CS Paper Radar

Electrical Power Grid Reliability Assessment Exposed to Straight Line Winds

Satish Adhikari, Md Abul Hasnat

eess.SY ·submitted 2026-10-14 18:32 UTC · v1
published

Abstract

Maintaining the resilience and reliability of electrical power grids under weather driven disturbances is a critical challenge for modern power system planning and operation. Among weather driven hazards, tornadoes and hurricanes are mostly considered for research purpose overlooking straight line winds despite its significant contribution to transmission line outages and cascading effects. Accurate modeling of these events is essential for operational decision making, and long term infrastructure planning and investment. This research explores the probabilistic risk assessment of transmission lines under straight line winds and their impacts on system level performance. The approach examines the probability of transmission towers failure, transmission lines outages, cascading effects, and identify critical transmission lines. The IEEE 118 bus system was utilized to validate the proposed approach and to demonstrate how wind induced component failures propagate throughout the network, affecting power grid reliability.

Comment
Accepted at the 2026 North American Power Symposium (NAPS)

Closest papers

Nearest neighbours by meaning across the whole index.

Cascading Contingency Analysis of Modern Power Systems Using a Stochastic Hybrid Systems Framework

eess.SY eess.SP ·2026-11-10 ·Masoud H. Nazari, Hamid Varmazyari
published similarity 0.67
Abstract · This paper was accepted at the 2026 North American Power Symposium (NAPS)

This paper presents a cascading contingency analysis and risk assessment framework that incorporates probabilistic mode transitions motivated by stochastic hybrid system (SHS) concepts together with power-flow-based stress evaluation. A two-stage modeling approach is adopted in which sensitivity-based analysis is first used to identify candidate cascading transitions, followed by DC power flow re-evaluation to accurately capture post-contingency stress redistribution, islanding behavior, and load shedding. A probabilistic propagation model is constructed using mode-dependent transition probabilities derived from line loading conditions. A Cascading Risk Index (CRI) is introduced to quantify the expected load shedding accumulated over cascade progression. Case studies on the IEEE 39-bus system demonstrate that the proposed framework captures diverse cascading routes under multiple initiating outages and identifies critical propagation patterns that are not revealed by N-1/N-2 screening. The results highlight the importance of SHS modeling in assessing cascading risk and providing a scalable framework for resilience evaluation in modern power systems.

0.34

Centrality-based Structural-Electrical Contingency Screening and Transmission Reinforcement Prioritization

eess.SY ·2026-10-07 ·Abanish Tiwari, Chandan Chaudhary, Mekh Raj Joshi, Mohammed Ben-Idris, Joydeep Mitra
published similarity 0.59
Abstract · Accepted for IAS Annual Meeting 2026, Vancouver, Canada

Rapid contingency screening is essential for secure transmission system operation and planning. Although full AC contingency analysis provides accurate system assessment, it requires high computational effort for large contingency sets. Topology-based screening methods reduce this burden but may not accurately represent operating-point-dependent electrical stress. In addition, conventional single-contingency screening does not quantify interactions among simultaneous outages or provide a direct criterion for reinforcement prioritization. This paper presents a hybrid structural-electrical screening approach that combines a computationally efficient, dispatch-independent structural analysis based on reactance-weighted centrality measures with a flow-based severity assessment using line outage distribution factors. Two indices are evaluated using the flow-based severity: a synergy index to quantify super-additive interactions among simultaneous line outages and a tolerance index to rank reinforcement candidates based on their reduction in aggregate post-contingency severity. The correspondence between structural indicators and electrical severity is evaluated quantitatively. Tests on the IEEE 39-bus system identify 115 super-additive line pairs beyond a 5% threshold, with the most severe interaction exceeding seven times the linear combination of individual outage effects. The highest-ranked reinforcement reduces the mean post-contingency thermal severity by 7.5%. The structural rankings show limited correlation with flow-based severity, with a Spearman coefficient of approximately 0.2. The proposed approach provides an efficient pre-screening method to reduce contingency and reinforcement search spaces before detailed AC and economic evaluations.

0.30

EPIGRIDS: Documentation and Validation of Seven Open Synthetic Transmission Grid Cases

eess.SY math.OC ·2026-11-13 ·Jonathan M. Snodgrass, Scott Greene, Thomas J. Overbye, Christopher L. DeMarco, Bernard C. Lesieutre
benchmark similarity 0.55
Abstract · 10 pages, 2 figures, 6 tables. Submitted to the IEEE Open Access Journal of Power and Energy. Cases: https://doi.org/10.5281/zenodo.23814538…

This paper documents and checks EPIGRIDS, seven open synthetic transmission grid cases from four independently built networks, made with an optimization-based construction method instead of the graph-statistics method behind most large public synthetic grids. The cases range from 250 to 78,484 buses, with geolocated substations, voltages up to 765 kV, and line parameters taken from conductor data. Each ships under an open license in three common power flow formats that agree at the solved operating point, and the six larger cases have a companion hourly, bus-level load series for one year. The Texas, Florida, and Michigan, Ohio, and Indiana cases are sub-networks of the Eastern case. Every case solves an alternating-current power flow from its stored operating point. With parallel circuits merged, the Eastern and Western cases are 9 and 16% denser than the real interconnections, while graph-statistics cases on the same footprints lie within 6% and meet more published realism criteria. A full single-outage contingency analysis completes on every case, and in an optimal power flow benchmark every case except the New England base case and one of its 12 operating points solves in polar form.

0.31

Congestion Price Uncertainty From Interconnection Queue by Monte Carlo Sampling

eess.SY ·2026-10-14 ·William A. Wheeler, Samuel Chevalier, Amritanshu Pandey
similarity 0.54
Abstract · 8 pages, 9 figures

The generation interconnection queue adds discrete uncertainty to power grid congestion price estimates on the project planning timescale. The conventional approach to this uncertainty is to make an informed guess of the single or few most likely configurations of generators that interconnect. In this paper, we show that Monte Carlo sampling is a more effective alternative. Given an estimate of the joint probability distribution of generator interconnections, a small number of samples yields good estimates of the congestion distribution. Crucially, this problem is not about rare events, but rather about the expected congestion over the worst times of the year, which makes congestion a common outcome over the distribution of interconnection events. We give empirical results on a 2000-bus network, averaging price outcomes from security-constrained DCOPF over eight different loading scenarios. For each line and contingency of the network, we estimate the full distribution as well as mean price and probability of exceeding a price threshold. Single-point estimates are unreliable and can be misleading about whether a line is likely to be congested. Combining the top k probability configurations yields improved estimates; however, sampling the same number from a distribution gives a more robust result of similar accuracy, as well as error estimates. Including correlation in the distribution model introduces small changes, showing that standard Bernoulli distributions suffice in most cases. The sampling approach is also applicable to large-load interconnection and should be of interest for planning both generation and large-load projects.

0.31

A multi-stage probabilistic framework to estimate gas-fired generator performance during extreme winter weather

cs.LG stat.ML ·2026-10-03 ·Sajjad Uddin Mahmud, Anamika Dubey
similarity 0.54
Abstract

Extreme winter weather has repeatedly disrupted gas-fired power generation in the United States, yet the plant-level data needed to systematically quantify outage risk remain proprietary. Using publicly available weather and electricity demand data together with anonymized generator contingency records from the North American Electric Reliability Corporation (NERC), we develop a three-stage Bayesian probabilistic framework for estimating winter-driven generator performance. Applied to New York State (2013--2022), the framework sequentially estimates: the hourly probability of a generator contingency event, the expected net available capacity conditioned on an event occurring, and the event duration. Colder conditions and higher electricity demand are associated with higher failure probability, lower retained capacity, and longer event duration. Under the most severe observed stress conditions, estimated mean hourly event probability reaches 24\% , while expected mean net available capacity falls to 13\% of nameplate rating. Full outage events have a median duration of 12.7 hours, while partial derating event duration increases from 2.4 to 7.1 hours with capacity loss severity. The proposed framework establishes a transferable baseline that utilities with access to plant-level records can directly extend to obtain more precise reliability estimates for operational planning and resource adequacy assessment.

0.24

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.54
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34

Resilience-Oriented Parametric Insurance Design for Power Systems Under Extreme Weather

eess.SY math.OC ·2026-08-15 ·Jing Huang, Yawen Ma, Jiale Guo, Chenjia Gu
similarity 0.53
Abstract

Extreme weather leaves power systems exposed to residual outage risk even after physical resilience investments. Parametric insurance can provide pre-agreed contingent liquidity, but its physical value depends on how trigger thresholds and payout levels are designed. This paper proposes a resilience oriented parametric insurance framework that couples a three tier wind-index contract with post-event network restoration. Insurance payout expands the budget available to activate emergency resources, so the contract changes the physical restoration feasible set rather than merely offsetting accounting losses. Trigger thresholds and payout levels are jointly designed to balance actuarial premium, expected post-event system cost, and the conditional value-at-risk (CVaR) of scenario energy not supplied (ENS). A response-library method precomputes the restoration mixed-integer linear program for each scenario-payout pair and then evaluates admissible contracts efficiently. On the IEEE RTS-24 with 80 extreme-wind scenarios, the optimized contract reduces expected EENS and CVaR0.90 of ENS by 21.1% and 21.4%, respectively, relative to no insurance, while requiring 48.8% less premium than a fixed parametric contract with comparable resilience. The results show that insurance design should target the nonlinear liquidity-to-resilience response rather than loss compensation alone.

0.04

Co-Optimization of Network Topology and Variable Impedance Devices under Dynamic Line Ratings Using Iterative McCormick Relaxation

eess.SY ·2026-10-27 ·Junseon Park, Hyeongon Park, Rahul K. gupta
benchmark similarity 0.52
Abstract

Grid Enhancing Technologies (GETs), such as Network Topology Optimization (NTO), Dynamic Line Rating (DLR), and Variable Impedance Devices (VIDs) are increasingly deployed in power transmission grids to address congestion and improve grid utilization. However, their growing adoption necessitates coordinated operation to fully exploit their benefits. This paper presents a unified co-optimization framework that integrates NTO, DLR, and VID to alleviate congestion and minimize operational costs. NTO is modeled using a node-breaker formulation to provide enhanced switching granularity, while DLR incorporates weather-dependent parameters, including wind speed and ambient temperature, to dynamically adjust transmission limits. The resulting formulation is a mixed-integer nonlinear program due to power flow constraints with bilinear VID terms, and discrete topology decisions. To improve tractability, we propose using a McCormick relaxation approach to linearize bilinear terms. Furthermore, we propose an iterative refinement of the McCormick relaxation scheme to enhance solution accuracy. The proposed framework is validated through detailed analyses on the IEEE 118-bus system, along with additional case studies on other benchmark systems to assess scalability. Results demonstrate that the proposed approach improves solution accuracy compared to standard McCormick relaxation, achieves solution quality close to the nonlinear formulation, and maintains computational efficiency.

0.29