Abstract

Mixed-reality (MR) P300 interfaces can register selectable destinations, such as wheelchair goals, directly in the user's surroundings. When the cues disappear between flashes, however, the user must retain an intended target that is no longer visible. We tested whether such an interface supports target selection and whether giving each cue a stable colour-shape identity improves it compared with visually uniform spheres. Six healthy adults completed four trials in each cue condition of a 5x5 row/column task on a head-mounted MR display, with EEG from Fz, Cz, and Pz. Shrinkage linear discriminant analysis was evaluated with nested validation in which complete trials were held out from class balancing, hyperparameter selection, and fitting. Both conditions evoked a parietal target-related positivity. The decoded cell was correct in 18 of 48 held-out trials, against 1.9 expected by chance (binomial p < 1e-12), and in three participants individually. Cue format made no detectable difference: complete-target accuracy was 9/24 in both conditions (paired difference 0.0 percentage points, 95% CI [-37, 37]), and held-out AUC was 0.609 for spheres and 0.585 for object cues. Disappearing-stimulus MR P300 selection is therefore feasible under strict trial-level evaluation, but the benefit of object identity, if any, is too small to resolve in a pilot of this size.

Comment
5 pages, 2 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Do Personal Adapters Carry Over Across Sessions? Separating Personal From Population Gains When Calibrating EEG Foundation Models for Motor Imagery

cs.LG eess.SPq-bio.NC ·2026-09-28 ·Xilin Tao, Kani Chen
similarity 0.58
Abstract · 8 pages main text + 9 pages supplementary material (appended). v2: substantially revised and retitled; adds cross-session experiments for CB…

Every new user of a motor imagery brain-computer interface must be calibrated, and users typically return on different days. A common approach with electroencephalography (EEG) foundation models fits a small personal adapter on a frozen backbone, but evaluations are usually confined to one session and rarely separate the user's own contribution from that of the population model. We quantified personal adapters with two paired contrasts, the net gain of a user's own adapter over the population model and its advantage over adapters fitted to other users, for three frozen foundation models (CBraMod, REVE and LaBraM). In 235 held-out subjects from three datasets, same-session calibration produced a positive net gain in all nine model and dataset combinations (means of 1.5 to 5.4 percentage points), and the gain remained positive when population training was quadrupled. In 54 two-session subjects, adapters fitted on the first day still improved on the population model on the second day by 1.31 points for REVE and 1.64 points for LaBraM (Holm-adjusted p<0.01), retaining 61% and 83% of the gain from same-day recalibration, whereas the gain for CBraMod was 0.04 points and indistinguishable from zero. Same-day recalibration gave the highest mean accuracy for all three models, and adding 5 to 20 second-day labels to the first-day adapter mostly fell short of it. Whether personal adapters carry over across sessions therefore depends on the model and must be tested per model, and personalization should be reported against both a population reference and exchanged parameters, including across sessions.

0.33

Streaming P300 Acquisition and Statistical Signal Validation Across Five EEG Platforms: A Hardware-Agnostic BrainFlow/LSL Pipeline

cs.HC ·2026-09-09 ·Isabella Guan, Rui Liu, Fusheng Wang
similarity 0.56
Abstract

P300 spellers offer people with severe motor impairment, such as ALS, an effective communication channel and remain one of the most established surgery-free alternatives to intracortical interfaces. Advanced language models have made spellers faster and more robust, yet the hardware beneath them is under-studied. We present a hardware-agnostic, real-time P300 acquisition pipeline built on BrainFlow and Lab Streaming Layer (LSL) that runs unchanged across consumer- and research-grade EEG headsets, with permutation tests of signal separability. Using a standard 6 x 6 row/column paradigm, we piloted five configurations: a custom dry system, a custom wet/gel system, Emotiv Flex, Emotiv EPOC X, and Muse 2. The custom systems and EPOC X showed weak or inconsistent signal separability, Muse 2 had the highest acquisition reliability despite limited centro-parietal coverage, and Flex showed the most promising signal. In 20 further Flex sessions varying subject, timing, and phrase length (131 target characters), a peak-amplitude permutation test and a cross-validated xDAWN decoder both detected a significant target response under two channel-exclusion policies, with decoder AUC reaching about 0.72 after 15 repetitions. Character accuracy depended heavily on evaluation methodology: in-sample majority voting reached 94.7%, whereas character-held-out accuracy was 31.3% with evidence accumulated across repetitions, about three times that of held-out majority voting. These analyses indicate that Flex captured a detectable, if still weak, P300 under the studied conditions, while broader participant-level validation and improved decoding remain necessary.

0.32

When More Is Not Better: Component Anti-Synergy in a P300 Speller

cs.LG ·2026-09-10 ·Lucas Yang, Rui Liu, Fusheng Wang
similarity 0.56
Abstract

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

0.18

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.55
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

Exploring Mixed-Reality for Enhancing Driver Warning Systems: A Preliminary Study on Attention-Shifting Methods and Hazard Perception

cs.HC ·2026-11-08 ·Shih-Yu Ma, Nolan Robert Brady, Xu Han, Neng-Hao Yu, Tom Yeh
published similarity 0.55
Abstract · 8 pages, 3 figures

Modern vehicles are equipped with advanced sensors and capabilities, yet engaging human drivers effectively in hazard perception remains a challenging research area. This paper investigates the potential of mixed reality (MR) to enhance driver warning systems. The study examines the impact of attention-shifting methods, including visual cues, audio cues, and a combination of both, on drivers' hazard perception. A preliminary study involving six participants was conducted, and the NASA-TLX analysis did not yield significant differences. However, through the use of functional near-infrared spectroscopy (fNIRS), we unveil distinct brain activation patterns associated with visual and sound cues. Further research with larger sample sizes and diverse driving scenarios is required to validate and expand upon these preliminary results.

0.64

METER: Matched-Event Calibration for Short-Event EEG Microstate Transition Analysis

cs.LG ·2026-11-01 ·Abdul Basit, Eklavya Tomar, Muhammad Shafique
similarity 0.54
Abstract · 36 pages. Supplementary material (16 pages) included as an ancillary file. Abdul Basit and Eklavya Tomar contributed equally

Short cognitive events contain unequal and often sparse transition evidence, so raw EEG microstate distances can reflect finite sampling rather than neural reconfiguration. We introduce METER (Matched-Event Transition Estimation against a Reference), a participant-relative framework that separates marginal occupancy from conditional next-state choice and evaluates each event against duration-conditioned events from a fixed participant-specific reference bank. METER-Jump integrates uncertainty in sparse target and reference transition tables, returning a randomized event rank for testing and a continuous standardized coordinate for association analysis. Using a reproducible three-state representation selected by spatial criteria, we evaluated METER with participant-fitted simulations, estimator ablations, map perturbations, and preprocessing sensitivities. Event-level false-positive rates were 0.044-0.056 across four heterogeneous null mechanisms. By contrast, global cutoffs learned under the participant-fitted null and transferred unchanged to other regimes produced false-positive rates from 0.004 under rare transitions to 0.234 under map perturbation; duration-conditioned ranks remained near 0.05. Detection probability was approximately 0.69 with fixed maps but fell to 0.22 after bootstrap-derived map-assignment perturbation. In 4,175 natural-reading events from 18 participants, no linguistic association survived multiplicity correction in the primary 30-ms analysis, although a 20-ms sensitivity changed one within-stream max-$T$ decision. METER therefore calibrates finite-event departures conditional on a defined microstate sequence, while map assignment, filtering, temporal smoothing, and reference construction remain separate sources of measurement uncertainty.

0.29

Virtual iEEG from Scalp EEG: Charting the Landscape of Source Imaging, Intracranial Inference and Reconstruction

cs.CV ·2026-08-27 ·Dongyi He, Xiangkai Wang, Hongjie Yan, Luping Song, Wai Ting Siok +1 more
similarity 0.53
Abstract

Intracranial electroencephalography (iEEG) provides temporally precise and spatially specific access to neural activity from focal and deep brain regions, but its invasiveness and restricted anatomical coverage limit routine use. These constraints have motivated scalp-to-intracranial inference, termed virtual iEEG when model outputs carry iEEG-defined event, feature, representation, or contact-level waveform semantics. This review presents a target-centred framework distinguishing event inference, feature translation, and waveform reconstruction, while separating predictability from observability, identifiability, fidelity, and utility. Evidence is evaluated according to cohort independence, anatomical and spectral coverage, train--test separation, and target-patient adaptation. Current studies support inference of selected intracranial events, low-frequency components, and task-related representations, but not unique recovery of arbitrary contact-level activity. Stronger validation requires appropriate controls, source-imaging baselines, uncertainty assessment, and incremental-utility testing. Future progress depends on independent paired datasets and prospective evidence that virtual iEEG adds value beyond scalp EEG and EEG source imaging.

0.22

Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task

cs.HC cs.LGeess.SP ·2026-10-05 ·Haochen Chai, Qixu Zhu, Siyao Li, Fangfang Jiang
benchmarkcode/data similarity 0.53
Abstract · 10 pages, 9 figures, 3 tables. Code and frozen data: https://github.com/rtb-1005/FairEDA

Artifact removal routinely precedes the classification of electrodermal activity (EDA), on the assumption that a cleaner signal supports a better decision. We tested this assumption in a virtual-reality (VR) balance-disturbance task. A residual gating network was trained on a benchmark with expert-corrected EDA, frozen, and applied to VR recordings, where raw and gated signals were classified by five published time-series methods under identical leave-one-participant-out evaluation. On the benchmark the gate detected artifacts well (median record AUROC 0.94) and reduced error inside artifact regions by 17.8%. In the VR task it did not improve classification. Changes in balanced accuracy ranged from -1.35 to +0.93 percentage points, no classifier improved and two lost accuracy, and all five were equivalent to raw input within +/- 3.32 points. The benefit was lost between waveform and decision. The correction that lowered waveform error also reduced skin conductance response detection in all 43 benchmark records. Processing left 92.8% of predictions unchanged, and the predictions it did change were corrected and corrupted at similar rates. The VR recordings also carried little contamination (an estimated 4.6% of samples), and even perfect localization of deliberately injected artifacts recovered only 3.3 points in the most sensitive classifier. A pooled association between artifact level and accuracy (11.3 points) disappeared within participants (0.1 points), showing how differences between people can make cleaning look useful. Preprocessing should be judged by the decision it supports, against an unprocessed arm.