Abstract

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

Closest papers

Nearest neighbours by meaning across the whole index.

Streaming P300 Acquisition and Statistical Signal Validation Across Five EEG Platforms: A Hardware-Agnostic BrainFlow/LSL Pipeline

cs.HC ·2026-09-09 ·Isabella Guan, Rui Liu, Fusheng Wang
similarity 0.71
Abstract

P300 spellers offer people with severe motor impairment, such as ALS, an effective communication channel and remain one of the most established surgery-free alternatives to intracortical interfaces. Advanced language models have made spellers faster and more robust, yet the hardware beneath them is under-studied. We present a hardware-agnostic, real-time P300 acquisition pipeline built on BrainFlow and Lab Streaming Layer (LSL) that runs unchanged across consumer- and research-grade EEG headsets, with permutation tests of signal separability. Using a standard 6 x 6 row/column paradigm, we piloted five configurations: a custom dry system, a custom wet/gel system, Emotiv Flex, Emotiv EPOC X, and Muse 2. The custom systems and EPOC X showed weak or inconsistent signal separability, Muse 2 had the highest acquisition reliability despite limited centro-parietal coverage, and Flex showed the most promising signal. In 20 further Flex sessions varying subject, timing, and phrase length (131 target characters), a peak-amplitude permutation test and a cross-validated xDAWN decoder both detected a significant target response under two channel-exclusion policies, with decoder AUC reaching about 0.72 after 15 repetitions. Character accuracy depended heavily on evaluation methodology: in-sample majority voting reached 94.7%, whereas character-held-out accuracy was 31.3% with evidence accumulated across repetitions, about three times that of held-out majority voting. These analyses indicate that Flex captured a detectable, if still weak, P300 under the studied conditions, while broader participant-level validation and improved decoding remain necessary.

0.32

A Compact xDAWN-Guided Spatio-Temporal Network with Filter-Bank Convolution for P300 Detection

cs.HC cs.AI ·2026-11-12 ·Mohammad Mahdi Habibi Bina, Mohammad Reza Daliri
similarity 0.59
Abstract

P300-based brain-computer interfaces (BCIs) enable communication by decoding stimulus-evoked EEG responses into character selections without requiring voluntary motor output. Reliable P300 detection remains difficult because of low response amplitude and signal-to-noise ratio, while practical spellers require accurate character selection with few stimulus repetitions and low computational cost. We propose a compact deep learning architecture that combines xDAWN spatial filtering for event-related potential enhancement and dimensionality reduction, a fixed frequency-selective filter bank, and convolutional feature learning for spatio-temporal EEG decoding. Depthwise-separable convolutions and progressive average pooling reduce computational complexity while retaining discriminative temporal information. The resulting target/non-target classifier contains only 5,100 trainable parameters. We evaluated the model on two public benchmarks, BCI Competition II Dataset IIb and BCI Competition III Dataset II, and compared it with established P300 decoding methods across different numbers of stimulus repetitions. The model achieved an information transfer rate of 17.8 bits/min with two repetitions on BCI Competition III and 40.5 bits/min on BCI Competition II, demonstrating a favorable accuracy-speed trade-off. These results suggest that combining domain-informed spatial and spectral priors with compact neural networks can support efficient P300 decoding for EEG-based BCI communication.

0.24

Cross-subject decoding of imagined speech from scalp EEG: a leakage-controlled evaluation on three public corpora

eess.SP cs.LGq-bio.NC ·2026-10-14 ·Blessing Isoyiza Adeika, Onyema Osuagwu
similarity 0.57
Abstract · 23 pages, 5 figures, 10 tables plus supplementary tables. To be submitted to Journal of Neural Engineering

Objective. A decoder of imagined speech that works for a new user without calibration would make a non-invasive speech interface practical. We tested whether imagined-speech content recorded with scalp electroencephalography (EEG) transfers across people, and examined why accuracy within a single person remains low. Approach. We analyzed three public corpora, ds003626, KaraOne and Track 3 of the 2020 International Brain-Computer Interface Competition, under a protocol that enforces split integrity by assertion and reports exact binomial thresholds, group tests and bootstrap confidence intervals. We trained decoders on each participant and tested them on every other, compared representational geometry across participants without a classifier, applied subject-level alignment, and tested five explanations for the within-subject ceiling. Main results. Across 482 ordered pairs of participants, no pair survived correction for multiple comparisons; mean pair-transfer accuracy lay within 0.006 of chance on every corpus, while every within-subject reference lay above it. Imagery against pre-stimulus rest generalized at about 0.61 after artifact and elapsed-time controls, but its decoder labelled the interval preceding imagery as imagery as often as imagery itself, so the contrast reflects a post-stimulus state, not imagery. Within subject, only the competition corpus decoded above threshold for every participant (0.3147; chance 0.200); syllable count explained little of this, but its frequency profile failed an artifact audit. Significance. In these corpora, imagined-speech content did not transfer between people through any representation we examined. Trial count per class was the only variable that ordered the corpora, which favors larger single-condition datasets over further model development.

0.34

Inner-Speech Decoding from EEG Across Three Corpora Under a Fixed Architecture and Protocol

cs.AI cs.LGeess.SP ·2026-11-01 ·Md Wahiduzzaman Suva, Md Imtiaj Alam Sajin, Esm E Moula Chowdhury Abha, Susham Moula Choudhury Akash, Md Tauhidul Islam +3 more
benchmarkdataset similarity 0.57
Abstract

Inner-speech decoding from electroencephalography could support non-invasive communication for people with severe motor impairment, but comparison across studies is hindered by dataset- and protocol-specific evaluation. We present a controlled cross-dataset study using one preprocessing pipeline, one within-subject five-fold cross-validation protocol, and a compact dual-attention Transformer (VC-DATNet; approximately 131,000 parameters) across three public corpora: Thinking Out Loud (10 participants), BISpeech (4), and SyncSpeech (3). VC-DATNet achieved per-participant sensor/source hybrid accuracies of 39.48% on the four-class Thinking Out Loud task, 20.60% on the eight-word BISpeech task, and 25.53% on the eight-word SyncSpeech task, for which we report the first decoding result. Sensor-space and cortical source-space representations were complementary, with each performing better for different participants; this pattern replicated across all three corpora and nine architectures. Moreover, ten decoders spanning convolutional, recurrent, temporal-convolutional, hybrid Transformer, and pretrained foundation-model families converged within a narrow accuracy range on every dataset. These findings indicate that representation choice should be individualized and suggest that performance on these public corpora is constrained more by signal quality and dataset scale than by model capacity. The released pipeline provides a reproducible benchmark for future inner-speech decoding studies

0.07

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.57
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

Nimbus Studio reproduces reference BCI decoding pipelines: a validation study on public benchmarks across protocols and paradigms

cs.HC ·2026-10-09 ·Sergey Musienko
benchmark similarity 0.56
Abstract · 6 pages. Platform: https://studio.nimbusbci.com/

Nimbus Studio is a visual pipeline platform for brain-computer interface (BCI) experiments: researchers assemble preprocessing, feature extraction, decoding, and evaluation over public benchmark datasets or their own recordings, with cross-validated evaluation protocols (including leave-one-subject-out), BIDS export, and bring-your-own Python model classes. Whether its numbers can be trusted is a fair question for any such platform. We answer it with a parity study: six standard BCI decoding pipelines (CSP+LDA, Riemannian MDM, tangent-space logistic regression through the platform's bring-your-own-code node, P300 xDAWN+LDA, and the deep ShallowConvNet and EEGNet) were evaluated on three public datasets (motor-imagery BNCI-2014-001/004; P300 BNCI-2014-009) under two protocols (per-subject session holdout and pooled leave-one-subject-out cross-validation via the platform's planned-CV driver), once through Nimbus Studio's execution engine and once through independent, hand-written reference implementations built directly on MNE-Python, scikit-learn, pyriemann, and braindecode. Every deterministic pipeline matched the reference exactly (0.00 points maximum difference across all 54 session-holdout subject-runs and all CSP/MDM grouped-CV folds), including pipelines through the bring-your-own-code node and the CV orchestration; the remaining grouped-CV cells agree to floating-point precision (worst case 0.06 points, about one trial per fold). The stochastic deep models agreed within seed-to-seed training variability, estimated with multi-seed reruns on each side. The platform's execution engine therefore computes the same science as the reference stack across protocols, paradigms, and extensibility surfaces. The platform is available at https://studio.nimbusbci.com/, and the complete harness and per-subject results accompany this paper for independent verification.

0.15

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

cs.LG eess.SP ·2026-10-05 ·Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero
benchmark similarity 0.56
Abstract

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.

0.42

Target Selection with a Disappearing-Stimulus Mixed-Reality P300 Interface: Feasibility and Object-Distinguishable Versus Uniform Cues

cs.LG cs.HCeess.SP ·2026-11-10 ·Runqi Pan, Takuto Niinuma, Yunshan Huang, Masato Sugino, Kenta Shimba +1 more
similarity 0.56
Abstract · 5 pages, 2 figures, 1 table

Mixed-reality (MR) P300 interfaces can register selectable destinations, such as wheelchair goals, directly in the user's surroundings. When the cues disappear between flashes, however, the user must retain an intended target that is no longer visible. We tested whether such an interface supports target selection and whether giving each cue a stable colour-shape identity improves it compared with visually uniform spheres. Six healthy adults completed four trials in each cue condition of a 5x5 row/column task on a head-mounted MR display, with EEG from Fz, Cz, and Pz. Shrinkage linear discriminant analysis was evaluated with nested validation in which complete trials were held out from class balancing, hyperparameter selection, and fitting. Both conditions evoked a parietal target-related positivity. The decoded cell was correct in 18 of 48 held-out trials, against 1.9 expected by chance (binomial p < 1e-12), and in three participants individually. Cue format made no detectable difference: complete-target accuracy was 9/24 in both conditions (paired difference 0.0 percentage points, 95% CI [-37, 37]), and held-out AUC was 0.609 for spheres and 0.585 for object cues. Disappearing-stimulus MR P300 selection is therefore feasible under strict trial-level evaluation, but the benefit of object identity, if any, is too small to resolve in a pilot of this size.

0.25