CS Paper Radar

The U.S. Interconnection Queue System: Cascading Vulnerability Analysis and a Resilience Engineering Framework

Zahra Heidari

eess.SY ·submitted 2026-09-09 17:04 UTC · v1
positionunusual

Abstract

As of 2025, the U.S. interconnection queues, the grid-access gateway for new generation and storage, contain roughly 8,200 projects totaling 2,061 GW of capacity. Only 13% of capacity queued in 2000-2020 (19% by project count) has reached operation. We argue that the queue architecture is vulnerable to self-reinforcing project withdrawal cascades arising from restudy and cost reallocation, independent of study delays. Adapting failure contagion models from financial and interdependent infrastructure networks, we model the queue as a complex adaptive system and test it with a statistical analysis of withdrawal temporal clustering and co-withdrawal across seven ISO/RTOs and a stylized network contagion simulation of cost-sharing interdependencies with circuit-breaker interventions. Using LBNL project-level data through 2025, we find temporal clustering (dispersion indices 5.0-102.4; p < 0.001) and identify 39 monthly withdrawal bursts with the largest cluster-dated, reaching 67.4x the regional mean. Withdrawal timing is concentrated within technology categories in all seven regions (1,000-permutation test; z = 2.58-4.78, p <= 0.005). Co-withdrawal within cohorts is significant only in four regions (0.5-1.8 percentage points). The model yields net cascade amplification of 1.0-1.5x at low-to-moderate connectivity (average network degree k = 3-10). At k = 20 a phase-transition-like shift to systemic instability occurs, exceeding 8.7x amplification at a 10% shock (97.7% cascade size); a boundary condition of the stylized network that disappears under pro-rata redistribution. Capping per-neighbor cost reallocation reduces cascade magnitude by up to 20% relative to no intervention, with a 44% lower mean per-neighbor transfer. These findings characterize the interconnection queue as critical infrastructure with cascading vulnerability whose severity is conditional on cost allocation design.

Comment
23 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Resilience Enhancement of Distribution Grids Through a Three-Stage Framework for Scheduling Mobile Energy Storage Systems

eess.SY ·2026-09-24 ·Ali Abbasi, Kyri Baker
similarity 0.56
Abstract

As high-impact, low-probability disturbances such as extreme weather events increase in frequency, enhancing power grid resilience has become a critical priority. Mobile Energy Storage Systems (MESSs) have strong potential for helping with this purpose due to their high operational flexibility and fast deployability. They can be rapidly relocated to supply critical loads, support islanded operation, and adapt to changing conditions of the grid, making them a promising addition or alternative to conventional resilience-providing methods. This paper proposes a three-stage framework for scheduling MESS units. In the first stage (Normal Operation), charging/discharging scheduling of MESSs at buses is optimized for economic arbitrage. Upon receiving an early warning signal, the second stage (Proactive Positioning) shifts the focus to resilience. Here, the model determines the optimal staging points within the transportation network to minimize the expected time of arrival at critical loads, considering the probability distribution of line outages. The third stage (Dynamic Relocation) addresses the post-event restoration phase, in which MESSs are relocated in response to grid updates, such as subsequent line failures. Furthermore, a graph neural network-based solution approach is proposed to further enhance computational efficiency in determining the optimal placing of MESS units during the pre-allocation and relocation stages. The simulation results demonstrate that the proposed framework reduces expected energy not served and improves the restoration speed.

0.21

Cascading Contingency Analysis of Modern Power Systems Using a Stochastic Hybrid Systems Framework

eess.SY eess.SP ·2026-11-10 ·Masoud H. Nazari, Hamid Varmazyari
published similarity 0.56
Abstract · This paper was accepted at the 2026 North American Power Symposium (NAPS)

This paper presents a cascading contingency analysis and risk assessment framework that incorporates probabilistic mode transitions motivated by stochastic hybrid system (SHS) concepts together with power-flow-based stress evaluation. A two-stage modeling approach is adopted in which sensitivity-based analysis is first used to identify candidate cascading transitions, followed by DC power flow re-evaluation to accurately capture post-contingency stress redistribution, islanding behavior, and load shedding. A probabilistic propagation model is constructed using mode-dependent transition probabilities derived from line loading conditions. A Cascading Risk Index (CRI) is introduced to quantify the expected load shedding accumulated over cascade progression. Case studies on the IEEE 39-bus system demonstrate that the proposed framework captures diverse cascading routes under multiple initiating outages and identifies critical propagation patterns that are not revealed by N-1/N-2 screening. The results highlight the importance of SHS modeling in assessing cascading risk and providing a scalable framework for resilience evaluation in modern power systems.

0.34

A Community Impact-Centered Network Reduction Method for Power Systems Resilience Planning

eess.SY ·2026-10-27 ·Jiarui Gao, Abigail L. Beck, Rabab Haider
similarity 0.52
Abstract

Power systems resilience planning requires evaluating many hazard scenarios and investment portfolios, often requiring network reduction for computational tractability. The resulting aggregation, however, can obscure community impact data needed for equitable planning. We present a network reduction method that jointly preserves network physics and the spatial distribution of community data. We embed a household-level scarce resource score that characterizes outage impact within optimization-based Kron reductions with two formulations: a scarcity-weighted method that prioritizes vulnerable nodes, and a scarcity-constrained method that bounds data dissimilarity within aggregated clusters. Both are evaluated on a realistic distribution feeder of Galveston Island, Texas and benchmarked against multiple approaches. The scarcity-constrained method performs best, achieving 86% reduction with worst-case voltage errors below 0.01p.u. while preserving the spatial distribution of community data. By explicitly controlling data heterogeneity within and across clusters, the proposed method yields reduced networks that retain decision-relevant community information without sacrificing electrical accuracy.

0.29

SPARC: Substation-to-Peering Assessment of Resilience and Cascades

cs.NI ·2026-10-14 ·Tanya Shreedhar, Kevin Vermeulen, Amreesh Phokeer, Italo Cunha, Fernando Kuipers
similarity 0.52
Abstract · 40 pages, 17 figures, including appendices

Internet Exchange Points (IXPs) operate from colocation facilities that draw power from regional grids and store limited backup fuel. In April 2025, the Iberian blackout kept the Spanish grid down for 16 hours, beyond the 12 hours of fuel required by the industry standard, while traffic at major Iberian IXPs fell by up to 70%. Yet operators cannot tell which facilities a grid event cuts off, whether it outlasts their backup, or where traffic from a failed IXP goes. We present SPARC, which maps power-grid and Internet dependencies from substations to IXPs and their traffic. Using open data validated against transmission operators, SPARC links 552 facilities hosting 275 IXPs to the substations that likely feed them. We spread grid events over this map and measure failover through controlled BGP withdrawals on the PEERING testbed. Disabling the most-shared 16% of facility-feeding substations cuts power to half of all IXP presences (an IXP at one facility), under half of what randomized maps require. Losing the 5% most central substations cuts power to 0.1% of IXP presences directly but to 9-52% once the grid splits into disconnected islands. Traffic often fails over to nearby sites that share the failing grid: a cascade affecting four metropolitan areas sends up to 40% of one area's monitored addresses to another of the four. We introduce SPARC-Shield to select substations to harden or facilities whose backup to extend. Against an attacker disabling ten substations, hardening the ten selected by SPARC-Shield reduces offline IXP presence by 72%, compared with 52% for the best standard ranking.

0.30

U.S. Data Center Growth Through 2030: A Critical Review of Grid Adequacy and Transmission Expansion Planning

eess.SY ·2026-11-10 ·Babak Porkar, Mona Ghassemi
hot direction similarity 0.52
Abstract

The growth of large data centers raises questions about both supply adequacy and the suitability of load representations used in connection studies. This paper critically reviews the U.S. demand, generation, and transmission outlook through 2030 and examines the implications for transmission expansion planning (TEP). Comparison of public forecasts highlights distinctions among annual average demand, peak demand, and grid connection capacity. National generating-capacity totals cannot establish a dependable surplus because resource availability, regional adequacy, transmission constraints, and project timing determine supply capability. Recent grid events and published dynamic studies demonstrate that faults can trigger substantial data-center transfers to backup supply, followed by delayed or coordinated demand recovery. These behaviors require appropriate representation within the conventional planning framework, alongside assessment of the requested maximum grid import. The selected literature reveals limited integration of validated data-center dynamic models into the technical screening and economic comparison of expansion alternatives. The review identifies the need to establish whether fault response and recovery change feasible connection capacity, required reinforcement, or the preferred transmission investment.

0.28

Fast Reassessment of Prolonged Electricity Shortages under Shared Fuel Interruptions

eess.SY ·2026-10-19 ·Dogan Urgun
code/data similarity 0.51
Abstract · 11 pages, 4 figures, 5 tables. Submitted to IEEE Transactions on Reliability. Code and data: https://github.com/DoganUrgun/Fast_Reassessment…

When several generators share a fuel supply, one interruption can disable them together and cause electricity shortages lasting days. Such interruptions can be made less frequent, for example by weatherizing gas supply, or shorter, for example by on-site backup fuel. Yet traditional resource adequacy indices, expected unserved energy and loss-of-load hours, fail to distinguish such measures whenever they remove the same expected time without fuel, because for interruptions independent of system conditions these indices depend on the interruptions only through this time. Their difference is revealed by prolonged-shortage exposure, the expected annual hours in shortages of at least a given duration, whose exact chronological calculation must be repeated for every interruption scenario. To reduce this cost, a fast reassessment method with guaranteed accuracy is proposed. Network calculations are performed once and condensed into a restoration response, the additional prolonged-shortage hours caused by one interruption of each duration, from which any scenario is evaluated as a weighted sum without new simulation. An hour-by-hour error bound determines whether this evaluation is accurate enough, and exact dynamic programming is applied otherwise, so that every result lies within a requested tolerance of the exact value on the same Monte Carlo samples. On the Reliability Test System of the Grid Modernization Laboratory Consortium, most evaluations were accepted, fully accepted scenarios typically ran more than 200 times faster than exact calculation, and total computation time decreased in every workload. Measures against fuel interruptions can thus be screened quickly and accurately by their effect on prolonged shortages.

0.37

Capacity-Aware Redistribution Control for Mitigation of Cascading Failures in Networks

eess.SY math.OC ·2026-11-18 ·Ujjwal Pratap, Christian A. Hans
similarity 0.51
Abstract

This paper studies the control of irreversible cascading failures in networks with finite node capacities. Each node carries a nonnegative divisible quantity, referred to as load, and fails irreversibly when its load exceeds its capacity. The network dynamics are represented by topology-dependent row-stochastic matrices. When nodes fail, these matrices must be updated. However, directly deleting rows and columns corresponding to failed nodes can reduce the total load in the network. We therefore introduce a topology update that preserves unit row sums and quantifies any unserved load explicitly. We derive the resulting load-balance relation and a necessary and sufficient condition for lossless redistribution after simultaneous failures. Based on these results, we formulate a two-stage optimization problem: the first stage minimizes unserved load, and the second stage minimizes the highest capacity utilization among the surviving nodes. Simulations on grid and Barabasi-Albert networks show that, unlike the standard equal and residual-capacity redistribution approaches, the proposed method prevents secondary failures in all tested cases, with a tradeoff against served load on scale-free networks.

0.32

Composable, Knowledge-Driven Disservice Propagation for Complex Interdependent Services with a Flow-Allocation Module Validated Against Hydraulic Simulation

cs.CE ·2026-10-19 ·Cristian Curaba, Stefano Grimaz
publishedcode/data similarity 0.51
Abstract · Accepted at Complex Networks and Their Applications 2026 (COMPLEX NETWORKS 2026); supplementary material in ancillary files

Modeling cascading failure across interdependent critical infrastructure requires either a composable physical simulator per domain or a topological abstraction that discards quantity awareness. Simulators are costly, data-hungry, and require detailed calibration per domain; topological abstractions stay data-parsimonious while missing quantity-based behaviors that govern real dynamics. We present, instead, a knowledge-driven propagation architecture in which heterogeneous service dependencies are identified by categories: a general logical propagation resolves multi-dependency and redundancy structures purely from how nodes are categorized, while quantity-aware categories plug in dedicated mechanisms - here, a max-min fair-share flow module for water distribution. Both share one discrete functionality scale and a monotonic update algorithm guaranteeing convergence in finitely many rounds. We assess the flow module by comparing its results with those we get from preexisting pressure-driven simulation with WNTR (Water Network Tool for Resilience) on eight realistic networks across four failure families (clustered damage, capacity-targeted attack, source failure, tank loss). Under capacity-targeted attack and source failure a topological-reachability baseline misses 46% of the truly critical junctions, where the flow module misses 10% and 8% at an average critical-class precision of 0.73. Supplementary materials, code and results are available at: https://github.com/cascade-platform-org/CASCADE

0.46