CS Paper Radar

Cascading Contingency Analysis of Modern Power Systems Using a Stochastic Hybrid Systems Framework

Masoud H. Nazari, Hamid Varmazyari

eess.SY eess.SP ·submitted 2026-11-10 18:11 UTC · v1
published

Abstract

This paper presents a cascading contingency analysis and risk assessment framework that incorporates probabilistic mode transitions motivated by stochastic hybrid system (SHS) concepts together with power-flow-based stress evaluation. A two-stage modeling approach is adopted in which sensitivity-based analysis is first used to identify candidate cascading transitions, followed by DC power flow re-evaluation to accurately capture post-contingency stress redistribution, islanding behavior, and load shedding. A probabilistic propagation model is constructed using mode-dependent transition probabilities derived from line loading conditions. A Cascading Risk Index (CRI) is introduced to quantify the expected load shedding accumulated over cascade progression. Case studies on the IEEE 39-bus system demonstrate that the proposed framework captures diverse cascading routes under multiple initiating outages and identifies critical propagation patterns that are not revealed by N-1/N-2 screening. The results highlight the importance of SHS modeling in assessing cascading risk and providing a scalable framework for resilience evaluation in modern power systems.

Comment
This paper was accepted at the 2026 North American Power Symposium (NAPS)

Closest papers

Nearest neighbours by meaning across the whole index.

Centrality-based Structural-Electrical Contingency Screening and Transmission Reinforcement Prioritization

eess.SY ·2026-10-07 ·Abanish Tiwari, Chandan Chaudhary, Mekh Raj Joshi, Mohammed Ben-Idris, Joydeep Mitra
published similarity 0.70
Abstract · Accepted for IAS Annual Meeting 2026, Vancouver, Canada

Rapid contingency screening is essential for secure transmission system operation and planning. Although full AC contingency analysis provides accurate system assessment, it requires high computational effort for large contingency sets. Topology-based screening methods reduce this burden but may not accurately represent operating-point-dependent electrical stress. In addition, conventional single-contingency screening does not quantify interactions among simultaneous outages or provide a direct criterion for reinforcement prioritization. This paper presents a hybrid structural-electrical screening approach that combines a computationally efficient, dispatch-independent structural analysis based on reactance-weighted centrality measures with a flow-based severity assessment using line outage distribution factors. Two indices are evaluated using the flow-based severity: a synergy index to quantify super-additive interactions among simultaneous line outages and a tolerance index to rank reinforcement candidates based on their reduction in aggregate post-contingency severity. The correspondence between structural indicators and electrical severity is evaluated quantitatively. Tests on the IEEE 39-bus system identify 115 super-additive line pairs beyond a 5% threshold, with the most severe interaction exceeding seven times the linear combination of individual outage effects. The highest-ranked reinforcement reduces the mean post-contingency thermal severity by 7.5%. The structural rankings show limited correlation with flow-based severity, with a Spearman coefficient of approximately 0.2. The proposed approach provides an efficient pre-screening method to reduce contingency and reinforcement search spaces before detailed AC and economic evaluations.

0.30

Electrical Power Grid Reliability Assessment Exposed to Straight Line Winds

eess.SY ·2026-10-14 ·Satish Adhikari, Md Abul Hasnat
published similarity 0.67
Abstract · Accepted at the 2026 North American Power Symposium (NAPS)

Maintaining the resilience and reliability of electrical power grids under weather driven disturbances is a critical challenge for modern power system planning and operation. Among weather driven hazards, tornadoes and hurricanes are mostly considered for research purpose overlooking straight line winds despite its significant contribution to transmission line outages and cascading effects. Accurate modeling of these events is essential for operational decision making, and long term infrastructure planning and investment. This research explores the probabilistic risk assessment of transmission lines under straight line winds and their impacts on system level performance. The approach examines the probability of transmission towers failure, transmission lines outages, cascading effects, and identify critical transmission lines. The IEEE 118 bus system was utilized to validate the proposed approach and to demonstrate how wind induced component failures propagate throughout the network, affecting power grid reliability.

0.30

A New Analytical Method and Interpretation of Loss-of-Load Counts

eess.SY ·2026-11-12 ·Aidan Looney, Chanan Singh, Le Xie
similarity 0.59
Abstract · 5 pages, 3 figures, 1 table, submitted to IEEE PESGM

This paper establishes the relationship between loss-of-load expectation (LOLE) and loss-of-load frequency (LOLF). We show why LOLE generally does not measure distinct-event frequency, mean event duration, or shortage magnitude. We identify conditions under which peak-based LOLE admits a frequency interpretation as the expected count of deficient daily peaks per horizon and distinguish this quantity from LOLF. We also derive an analytical formulation for frequency-and-duration indices that combines a convolution-derived generation probability-and-frequency model with chronological load changes. Under stationary generation, it uses the prescribed load profile directly, without constructing a separate load model or discretizing load magnitudes. Studies using generation and load data from the 24-bus IEEE RTS reveal different event frequencies and mean event durations at identical peak-based LOLE, motivating their separate assessment. Numerical comparisons demonstrate the accuracy advantage of the proposed analytical calculation over the conventional analytical implementations, quantifying the LOLF errors incurred by load discretization.

0.18

Stochastic Distribution Network Reconfiguration under Load Uncertainty

eess.SY ·2026-10-08 ·Celso Cavellucci, Fábio Luiz Usberti
similarity 0.59
Abstract

This paper investigates distribution network reconfiguration under demand uncertainty using a two-stage stochastic formulation. The network topology is selected in the first stage, whereas the electrical variables are determined separately for each scenario. The deterministic equivalent is formulated as a MISOCP problem that accounts for power balances, losses, voltage constraints, and radiality. Experiments on 12 networks, ranging from 17 to 10,561 nodes, consider three demand scenarios. Reconfiguration reduced expected losses in all instances, with reductions ranging from 3.23% to 65.23% and averaging 31.76%, while also reducing the number of voltage violations in the ex post evaluation by approximately 55%. Eleven of the 12 problems were solved to optimality within the prescribed time limit. However, the additional benefit of stochastic modeling was negligible because of the homothetic structure of the scenarios considered, which preserves the spatial distribution of loads. The results show that spatially heterogeneous scenarios are important for the representation of uncertainty to meaningfully affect reconfiguration decisions.

0.27

Reliability-based Sizing of Energy Storage for Large Load Integration

eess.SY ·2026-11-18 ·Atri Bera, Chandan Chaudhary, Dilip Pandit, Cody J. Newlun, Tu A. Nguyen +2 more
published similarity 0.59
Abstract · 12 pages, 1 figure, published as part of the proceedings of the 2026 Grid of the Future Symposium organized by the CIGRE US National Committ…

The number of large loads connected to the bulk power system has been increasing rapidly worldwide. Emerging high-demand facilities, particularly AI data centers, are introducing new challenges for power system planners. In absence of appropriate planning mechanisms, the addition of high volumes of data center loads will lead to an increase in outages, thus degrading reliability of the system. Energy storage systems (ESS) offer a promising solution to mitigate the reliability impacts of these large loads, due to their flexibility and fast-ramping characteristics. However, ESS should be judiciously sized and sited to maximize the reliability benefits to the grid. This paper presents a framework for the optimal sizing and siting of ESS to minimize the adverse reliability impacts of large load additions. First, a stochastic semi-Markov model is developed to model the load of AI data centers and generate profiles for several such facilities. These profiles are then incorporated into a Markov-chain Monte Carlo simulation-based composite system reliability assessment framework. A detailed nodal network model is used to quantify the reliability impacts of adding data centers and to identify buses most affected by large loads. Resource adequacy metrics are used to evaluate the overall system reliability impacts. ESS are then strategically sized and sited based on this analysis to mitigate the negative impacts of large loads on overall system reliability. The proposed framework is demonstrated using the RTS-GMLC 72-bus test system. The results show how ESS can effectively enhance system reliability in the presence of rapidly growing large-load demand. This framework provides system planners, utilities, and regulators with a practical tool for maintaining reliable power system operation using energy storage as more large loads are integrated into the grid.

0.46

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.59
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34

A multi-stage probabilistic framework to estimate gas-fired generator performance during extreme winter weather

cs.LG stat.ML ·2026-10-03 ·Sajjad Uddin Mahmud, Anamika Dubey
similarity 0.59
Abstract

Extreme winter weather has repeatedly disrupted gas-fired power generation in the United States, yet the plant-level data needed to systematically quantify outage risk remain proprietary. Using publicly available weather and electricity demand data together with anonymized generator contingency records from the North American Electric Reliability Corporation (NERC), we develop a three-stage Bayesian probabilistic framework for estimating winter-driven generator performance. Applied to New York State (2013--2022), the framework sequentially estimates: the hourly probability of a generator contingency event, the expected net available capacity conditioned on an event occurring, and the event duration. Colder conditions and higher electricity demand are associated with higher failure probability, lower retained capacity, and longer event duration. Under the most severe observed stress conditions, estimated mean hourly event probability reaches 24\% , while expected mean net available capacity falls to 13\% of nameplate rating. Full outage events have a median duration of 12.7 hours, while partial derating event duration increases from 2.4 to 7.1 hours with capacity loss severity. The proposed framework establishes a transferable baseline that utilities with access to plant-level records can directly extend to obtain more precise reliability estimates for operational planning and resource adequacy assessment.

0.24

On the Concept of an Optimal Portfolio of Uncertain Flexible Loads

eess.SY ·2026-09-04 ·Julie Rousseau, Philipp Heer, Kristina Orehounig, Gabriela Hug
published similarity 0.58
Abstract · Accepted to the 2026 PowerUp conference

Flexible loads can enhance power system stability by providing reserves, but their limited energy capacity and uncertain availability distinguish them from conventional generators. To accommodate these characteristics, the Danish Transmission System Operator (TSO) recently introduced new reserve market rules that incorporate energy constraints and relax reliability requirements. In this context, the optimal reserve quantification becomes a joint chance-constrained reserve quantification problem, which is difficult to solve. In this paper, we derive two analytical reformulations of this problem: an exact one when a reserve direction dominates and an approximate one, otherwise. Furthermore, when flexible loads must collectively satisfy a reliability requirement, we introduce the concept of an optimal portfolio of flexible loads: adding loads with similar expected values but different stochastic behaviors to an existing portfolio may change the total portfolio's reserves. To support this idea, we theoretically study the marginal increase in reserves resulting from adding a load. Numerical results show that our analytical reformulations closely match the exact formulation, with a mean absolute error of 2.5%. Case studies further demonstrate the existence of optimal load groupings and our ability to predict the portfolio in which a load's marginal value is highest, leveraging our theoretical analysis.

0.43