CS Paper Radar

An Automated Thickness Evaluation Procedure Using an Integrated Structured Light 3D Camera in a Robotic Bioprinting Framework

Ehsan Zobeidi, Omid Rezayof, Farshid Alambeigi

cs.RO ·submitted 2026-09-10 21:02 UTC · v1
published

Abstract

Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with complex geometries. Leveraging the point cloud and RGB images of a structured light 3D camera, our proposed method performs an image-based segmentation for delineating the BPCs from the RGB images, accompanied by novel geometry-based thickness measurement algorithms performed on the point cloud scans. These algorithms combine the segmentation mask with the robot's forward kinematics data and a 3D point cloud scan to precisely measure the aforementioned metrics for complex-shaped BPCs. The proposed method was evaluated in simulation and experimental studies. In simulation studies, the algorithms were used to measure the thickness of some virtually created BPCs with known thickness. The comparison between the measured and true thicknesses demonstrates the high accuracy of the proposed method, achieving mean absolute errors between 0.025 mm and 0.057 mm in simulation at a spatial resolution of 0.1 mm x 0.1 mm per pixel. Furthermore, we successfully deployed the algorithms on our robotic bioprinting setup utilizing a structure light 3D camera, where complex patterns were printed and the developed methods utilized to accurately measure the thickness of printed BPCs.

Comment
This paper has been accepted for publication at the 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Adaptive Depth-Map-Guided Bundle Adjustment for Correspondence-Free Multi-View Point Cloud Registration

cs.RO ·2026-09-01 ·Yiran Zhou, Yingyu Wang, Shoudong Huang, Liang Zhao
code/datahot direction similarity 0.60
Abstract · 10 pages, 5 figures

Robotic processing of irregular steel scrap requires dense 3-D measurement to replace manual visual assessment in hazardous cutting workcells. The reconstructed map is used to estimate piece dimensions, boundary geometry, feasible preheating and cutting regions, and collision-aware torch paths. The reconstruction errors therefore propagate directly to downstream measurement and planning. Existing multi-view registration methods commonly rely on feature extraction and data association to establish correspondences between views. In workcells with smooth metallic surfaces, repeated structures, occlusions, and partial overlaps, however, wrong correspondences may be established, leading to inaccurate pose estimation and distorted reconstruction. This paper presents an adaptive layered depth-map-guided bundle adjustment framework for correspondence-free multi-view point cloud registration. The scene is represented by a global 2.5-D grid, where each cell can adaptively maintain multiple depth hypotheses. Raw depth observations are directly projected into the global map to form depth constraints without explicit feature correspondences. At grid cells where multiple surfaces produce conflicting depths, a softmax-based layer assignment links each observation to compatible depth hypotheses. The resulting nonlinear least-squares formulation jointly refines sensor poses and the layered depth map, with correspondences implicitly induced by the depth-map representation and projection model. Experiments on self-collected industrial datasets show that the proposed method achieves consistently competitive reconstruction accuracy while maintaining robustness and low computational cost in challenging industrial scenarios. We release the open-source code implementation at: https://github.com/YiranZhou-Robotics/ADM-BA.git

0.42

A Physics-Based Closed-Loop Robotic Bioprinting Framework Towards Volumetric Muscle Loss Treatment

cs.RO ·2026-09-10 ·Omid Rezayof, Jerin T. Andrews, Ehsan Zobeidi, Ali Ghasemkhani, Meenakshi Kamaraj +3 more
published similarity 0.59
Abstract · This paper has been accepted for publication and presentation in 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (I…

Robotic bioprinting and Direct Ink Writing (DIW) are being explored towards the treatment of Volumetric Muscle Loss (VML). While previous studies have shown the importance of proper parameter selection on the print outcome, existing approaches often rely on time- and material-intensive design of experiments methods, or require large, well-curated datasets for training machine learning models. In this paper, we propose a physics-based closed-loop robotic bioprinting system capable of near real-time parameter adaptation. The system integrates a 3D point cloud camera and fully autonomous vision-based algorithms to provide quantitative evaluation of printed constructs. This evaluation is fed into a controller that adjusts printing parameters to achieve a desired bead thickness. To assess the framework's performance, four experimental configurations were tested, each repeated three times. In these tests, printing began from an arbitrary initial parameter value, and the controller was tasked with adjusting the parameters to reach the desired thickness. The system converged in all trials, achieving a tracking error below 0.5 mm within an average of 5.2 seconds from the start of printing. The low standard deviation of the converged pressure over different tests (0.04 bar on average) demonstrates robustness and repeatability. Additional experiments were conducted with the controller turned off, enabling direct comparison with open-loop DIW bioprinting, further confirming the effectiveness of the proposed closed-loop framework in achieving the desired bead geometry.

0.42

3D Point Cloud from Close-Range Photogrammetry for Defect Characterisation of Rubberised Concrete

cs.CV ·2026-08-21 ·Jiacheng Liu, Mohammed Alnahhal, Ailar Hajimohammadi, Sara Gonizzi Barsanti, Jinling Wang +1 more
published similarity 0.56
Abstract · 8 pages, 10 figures. Published in the International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, XXV ISP…

While three-dimensional (3D) point clouds are widely used in civil engineering, mainstream LiDAR systems such as Terrestrial Laser Scanning (TLS) are physically constrained to laboratory environments. Since their laser spot size typically exceeds the width of microcracks, the beam physically bridges over voids, rendering TLS unsuitable for fine-scale defect analysis. Alternatively, close-range photogrammetry utilising Structure-from-Motion (SfM) and Multi-View Stereo (MVS) algorithms offers a solution for testing highly tortuous materials, and its utility at fine-scale remains underexplored. This study adapts photogrammetric workflows specifically for rubberised concrete (RuC), a sustainable composite exhibiting high ductility and complex fracture morphologies. High-resolution image sets were captured using a Canon DSLR and an iPhone 16 to generate dense 3D models. Comparisons revealed that the DSLR-based reconstruction achieved sub-millimetre resolution, demonstrating superior performance for fine-scale surface monitoring. An RGB-guided crack extraction method was developed to enhance the identification of surface defects and isolate potential crack areas from the background. The extracted crack regions were visually distinguishable and provided a well-structured geometrical representation of defect morphology. Furthermore, a Pre and Post-Test deformation analysis was conducted to quantify surface displacement across testing stages. The results confirm that this close-range photogrammetry workflow is a flexible, high-resolution alternative to LiDAR for surface inspection and deformation monitoring of specimens in laboratory settings. Ultimately, this approach establishes a robust geometric baseline for future automated 3D feature characterisation and material performance evaluation.

0.62

Validation of Smartphone-Based Photogrammetric 3D Body Scanning for Automated Anthropometric Measurements Compared with a Commercial Depth-Sensor-Based Body Scanner

cs.CV ·2026-08-13 ·Ruting Cheng, Boyuan Feng, Chuhui Qiu, Joaquin A. Calderon, Qing Pan +2 more
published similarity 0.55
Abstract · 16 pages, 5 figures, 4 tables

3D body scanning has become an important tool in healthcare applications because of its rapid and non-invasive nature. While smartphone-based photogrammetric reconstruction provide a low-cost and accessible alternative to commercial 3D body scanners, their performance for whole-body scanning remains insufficiently validated. Thus, we designed this study to comprehensively validate the photogrammetric 3D scanning application by evaluating automatically extracted whole-body measurements and longitudinal body-shape monitoring. We evaluated a representative application, PolyCam, against the commercial depth-sensor-based Fit3D ProScanner using 144 pregnant participants scanned longitudinally throughout pregnancy. We designed an automatic circumference extraction pipeline to get measurements at four anatomical landmarks from paired 3D scans. A linear mixed-effects model was used to evaluate scanner effects and longitudinal body-shape changes. Measurement consistency was assessed using repeated PolyCam scans and tape measurements on a rigid mannequin. PolyCam demonstrated strong agreement with Fit3D, with average biases below 16 mm, intraclass correlation coefficients above 0.8, and Pearson correlation coefficients above 0.9 across all landmarks. Both systems captured comparable longitudinal body-shape changes. Mannequin experiments showed mean biases below 3.5 mm and no significant differences from tape measurements. These findings support smartphone photogrammetry as a potential accessible alternative to commercial body scanners and applicable for longitudinal 3D body-shape assessment.

0.28

Active sensing to characterize the heterogeneity of plant stress

cs.RO cs.AI ·2026-08-27 ·Ayman Laaroussi, Peter Hanappe, David Colliaux
similarity 0.55
Abstract · UR2026

While most phenotyping platforms rely primarily on image-based measurements, advanced plant characterization requires the integration of active physiological sensing modali- ties such as chlorophyll fluorescence. We present an autonomous robotic platform designed to perform targeted fluorescence measurements on plant leaves. The system combines 3D plant reconstruction, geometric analysis, and motion planning to localize suitable measurement points and generate collision-free trajectories for a robotic manipulator. A dense 3D model of the plant is reconstructed from multi-view data and used to extract candidate leaf surfaces based on orientation, accessibility, and sensing constraints. These targets are then integrated into a task-level planning framework that guides the end-effector to precise contact or near-contact configurations required for point-based fluorescence acquisition. The platform enables automated, repeatable, and spatially resolved physiological measurements that go beyond passive imaging. By tightly coupling perception, geometric reasoning, and manipulation, the proposed system provides a robotics-driven approach to high-resolution plant phenotyping and opens new directions for autonomous agricultural inspection and plant-aware manipulation.

0.29

Object-Centered Reconstruction for Vision-Based 3D Force Estimation

cs.RO ·2026-09-20 ·Zhonghao Zhang, Mingyeung Wu, Hao Yang, Ayberk Acar, Alan Kuntz +1 more
similarity 0.54
Abstract

Excessive force may damage tissue and increase the risk of anastomotic leakage in robotic colorectal surgery. Although the da Vinci 5 provides force sensing, this capability is unavailable on earlier da Vinci systems and many other surgical robotic platforms. In this work, we present a vision-based pipeline for estimating 3D interaction forces from soft-tissue deformation in stereo endoscopic video. We dynamically reconstruct the tissue point cloud in an object-centered coordinate frame, track tissue points with geometric constraints, and predict the 3D force vector with a neural network. We progressively evaluate the pipeline on rubber-glove phantoms, ex vivo porcine colons, and in vivo colorectal surgical video sequences. Under varying tissue orientations and positions within the endoscopic view, as well as different camera viewpoints, the proposed method achieves average root mean square error (RMSEs) of 0.77 N and 1.30 N on the phantom and porcine colon, respectively. Compared with the camera-frame representation, the object-centered representation reduces average RMSE by 51.3% and 56.7%, while geometry-constrained tracking reduces RMSE by 19.8% and 25.3% compared with CoTracker. We further qualitatively demonstrate the feasibility of vision-based force estimation on an in vivo colorectal surgical sequence, as a step toward clinical translation of vision-based, sensorless force estimation.

0.18

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.54
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

VisTa3D: A Dataset and Benchmark for Thin Object Reconstruction from Vision, Tactile, and 3D Point Clouds

cs.CV ·2026-08-21 ·Shania Guo, Yeongsik Seo, Andrew Fu, Mei Hao, Iris Xia +5 more
top venuebenchmarkcode/data similarity 0.54
Abstract

State-of-the-art 3D reconstruction models, whether from visual, range, or both, tend to underperform on thin objects. This is partially due to the small amount of space such objects occupy in RGB images and in 3D point clouds. To test the extent of their errors, we collected the first thin object dataset comprising of synchronized RGB images, depth maps, and tactile response maps, where each frame is associated with inertial measurements, camera pose and calibration, and groundtruth depth and segmentation maps obtained from laser scanning of thin objects. We hypothesize that tactile data can aid in the reconstruction of thin objects as their response maps provide local shape and deformation information. Our dataset, termed VisTa3D, comprises of 387 scenes covering 70 thin objects over 17 environments. We benchmarked current 3D reconstruction models on VisTa3D and found that, indeed, they exhibit low fidelity on thin objects. To test if tactile data can help, we introduce the first visual-range-tactile 3D reconstruction model as a baseline. Code and data: https://huggingface.co/datasets/shaniaguo/VisTa3D.

0.66