CS Paper Radar

Ex vivo breach detection using electrical conductivity during robotic pedicle drilling in the spine

Jorge Andrés Pérez Velásquez, François Teyssere, Thibault Chandanson, Quentin Grimal, Brahim Tamadazte

cs.RO ·submitted 2026-10-01 08:42 UTC · v1

Abstract

Purpose: Pedicle screw placement is technically demanding in scoliosis treatment. High precision is required due to limited visibility, anatomical variability, and the risk of complications. Although robotic systems assist CT-based planning and execution, they still rely on ionizing intraoperative imaging and complex registration. This study proposes robotic pedicle drilling with real-time preventive breach detection using electrical bioimpedance sensing. Methods: We developed a robotic approach combined with a pedicle-drilling tool equipped with a proprioceptive electrical bioimpedance sensor developed by SpineGuard. A real-time detection algorithm was designed to analyze the electrical bioimpedance signal during drilling and identify abrupt changes in conductivity associated with potential breaches towards the spinal canal. The method operates without external devices or sensors. Results: The ex vivo experiments showed that the proposed method prevented breaches in 100 of the 51 drilling cases. These findings demonstrate the system's ability to detect potentially hazardous events during drilling and to stop the procedure before. The ex vivo experiments demonstrated that the proposed method prevented breaches in all 51 drilling cases. Conclusions: This work demonstrates the feasibility of robotic pedicle drilling with electrical bioimpedance sensing for real-time breach prevention. Using only the tool signal, the method eliminates the need for external sensing systems and supports safer pedicle screw placement.

Closest papers

Nearest neighbours by meaning across the whole index.

Novel Ex-vivo Calf Brain Model with Integrated Sub-Skull Force Sensors to Access Simulated Neurosurgical Procedures

cs.RO eess.SY ·2026-09-13 ·Hamad Binhammad, Matheus Ballestero, Mohammed Babgi, Seana Shaka, Nima Hemati +7 more
similarity 0.53
Abstract

Surgical tissue manipulation demands precision; however, tool-tissue manipulation force magnitudes under realistic conditions are rarely quantified. To address this gap, we proposed and validated a portable ex-vivo force-sensing platform that measures tool-tissue interaction forces across the skull-brain interface during simulated neurosurgery. The system involves fresh calf brain tissue, used as a biological surrogate for brain parenchyma, placed in a 3D-printed human skull model equipped with a 6 degree-of-freedom force/torque sensor and a real-time data acquisition system. Five validation protocols assessed the accuracy and dynamic fidelity of the platform against ground-truth measurement, static accuracy and linearity using calibrated weights (0.5-50 g), minimum detectable force, spatial consistency across different anatomical regions, effect of surgical draping, and long-duration stability. Across protocols, measured forces showed excellent agreement with reference loads (correlation R = 0.9997), with RMSE < 0.005 N and mean relative error under 2%. The platform reliably detected low-magnitude forces down to 1 g (9.8 mN), while surgical drapes introduced no meaningful signal distortion and prolonged recordings exhibited minimal drift. Overall, the proposed framework provides objective, high-fidelity force quantification for skill training and performance assessment using fresh calf brain tissue and may serve as a foundation for force-based evaluation across other surgical procedures. Future work will integrate clinically used surgical instruments to increase procedural realism and will progress toward clinical trials to evaluate usability, educational impact, and translational relevance in practice-adjacent settings.

0.25

AI-guided robotic in situ fabrication of curvature- and tissue-adaptive wireless bioelectronics

cs.RO ·2026-11-13 ·Hiroyuki Tetsuka, Jiaju Ma, Naomi Kumano, Minoru Hirano
similarity 0.53
Abstract

Personalized bioelectronic devices for wound therapy require not only conformal fabrication on complex body surfaces but also functional adaptation of their electrical characteristics to individual wound geometries. Here, we present an AI-guided robotic in situ printing platform for fabricating wireless wound electrotherapy devices directly on transparent wound dressings. The system integrates a 3D vision camera, a six-degree-of-freedom robotic arm, direct-ink-writing, and geometry-aware RF design optimization. AI-based wound segmentation is used to determine wound dimensions and local surface curvature, while the reconstructed three-dimensional geometry is incorporated into the electromagnetic design of the receiving coil and interdigitated electrodes. In contrast to conventional approaches that use surface geometry only for trajectory generation, the proposed method accounts for both anatomical curvature and tissue dielectric loading to compensate for geometry-induced shifts in resonant behavior. A printable silver ink was characterized in terms of rheology, dimensional reproducibility, electrical resistance, and electromechanical stability, and was used to fabricate multilayer wireless devices directly on curved polyurethane dressings. Wireless power transfer, impedance characteristics, and electric-field delivery were evaluated experimentally and numerically. Finally, robotic in situ fabrication was demonstrated on an anthropomorphic tissue-equivalent forearm phantom, where the measured dielectric properties of the phantom were incorporated into the RF optimization, enabling resonant operation near the target frequency of 25 MHz. This work establishes a perception-to-design-to-fabrication framework for geometry-adaptive wireless bioelectronics and provides a technological foundation for future physical-AI-enabled manufacturing of personalized on-body electrotherapy devices.

0.23

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

cs.RO ·2026-10-07 ·Charles DeLorey, Michael Brockdorff, Adam Metcalf, Benjamin Calmé, Pietro Valdastri +1 more
similarity 0.50
Abstract · 9 pages, 12 figures

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

0.17

An Open-Source da Vinci X/Xi Instrument Module for Laparoscopic Surgery Research

cs.RO ·2026-11-16 ·Douglas McDonough, Justin Liao, Jiawei Ge, Antony Goldenberg, Yvonne Zhang +4 more
code/data similarity 0.47
Abstract · Submitted to the 2027 International Symposium on Medical Robotics (ISMR). † Equal contribution. ‡ Equal supervision

Studying electrosurgical tasks on a research robot requires control of both instrument motion and energy activation, along with a record of when each action occurs. This paper presents an open-source module for da Vinci X/Xi instruments on a UR5/UR5e robotic arm. Five motors transmit torque through timing belts to spring-loaded drive discs. An electrosurgical interposer accepts software commands, gives the surgeon's foot pedals priority, and records the source of each activation request. In bench testing, the interposer recorded all 12 activation and deactivation events from six pedal presses. Ex vivo demonstrations included monopolar and bipolar coagulation of splenic tissue and monopolar cutting during gallbladder dissection. Optical tracking of the Fenestrated Bipolar Forceps showed that calibration brought pitch and yaw gains from 0.904 and 1.14 to 1.00 and 1.02, respectively. The module enables researchers to record instrument motion, video, and the timing and source of electrosurgical commands during laparoscopic tasks.

0.32

A Durable Vision-Based Tactile Fingertip for Robotic Manipulation

cs.RO ·2026-08-25 ·F. Richard Cottrell, Megha H. Tippur, Edward H. Adelson
similarity 0.47
Abstract · 22 pages, 20 figures

Currently available commercial vision-based tactile sensors provide rich contact information but remain vulnerable to abrasion and repeated concentrated loading, limiting their use in demanding robotic applications. This work presents a durable tactile fingertip comprising a soft silicone gel with a nonpigmented, textured, thin thermoplastic-polyurethane protective film and a replaceable sensing cartridge. Durability was evaluated using two accelerated laboratory procedures: a rotating-drum sanding test and a repetitive probe test applying 39.2 N (4.0 kgf) at 45 cycles per minute. Under the defined sanding conditions, the developed sensor reached the protective-film rupture endpoint after approximately 2-3 hours. During repetitive probe testing, all nine developed sensors remained functionally usable when testing was discontinued: seven after 5 days, one after 6 days, and one after 8 days. Commercial GelSight Mini and DIGIT specimens exhibited initial surface-film rupture after approximately 24-30 seconds of sanding and 25-35 minutes of repetitive loading. Damage to the developed sensor progressed gradually and produced little interference with tactile imaging at the test endpoints. These observations establish durability improvements of more than two orders of magnitude under the defined accelerated conditions. Combining increased durability, gradual degradation, and rapid cartridge replacement offers a practical approach to maintainable vision-based tactile sensing for demanding robotic applications.

0.27

Topology optimisation and simulated state reconstruction for self-sensing piezoresistive grippers

cs.CE ·2026-09-13 ·Connor N Mallon, Zachary J Wegert, Anthony P Roberts, Joshua Pinskier, Harry Bowman +1 more
similarity 0.47
Abstract

We consider the computational design of a self-sensing robotic gripper that has the potential to reduce reliance on traditional external sensors. We computationally investigate the potential of a novel sensing method that exploits the coupled electromechanical properties of piezoresistive materials to enable mechanical perception using sparse electrical measurements. In this theoretical proof-of-concept, we show that under the idealised assumptions of linear constitutive relationships and quasi-static gripper operation, it is possible to reconstruct simple contact shapes and gripper displacement fields using a small number of simulated electrical measurements, suggesting the potential of the proposed sensing technique. We use topology optimisation to promote the quality of displacement state recovery by adding an electrical performance objective to the mechanical compliance requirement of the gripper. Using the proposed reconstruction technique, we showcase the improved reconstruction ability of an electrically optimised gripper design through an increased robustness to noisy synthetic measurements compared to a gripper designed with only a mechanical objective in the topology optimisation problem. In the future, detailed inclusion of non-linear effects and experimental realisation of this theoretical proof-of-concept may help remove the constraints of traditional sensors for robotic handling, potentially facilitating sensing in settings where current sensing systems are impractical.

0.29

Anticipatory Textile MMG-Strain Sensing for Confirm-Then-Assist Soft Knee Exosuits

cs.RO ·2026-10-11 ·Zheng Ma, Xiao Jin, Zhenhua Yu
similarity 0.47
Abstract · 8 pages, 9 figures, 4 tables

Soft wearable robots must commit to assistance around movement onset, when the available signals are ambiguous. Surface electromyography (sEMG) detects neuromuscular drive early but degrades under sweat and electrode shift, and kinematic sensors respond only once the limb moves. This letter presents a knitted textile interface that co-samples a three-channel mechanomyography (MMG) array and an anterior strain sensor on a single synchronous 500 Hz clock. Across five participants, MMG activation preceded strain-detected knee motion during sit-to-stand by per-channel medians of 322-344 ms. Sampled on the same clock, the sign of the strain slope resolved movement direction on 649 of 650 completed transitions with no training or per-participant calibration, raising four-class balanced accuracy from 90.3% to 95.6%. The fused signals drove a two-stage confirm-then-assist policy for a soft pneumatic knee. Across 240 trials in four participants, the onboard controller entered the assist state on 78 of 80 sit-to-stand trials and on none of the 80 isometric co-contractions. It also entered the assist state on 27 of 80 stand-to-sit trials and left it at the hold timeout, motivating an antagonistic flexor gauge to resolve this direction at onset. Co-sampling muscle acoustics with textile strain on one clock lets the inflation command be issued around movement onset.

0.37

Feature extraction for LSTM-based finger-joint angle estimation from sEMG

cs.LG ·2026-11-02 ·Gerda de Jager, Marelie H Davel, Ian Thomson
similarity 0.46
Abstract · 20 pages, 8 figures

Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control.

0.28