Abstract

Rapid contingency screening is essential for secure transmission system operation and planning. Although full AC contingency analysis provides accurate system assessment, it requires high computational effort for large contingency sets. Topology-based screening methods reduce this burden but may not accurately represent operating-point-dependent electrical stress. In addition, conventional single-contingency screening does not quantify interactions among simultaneous outages or provide a direct criterion for reinforcement prioritization. This paper presents a hybrid structural-electrical screening approach that combines a computationally efficient, dispatch-independent structural analysis based on reactance-weighted centrality measures with a flow-based severity assessment using line outage distribution factors. Two indices are evaluated using the flow-based severity: a synergy index to quantify super-additive interactions among simultaneous line outages and a tolerance index to rank reinforcement candidates based on their reduction in aggregate post-contingency severity. The correspondence between structural indicators and electrical severity is evaluated quantitatively. Tests on the IEEE 39-bus system identify 115 super-additive line pairs beyond a 5% threshold, with the most severe interaction exceeding seven times the linear combination of individual outage effects. The highest-ranked reinforcement reduces the mean post-contingency thermal severity by 7.5%. The structural rankings show limited correlation with flow-based severity, with a Spearman coefficient of approximately 0.2. The proposed approach provides an efficient pre-screening method to reduce contingency and reinforcement search spaces before detailed AC and economic evaluations.

Comment
Accepted for IAS Annual Meeting 2026, Vancouver, Canada

Closest papers

Nearest neighbours by meaning across the whole index.

Cascading Contingency Analysis of Modern Power Systems Using a Stochastic Hybrid Systems Framework

eess.SY eess.SP ·2026-11-10 ·Masoud H. Nazari, Hamid Varmazyari
published similarity 0.70
Abstract · This paper was accepted at the 2026 North American Power Symposium (NAPS)

This paper presents a cascading contingency analysis and risk assessment framework that incorporates probabilistic mode transitions motivated by stochastic hybrid system (SHS) concepts together with power-flow-based stress evaluation. A two-stage modeling approach is adopted in which sensitivity-based analysis is first used to identify candidate cascading transitions, followed by DC power flow re-evaluation to accurately capture post-contingency stress redistribution, islanding behavior, and load shedding. A probabilistic propagation model is constructed using mode-dependent transition probabilities derived from line loading conditions. A Cascading Risk Index (CRI) is introduced to quantify the expected load shedding accumulated over cascade progression. Case studies on the IEEE 39-bus system demonstrate that the proposed framework captures diverse cascading routes under multiple initiating outages and identifies critical propagation patterns that are not revealed by N-1/N-2 screening. The results highlight the importance of SHS modeling in assessing cascading risk and providing a scalable framework for resilience evaluation in modern power systems.

0.34

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.61
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

Electrical Power Grid Reliability Assessment Exposed to Straight Line Winds

eess.SY ·2026-10-14 ·Satish Adhikari, Md Abul Hasnat
published similarity 0.59
Abstract · Accepted at the 2026 North American Power Symposium (NAPS)

Maintaining the resilience and reliability of electrical power grids under weather driven disturbances is a critical challenge for modern power system planning and operation. Among weather driven hazards, tornadoes and hurricanes are mostly considered for research purpose overlooking straight line winds despite its significant contribution to transmission line outages and cascading effects. Accurate modeling of these events is essential for operational decision making, and long term infrastructure planning and investment. This research explores the probabilistic risk assessment of transmission lines under straight line winds and their impacts on system level performance. The approach examines the probability of transmission towers failure, transmission lines outages, cascading effects, and identify critical transmission lines. The IEEE 118 bus system was utilized to validate the proposed approach and to demonstrate how wind induced component failures propagate throughout the network, affecting power grid reliability.

0.30

Data-Optimized Contingency Screening: A Machine Learning Approach to Power System Security

cs.AI cs.LG ·2026-09-03 ·Joshua Salako, Folajimi Osikomaiya, Olakorede Olamiju
published similarity 0.59
Abstract · Accepted for presentation at the 3rd EIE International Conference on Computing, Networking, Robotics and Telecommunication (EIECon), 2025. T…

Ensuring the security of the power system is essential for stability and reliability, especially in the event of disruption. Effective classification of contingency in power systems enables proactive decision-making and mitigates large-scale breakdowns and failures. This study explores the use of machine learning algorithms to classify security levels of contingencies in power systems into safe, moderate or severe classes. For this approach, Newton-Raphson load flow method extracts system data from contingency scenarios, using Overall Performance Index (OPI) as safety measure. For data pre-processing, Synthetic Minority Over-Sampling Technique (SMOTE) and Principal Component Analysis (PCA) is used to address class imbalance and reduce dimensionality, respectively. K-Nearest Neighbours (KNN), Random Forest (RF) and Support Vector Machines (SVM) is trained and evaluated on datasets generated through N-k contingency scenarios for k equal 1, 2, and 3 on IEEE-14 and IEEE-30 bus systems using four hybrid pre-processing configurations: normalized, SMOTE-balanced, PCA-transformed, and a combined SMOTE PCA-transformed. Performance is assessed by precision, recall and F1 score, with priority given to the severe contingency classes. The RF achieved the highest F1 scores of 0.97 in IEEE-30 and 0.86 in IEEE-14, SVM benefits significantly from PCA and improves the accuracy of the classification, while KNN is best suited for SMOTE and PCA conversion. The findings show that PCA contributes more than SMOTE to the overall performance of the model. However, SMOTE improves recall but can introduce false positives and is therefore a compromise of accuracy. This study highlights machine learning as a scalable and powerful alternative to traditional contingency analysis, which improves the assessment of security in real time.

0.25

Causal Discovery for Resiliency-Prioritized Transmission Expansion Planning in Power Systems with Grid-Forming Inverter-Based Resources

eess.SY ·2026-11-15 ·Roy McCann, Mustafa Mhawesh, Sandra Canas Rivera
benchmark similarity 0.57
Abstract

Transmission planners at regional transmission organizations (RTOs), independent system operators (ISOs), and NERC-registered entities have limited analytical resources for exploring expansion options that improve resiliency for withstanding and recovering from fault conditions in electric power systems that are dominated by grid-forming (GFM) and grid-following (GFL) inverter-based resources (IBRs). Conventional existing TPL-001 contingency analysis will assess if a performance benchmark is violated. However, it will not identify which dynamic states and inputs caused the violation, nor how much a protective action will avoid propagation into a cascading outage. This paper proposes an analytical method that combines time-series causal discovery using the Peter and Clark Momentary Conditional Independence (PCMCI) algorithm with right/left eigenvector participation-factor analysis of validated small-signal state-space models. Synthetic data are generated from linearized models derived from substation phasor measurement unit (PMU) data. This includes node-breaker topologies under alternative transmission switching configurations. GFM and GFL inverter controls including phase-locked loops (PLLs) and fault ride-through logic. A planning index referred to as the Resiliency Causal Contribution Index (RCCI) is defined that weights PCMCI-derived causal effects on a TPL benchmark quantity by modal participation. The planning procedure iterates contingency categories, measures margins to RTO/ISO benchmarks for transient voltage recovery, oscillatory damping, inverter ride-through, and TPL-008-1 extreme temperature. The process infers automatic protective actions and repeats until a cascade is ruled out or confirmed. A simplified case study illustrates the entire process for considering the options in transmission expansion planning.

0.33

Co-Optimization of Network Topology and Variable Impedance Devices under Dynamic Line Ratings Using Iterative McCormick Relaxation

eess.SY ·2026-10-27 ·Junseon Park, Hyeongon Park, Rahul K. gupta
benchmark similarity 0.55
Abstract

Grid Enhancing Technologies (GETs), such as Network Topology Optimization (NTO), Dynamic Line Rating (DLR), and Variable Impedance Devices (VIDs) are increasingly deployed in power transmission grids to address congestion and improve grid utilization. However, their growing adoption necessitates coordinated operation to fully exploit their benefits. This paper presents a unified co-optimization framework that integrates NTO, DLR, and VID to alleviate congestion and minimize operational costs. NTO is modeled using a node-breaker formulation to provide enhanced switching granularity, while DLR incorporates weather-dependent parameters, including wind speed and ambient temperature, to dynamically adjust transmission limits. The resulting formulation is a mixed-integer nonlinear program due to power flow constraints with bilinear VID terms, and discrete topology decisions. To improve tractability, we propose using a McCormick relaxation approach to linearize bilinear terms. Furthermore, we propose an iterative refinement of the McCormick relaxation scheme to enhance solution accuracy. The proposed framework is validated through detailed analyses on the IEEE 118-bus system, along with additional case studies on other benchmark systems to assess scalability. Results demonstrate that the proposed approach improves solution accuracy compared to standard McCormick relaxation, achieves solution quality close to the nonlinear formulation, and maintains computational efficiency.

0.29

Assessing Data Center Hosting Capacity Considering Electromagnetic Transient Dynamics

eess.SY ·2026-11-11 ·Fan Jiang, Xingpeng Li
hot direction similarity 0.55
Abstract

Hosting capacity is commonly assessed with steady-state optimization, which leaves the dynamic response of the data center and the grid at the resulting operating point untested. This paper assesses candidate data center capacities by coupling a unit commitment (UC) model with electromagnetic transient (EMT) simulation. During the capacity search, the UC model determines the economic dispatch for each tested data center capacity, and the resulting operating points are tested for settling with the generators committed online by the UC model and after a selected synchronous generator outage. Three nested capacities are obtained: the optimization-based steady-state capacity, the dynamic pre-outage capacity, and the post-outage dynamic capacity, each bounded by the previous one. On a test system with a detailed data center model, both dynamic capacities fall well below the optimization capacity, and the ranking of connection locations changes with the assessment stage and with the outage. In the most severe outage case at each candidate bus, the capacity is about 30% below the steady-state capacity. Thus, the dynamic response of the data center and the grid should be part of the hosting capacity assessment, and the comparison of connection locations should be made on the post-outage dynamic capacity.

0.26

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.55
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34