intracranial electroencephalography (iEEG) provides temporally precise and spatially specific access to neural activity from focal and deep brain regions, but its invasiveness and restricted anatomical coverage limit routine use. These constraints have motivated scalp-to-intracranial inference, termed virtual iEEG when model outputs carry iEEG-defined event, feature, representation, or contact-level waveform semantics. This review presents a target-centred framework distinguishing event inference, feature translation, and waveform reconstruction, while separating predictability from observability, identifiability, fidelity, and utility. Evidence is evaluated according to cohort independence, anatomical and spectral coverage, train--test separation, and target-patient adaptation. Current studies support inference of selected intracranial events, low-frequency components, and task-related representations, but not unique recovery of arbitrary contact-level activity. Stronger validation requires appropriate controls, source-imaging baselines, uncertainty assessment, and incremental-utility testing. Future progress depends on independent paired datasets and prospective evidence that virtual iEEG adds value beyond scalp EEG and EEG source imaging.

0.22

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.59
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

Inner-Speech Decoding from EEG Across Three Corpora Under a Fixed Architecture and Protocol

cs.AI cs.LGeess.SP ·2026-11-01 ·Md Wahiduzzaman Suva, Md Imtiaj Alam Sajin, Esm E Moula Chowdhury Abha, Susham Moula Choudhury Akash, Md Tauhidul Islam +3 more
benchmarkdataset similarity 0.58
Abstract

Inner-speech decoding from electroencephalography could support non-invasive communication for people with severe motor impairment, but comparison across studies is hindered by dataset- and protocol-specific evaluation. We present a controlled cross-dataset study using one preprocessing pipeline, one within-subject five-fold cross-validation protocol, and a compact dual-attention Transformer (VC-DATNet; approximately 131,000 parameters) across three public corpora: Thinking Out Loud (10 participants), BISpeech (4), and SyncSpeech (3). VC-DATNet achieved per-participant sensor/source hybrid accuracies of 39.48% on the four-class Thinking Out Loud task, 20.60% on the eight-word BISpeech task, and 25.53% on the eight-word SyncSpeech task, for which we report the first decoding result. Sensor-space and cortical source-space representations were complementary, with each performing better for different participants; this pattern replicated across all three corpora and nine architectures. Moreover, ten decoders spanning convolutional, recurrent, temporal-convolutional, hybrid Transformer, and pretrained foundation-model families converged within a narrow accuracy range on every dataset. These findings indicate that representation choice should be individualized and suggest that performance on these public corpora is constrained more by signal quality and dataset scale than by model capacity. The released pipeline provides a reproducible benchmark for future inner-speech decoding studies

0.07