CS Paper Radar

A Physics-Based Closed-Loop Robotic Bioprinting Framework Towards Volumetric Muscle Loss Treatment

Omid Rezayof, Jerin T. Andrews, Ehsan Zobeidi, Ali Ghasemkhani, Meenakshi Kamaraj, Maryam Tilton, Johnson V. John, Farshid Alambeigi

cs.RO ·submitted 2026-09-10 19:44 UTC · v1
published

Abstract

Robotic bioprinting and Direct Ink Writing (DIW) are being explored towards the treatment of Volumetric Muscle Loss (VML). While previous studies have shown the importance of proper parameter selection on the print outcome, existing approaches often rely on time- and material-intensive design of experiments methods, or require large, well-curated datasets for training machine learning models. In this paper, we propose a physics-based closed-loop robotic bioprinting system capable of near real-time parameter adaptation. The system integrates a 3D point cloud camera and fully autonomous vision-based algorithms to provide quantitative evaluation of printed constructs. This evaluation is fed into a controller that adjusts printing parameters to achieve a desired bead thickness. To assess the framework's performance, four experimental configurations were tested, each repeated three times. In these tests, printing began from an arbitrary initial parameter value, and the controller was tasked with adjusting the parameters to reach the desired thickness. The system converged in all trials, achieving a tracking error below 0.5 mm within an average of 5.2 seconds from the start of printing. The low standard deviation of the converged pressure over different tests (0.04 bar on average) demonstrates robustness and repeatability. Additional experiments were conducted with the controller turned off, enabling direct comparison with open-loop DIW bioprinting, further confirming the effectiveness of the proposed closed-loop framework in achieving the desired bead geometry.

Comment
This paper has been accepted for publication and presentation in 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Controlling Continuum Robot Shape in Enclosed Space with Embedded Sensing using IMU and Actuator Feedback

cs.RO ·2026-10-28 ·Jiahe Wang, Sultan Haidar Ali, Eric Weissman, Jiefeng Sun
similarity 0.62
Abstract · 8 pages, 7 figures

Controlling continuum robots' shape to operate in confined, enclosed environments is challenging, since it cannot rely on external observation. Existing embedded shape sensing methods, although they can provide shape reconstruction, are insufficient to enable real-time shape control due to limitations in reconstruction accuracy, computational speed, and compatibility with shape-state representation. In this work, we present an embedded shape-sensing framework that uses readily available IMU and actuator feedback to reconstruct the continuum-robot shape with a neural network, providing accurate shape feedback at $400~\mathrm{Hz}$ for physical closed-loop control. We systematically investigate four key reconstruction design choices: shape-state representation, network architecture, training objective, and sensing inputs, through more than $5{,}000$ trained models on one- and three-segment continuum robots. The selected framework achieves global shape errors of $0.9\%L$ and $1.7\%L$ (of the robot length) for the one- and three-segment systems, respectively. In closed-loop control, one-segment tip tracking achieves a $6.1\%L$ error and three-segment shape control achieves a $2.3\%L$ global shape error, whereas IMU--PCC reconstruction using the same uncompensated measurements fails. Enclosed-space experiments further demonstrate operation without external observation. These results provide a practical framework for translating readily available embedded sensing into high-rate feedback for continuum robot closed-loop control.

0.34

An Automated Thickness Evaluation Procedure Using an Integrated Structured Light 3D Camera in a Robotic Bioprinting Framework

cs.RO ·2026-09-10 ·Ehsan Zobeidi, Omid Rezayof, Farshid Alambeigi
published similarity 0.59
Abstract · This paper has been accepted for publication at the 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with complex geometries. Leveraging the point cloud and RGB images of a structured light 3D camera, our proposed method performs an image-based segmentation for delineating the BPCs from the RGB images, accompanied by novel geometry-based thickness measurement algorithms performed on the point cloud scans. These algorithms combine the segmentation mask with the robot's forward kinematics data and a 3D point cloud scan to precisely measure the aforementioned metrics for complex-shaped BPCs. The proposed method was evaluated in simulation and experimental studies. In simulation studies, the algorithms were used to measure the thickness of some virtually created BPCs with known thickness. The comparison between the measured and true thicknesses demonstrates the high accuracy of the proposed method, achieving mean absolute errors between 0.025 mm and 0.057 mm in simulation at a spatial resolution of 0.1 mm x 0.1 mm per pixel. Furthermore, we successfully deployed the algorithms on our robotic bioprinting setup utilizing a structure light 3D camera, where complex patterns were printed and the developed methods utilized to accurately measure the thickness of printed BPCs.

0.58

Towards end-to-end co-design for one-shot printable task-specific soft robots

cs.RO ·2026-11-02 ·James Wood, André Farinha, Will Browne, Josh Pinskier, Krishna Manaswi Digumarti
similarity 0.58
Abstract

Soft robot co-design methods can jointly optimise morphology and control, but the resulting designs are often difficult to manufacture, while manufacturable approaches typically restrict actuator placement or require manual assembly. We present a simulation-based co-design framework that jointly optimises material distribution, pneumatic actuator placement and orientation, and control, while producing designs that can be fabricated monolithically using fused deposition modelling. The framework uses a differentiable 2D plane-stress Material Point Method simulator, incorporating an experimentally validated material model and an empirically derived surrogate model of a 3D-printed inflatable actuator. We demonstrate gradient-based optimisation soft robotic arms for prescribed tip trajectories. Optimised designs are transferred directly from simulation to one-shot monolithic FDM fabrication, with integrated actuators and no post-assembly. Physical experiments demonstrate that the resulting arms reproduce the behaviour predicted in simulation. This framework provides a path from task-level objectives to physically realisable soft robots while retaining substantial freedom over both morphology and actuation.

0.14

Optimization-Based Path Planning for Industrial Manipulators: Experimental Validation in Additive Manufacturing

cs.RO math.OC ·2026-11-10 ·Shiva Ganesh Murali, Valentin Bhend, Deepak Ingole, Gabriele Fadini, Alisa Rupenyan
similarity 0.58
Abstract · Submitted for the review in ECC 2027

Robotic additive manufacturing requires joint paths that reconcile robot feasibility with process-specific geometry. We develop an offline optimization-based path planner that combines joint-path regularity and self-collision penalties with process costs and constraints, so that a new process enters through its own reference, residuals, and tolerances. Full-path and boundary-coupled chunked optimization handle references of different lengths. Iterative Weight Tuning (IWT) determines the cost weights from the gaps between Key Performance Indicators (KPIs) and their targets. In carbon-fiber winding and robotic 3D printing, the planned paths meet the geometric tolerances and all KPI targets, and both paths are executed on a UR10e, without extrusion for printing, with joint-level tracking recorded during execution.

0.22

Robotic Optical Coherence Tomography-Guided Geometric Modeling of Soft Tissue: 3D Representations for Data-Driven Closed-Loop Shape Control

cs.RO ·2026-10-23 ·Chaoyu Zhang, Guangshen Ma, Mark Draelos
similarity 0.58
Abstract · 30 pages, 18 figures

In medical robotics, data-driven soft-tissue shape control requires deforming tissue toward desired morphologies through sequential physical interactions. This challenge is particularly important in microscale manipulation, where localized deformation is difficult to observe, represent, and control, while physics-based models can be computationally expensive and difficult to adapt to realistic environments. Optical coherence tomography (OCT) provides high-resolution volumetric perception of tissue deformation, but target-conditioned control requires effective representations of both observed and desired tissue states. In this work, we introduce an OCT-guided data-driven framework for tissue shape control, learned from user-guided demonstrations and executed with closed-loop OCT feedback. We study full-volume, tissue-masked sparse-volume, and voxelized point-cloud representations, with or without residual conditioning, using deterministic (Explicit) and generative diffusion (Diffusion) policies. Across 12 configurations and 576 phantom rollouts on 3-DoF depth and 6-DoF directional tasks, OCT-derived 3D representations support both Explicit and Diffusion policies, with performance depending on representation and residual conditioning. Residual conditioning reduces directional Shape RMSE from 0.748 to 0.555 mm for full-volume Diffusion, while voxelized point-cloud Explicit with residuals achieves 0.534 mm for depth and 0.443 mm for directional control, with comparable accuracy at intermediate unseen targets and consistent performance across deployments. We further evaluate the framework in 60 ex vivo porcine rollouts, extending to biological tissue with final geometric errors comparable to human demonstrations. These results establish volumetric OCT as current and goal representations for learned closed-loop tissue shape control across deterministic and generative action models.

0.07

Print&Fold: Printing and Folding Shape-accurate 3D Models

cs.HC ·2026-08-13 ·Archit Kumar, Zachary Grimm, Mingsheng Xu, Shlok Rathi, Martin Nisser
top venue similarity 0.57
Abstract · Proceedings of ACM UIST 2026

This paper introduces Print&Fold, a tool to allow FDM 3D printing of complex models with less time and material while preserving shape accuracy. Key to this work is a folding algorithm that planarizes foldable faces internal to the 3D model. While folding techniques typically discretize a target model's surface, thereby fabricating low fidelity counterparts, our method preserves the surface features in the physical print. Our design tool allows users to unfold 3D models to be FDM-printed flat before manually folding these into their target shapes. We showcase a variety of applications and evaluate the material and time savings across a range of 3D models.

0.34

AI-guided robotic in situ fabrication of curvature- and tissue-adaptive wireless bioelectronics

cs.RO ·2026-11-13 ·Hiroyuki Tetsuka, Jiaju Ma, Naomi Kumano, Minoru Hirano
similarity 0.57
Abstract

Personalized bioelectronic devices for wound therapy require not only conformal fabrication on complex body surfaces but also functional adaptation of their electrical characteristics to individual wound geometries. Here, we present an AI-guided robotic in situ printing platform for fabricating wireless wound electrotherapy devices directly on transparent wound dressings. The system integrates a 3D vision camera, a six-degree-of-freedom robotic arm, direct-ink-writing, and geometry-aware RF design optimization. AI-based wound segmentation is used to determine wound dimensions and local surface curvature, while the reconstructed three-dimensional geometry is incorporated into the electromagnetic design of the receiving coil and interdigitated electrodes. In contrast to conventional approaches that use surface geometry only for trajectory generation, the proposed method accounts for both anatomical curvature and tissue dielectric loading to compensate for geometry-induced shifts in resonant behavior. A printable silver ink was characterized in terms of rheology, dimensional reproducibility, electrical resistance, and electromechanical stability, and was used to fabricate multilayer wireless devices directly on curved polyurethane dressings. Wireless power transfer, impedance characteristics, and electric-field delivery were evaluated experimentally and numerically. Finally, robotic in situ fabrication was demonstrated on an anthropomorphic tissue-equivalent forearm phantom, where the measured dielectric properties of the phantom were incorporated into the RF optimization, enabling resonant operation near the target frequency of 25 MHz. This work establishes a perception-to-design-to-fabrication framework for geometry-adaptive wireless bioelectronics and provides a technological foundation for future physical-AI-enabled manufacturing of personalized on-body electrotherapy devices.

0.23

SaddleSense: Saddle-Shaped Modules for 3D Shape Sensing with Single-Axis Off-the-Shelf Bend Sensors

cs.RO ·2026-10-31 ·Dong Heon Han, Runze Zuo, Chankyo Kim, Saima Jamal, Daniel Bruder
similarity 0.56
Abstract

Accurate posture feedback is essential for precise control of continuum robots. Off-the-shelf bend sensors measure curvature about only one axis; without a suitable mounting arrangement, they can restrict robot motion and provide incomplete posture information. SaddleSense introduces a 3D-printed thermoplastic polyurethane (TPU) saddle-shaped lattice that holds one commercial bend sensor along each curved edge. Because each sensor flexes within its own channel rather than spanning the segment axially, the lattice converts multi-axis body deformation into sensor curvature without tying segment length to sensor length. Each four-sensor module accommodates two-axis bending, contraction, and extension while quantifying all three deformation modes across its four readings. A hybrid calibration maps the sensor readings to piecewise constant curvature (PCC) parameters using a learned model paired with a physics-based fallback for out-of-distribution inputs. We demonstrate a six-module prototype with 24 off-the-shelf bend sensors on a 430~mm continuum body. Using only each module's four local readings, the physics-based model alone achieves a tip position root mean square error (RMSE) of 29.9~mm (7.0\% of body length). The data-driven model reduces the tip RMSE to 13.2~mm (3.1\%) on held-out samples of motions similar to the training set and 15.8~mm (3.7\%) on separately recorded trials. Reducing each module from four sensors to one nearly triples the tip error.

0.32