CS Paper Radar

AI-guided robotic in situ fabrication of curvature- and tissue-adaptive wireless bioelectronics

Hiroyuki Tetsuka, Jiaju Ma, Naomi Kumano, Minoru Hirano

cs.RO ·submitted 2026-11-13 01:14 UTC · v1

Abstract

Personalized bioelectronic devices for wound therapy require not only conformal fabrication on complex body surfaces but also functional adaptation of their electrical characteristics to individual wound geometries. Here, we present an AI-guided robotic in situ printing platform for fabricating wireless wound electrotherapy devices directly on transparent wound dressings. The system integrates a 3D vision camera, a six-degree-of-freedom robotic arm, direct-ink-writing, and geometry-aware RF design optimization. AI-based wound segmentation is used to determine wound dimensions and local surface curvature, while the reconstructed three-dimensional geometry is incorporated into the electromagnetic design of the receiving coil and interdigitated electrodes. In contrast to conventional approaches that use surface geometry only for trajectory generation, the proposed method accounts for both anatomical curvature and tissue dielectric loading to compensate for geometry-induced shifts in resonant behavior. A printable silver ink was characterized in terms of rheology, dimensional reproducibility, electrical resistance, and electromechanical stability, and was used to fabricate multilayer wireless devices directly on curved polyurethane dressings. Wireless power transfer, impedance characteristics, and electric-field delivery were evaluated experimentally and numerically. Finally, robotic in situ fabrication was demonstrated on an anthropomorphic tissue-equivalent forearm phantom, where the measured dielectric properties of the phantom were incorporated into the RF optimization, enabling resonant operation near the target frequency of 25 MHz. This work establishes a perception-to-design-to-fabrication framework for geometry-adaptive wireless bioelectronics and provides a technological foundation for future physical-AI-enabled manufacturing of personalized on-body electrotherapy devices.

Closest papers

Nearest neighbours by meaning across the whole index.

Electrospun Fields: 3D Nano-Fiber Material Computation as Design Method

cs.GR cond-mat.softcs.RO ·2026-08-24 ·Wai Lok Wan, Ayah Mahmoud, Sergio Mutis, Avantika Velho, Annie Xing +1 more
publishedcode/dataunusual similarity 0.59
Abstract · 15 pages, 10 figures. Published in Proceedings of the ACM on Computer Graphics and Interactive Techniques (SIGGRAPH 2026). Open-source hardw…

We present a robotic electrospinning platform and design method for depositing nanofiber membranes onto non-planar, three-dimensional conductive geometries. Conventional electrospinning relies on fixed emitters and planar grounded collectors, which restricts deposition to flat substrates: on concave geometries, field shielding prevents fibers from reaching recessed regions, and material bridges across elevated features instead. We address this with a custom end-effector integrated with a six-axis UR20 arm. The tool carries a localized stepper-driven syringe pump that maintains consistent polymer flow independent of orientation, and routes high-voltage DC (up to 25 kV) directly to a robot-mounted needle, turning the arm into a mobile emitter with full kinematic control over position, orientation, working distance, and traversal velocity. Toolpaths that continuously reorient the emitter along surface normals give access to concave topologies unreachable by fixed-axis systems. We characterize the resulting deposition behavior in two parts. A catalog of four bio-compatible polymer systems (PEO, PVA, keratin-PEO, silk-PEO) establishes the operating envelope, reporting deposition speed, jet stability, fiber size, alignment, and durability for each. A taxonomy of 3D-printed conductive scaffolds spanning geometric primitives, hybrid compositions, and square, triangular, and hexagonal lattices links collector geometry to fiber alignment, density, and cross-void bridging. We also demonstrate programmable grounding, in which selectively energized pins in an array steer deposition without changing physical geometry. Assembly instructions and toolpath-generation code are released as an open-source repository.

0.49

A Physics-Based Closed-Loop Robotic Bioprinting Framework Towards Volumetric Muscle Loss Treatment

cs.RO ·2026-09-10 ·Omid Rezayof, Jerin T. Andrews, Ehsan Zobeidi, Ali Ghasemkhani, Meenakshi Kamaraj +3 more
published similarity 0.57
Abstract · This paper has been accepted for publication and presentation in 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (I…

Robotic bioprinting and Direct Ink Writing (DIW) are being explored towards the treatment of Volumetric Muscle Loss (VML). While previous studies have shown the importance of proper parameter selection on the print outcome, existing approaches often rely on time- and material-intensive design of experiments methods, or require large, well-curated datasets for training machine learning models. In this paper, we propose a physics-based closed-loop robotic bioprinting system capable of near real-time parameter adaptation. The system integrates a 3D point cloud camera and fully autonomous vision-based algorithms to provide quantitative evaluation of printed constructs. This evaluation is fed into a controller that adjusts printing parameters to achieve a desired bead thickness. To assess the framework's performance, four experimental configurations were tested, each repeated three times. In these tests, printing began from an arbitrary initial parameter value, and the controller was tasked with adjusting the parameters to reach the desired thickness. The system converged in all trials, achieving a tracking error below 0.5 mm within an average of 5.2 seconds from the start of printing. The low standard deviation of the converged pressure over different tests (0.04 bar on average) demonstrates robustness and repeatability. Additional experiments were conducted with the controller turned off, enabling direct comparison with open-loop DIW bioprinting, further confirming the effectiveness of the proposed closed-loop framework in achieving the desired bead geometry.

0.42

CROPS: Cosserat-Rod-Based Co-Design of Soft Slender Programmable Material Systems for Biomedical Applications

cs.CE cs.RO ·2026-10-16 ·Aaditya Chandrasekhar, Dex Doksoo Lee, Hyunwoo Kwon, Shicheng Li, Wei Chen
similarity 0.55
Abstract · Submitted to Finite Elements in Analysis and Design

Slender structures made of stimuli-responsive materials represent an emerging class of programmable material systems, with applications in soft robotics, minimally invasive surgery, wearable electronics, and deployable structures. In biomedical applications, the on-demand design of slender structures, encompassing both their material layout and actuation, is essential to harnessing their large deformation and multiphysics actuation to meet patient-specific design requirements. However, owing to geometric and material nonlinearities, their structure-actuation-response relationship is highly nonintuitive and computationally demanding. This often makes trial-and-error and conventional design approaches challenging for addressing patient-specific needs. To this end, we present a Cosserat-rod-based design optimization framework for the autonomous design of programmable slender structures. Leveraging the Cosserat rod representation, the end-to-end differentiable framework is demonstrated on two case studies: (i) design of swellable stents that morph to the shape of carotid vessels; (ii) co-design of the remnant magnetization and the applied field of magnetically-active catheters to reduce the force exerted on the patient-specific vessel wall during insertion. Both self-contact and external contact with surrounding structures are accounted for. We consider two actuation mechanism, namely the swelling of gel-elastomer composites and the magnetic actuation of hard-magnetic composites. The proposed framework presents an autonomous design platform of soft slender material systems that support large deformations and multiphysics actuation toward personalized biomedical design.

0.25

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

cs.RO ·2026-10-07 ·Charles DeLorey, Michael Brockdorff, Adam Metcalf, Benjamin Calmé, Pietro Valdastri +1 more
similarity 0.54
Abstract · 9 pages, 12 figures

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

0.17

Proximity3D: Shape from Capacitive Proximity on Sensing Manifold

cs.CV cs.CGcs.GRcs.RO ·2026-08-31 ·Hao Chen, Chenming Wu, Chun Ping Lam, Xiangjia Chen, Guoxin Fang +4 more
published similarity 0.54
Abstract

Most shape reconstruction methods assume measurements defined over planar sensing domains, such as RGB images or depth maps. In this paper, we use a curved capacitive textile as a shape sensor, treating its surface as a non-planar sensing manifold. Each scan is represented as a capacitive proximity field on this manifold, induced by the interaction between the curved electrode layout and nearby object geometry. We introduce a multi-view feedforward reconstruction model that aggregates these fields across known sensor views and recovers the observed object shape. Simulated and physical experiments demonstrate robust reconstruction from capacitive proximity signals acquired on curved sensing surfaces, pointing toward a new route to robotic near-field geometric awareness via embodied sensing.

0.34

Selectively Actuated Fiberbots for High-precision Minimally Invasive Surgery

cs.RO ·2026-10-08 ·Jinshi Zhao, Libaihe Tian, Alex Ranne, Qindong Zheng, Yue Li +7 more
similarity 0.54
Abstract · 7 pages, 7 figures

Long, slender instruments are essential for minimally invasive surgery (MIS), but achieving precise distal manipulation becomes increasingly difficult when actuation extends along the entire instrument. Here, we present an electrothermally actuated fiber-based robot designed for MIS procedures, in which Joule heating is concentrated in the distal active segment. The fiber is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 $μ$m. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allow independent motion. A phantom demonstration combining the robotic fiber with a da Vinci instrument conceptually demonstrated its compatibility with existing endoscopic systems for clinical applications. Our robotic fiber enables precise distal motion and holds the potential to improve clinical outcomes by enhancing precision in MIS procedures.

0.33

Toward 3D Printable Non-Planar Electroadhesive Structures for Active Anchoring

cs.RO ·2026-09-16 ·Mostafa A. Atalla, Carol R. Derla, Pep Canyelles Pericàs, Gijs Krijnen
publishedbenchmark similarity 0.54
Abstract · Accepted for publication in the proceedings of the IEEE SENSORS 2026

This paper investigates multi-material 3D printing as a method to fabricate non-planar structures with 3D-printed electrode patterns for electroadhesion. We printed flat electroadhesion pads as a planar benchmark and cylindrical pads as a non-planar demonstration, with conductive interdigitated electrodes 3D printed as part of the structure. Normal-force measurements showed voltage-controlled modulation in both geometries. At 3 kV, the flat pads generated approximately 0.11-0.13 N, while the cylindrical pads reached approximately 0.16 N at 5 N preload. These results demonstrate a step toward printed parts with built-in, electrically controlled adhesion and friction, beyond conventional planar electroadhesion pads.

0.37

Ex vivo breach detection using electrical conductivity during robotic pedicle drilling in the spine

cs.RO ·2026-10-01 ·Jorge Andrés Pérez Velásquez, François Teyssere, Thibault Chandanson, Quentin Grimal, Brahim Tamadazte
similarity 0.53
Abstract

Purpose: Pedicle screw placement is technically demanding in scoliosis treatment. High precision is required due to limited visibility, anatomical variability, and the risk of complications. Although robotic systems assist CT-based planning and execution, they still rely on ionizing intraoperative imaging and complex registration. This study proposes robotic pedicle drilling with real-time preventive breach detection using electrical bioimpedance sensing. Methods: We developed a robotic approach combined with a pedicle-drilling tool equipped with a proprioceptive electrical bioimpedance sensor developed by SpineGuard. A real-time detection algorithm was designed to analyze the electrical bioimpedance signal during drilling and identify abrupt changes in conductivity associated with potential breaches towards the spinal canal. The method operates without external devices or sensors. Results: The ex vivo experiments showed that the proposed method prevented breaches in 100 of the 51 drilling cases. These findings demonstrate the system's ability to detect potentially hazardous events during drilling and to stop the procedure before. The ex vivo experiments demonstrated that the proposed method prevented breaches in all 51 drilling cases. Conclusions: This work demonstrates the feasibility of robotic pedicle drilling with electrical bioimpedance sensing for real-time breach prevention. Using only the tool signal, the method eliminates the need for external sensing systems and supports safer pedicle screw placement.

0.25