TRACE: Two-Stage Detector-Response Estimation With Angular Cosine Expansion for Ring Artifact Correction in Photon-Counting CT

Jigang Duan, Heran Wang, Ligen Shi, Zheng Sun, Ping Yang, Xing Zhao

cs.CV ·submitted 2026-09-14 16:31 UTC · v1

Abstract

Detector response nonuniformity introduces systematic projection errors and ring artifacts in photon-counting detector computed tomography (PCD-CT). In measured PCD-CT data, residual stripe amplitudes vary slowly with projection angle, which fixed-bias models cannot adequately capture. We propose TRACE, a two-stage unsupervised sinogram decomposition method for estimating and correcting these response-related errors. TRACE represents stripes as a fixed bias plus low-order discrete cosine transform (DCT) components, using a small number of coefficients to describe angular variations at each detector element. A learnable analysis--synthesis architecture represents the ideal projections, while two-stage optimization separates them from fixed and then dynamic stripes. An angular-gradient soft orthogonality constraint suppresses correlated variations within the shared DCT gradient subspace, reducing the leakage of object structures into the artifact estimate. All parameters are optimized directly on the measured sinogram without paired training data. Experiments on measured QRM mouse phantom and porcine trotter data show that TRACE suppresses ring artifacts and improves image uniformity while preserving edge sharpness, soft-tissue texture, and trabecular detail.

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Driven Independent Pair Generation for Iterative Self-Supervised Low-Dose CT Denoising

cs.CV ·2026-09-01 ·Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
similarity 0.57
Abstract · 10 pages, 11 figures, 3 tables. Includes a 1-page appendix. Submitted to IEEE Transactions on Circuits and Systems for Video Technology

Low-dose computed tomography (LDCT) measurements contain mixed Poisson-Gaussian noise. However, most self-supervised methods rely on generic image statistics and do not explicitly model this noise, which may limit their ability to effectively suppress realistic LDCT noise. To address this issue, we propose a physics-driven framework with cross-domain iteration for self-supervised LDCT denoising. The proposed framework proceeds in three main steps. First, a learned sinogram prior and the LDCT noise model guide posterior inference of photon counts, enabling separation of the Poisson and Gaussian components. Second, the separated Poisson and Gaussian components are respectively processed by binomial thinning and Gaussian data thinning to construct two branches, and residual scaling matches each branch's noise level to that of the observation, yielding a training pair with approximately independent noise realizations from one low-dose measurement. Finally, the pair is used to train an image-domain network whose forward-projected outputs update the prior. Through cross-domain iteration, the prior and the training pair are progressively refined while maintaining consistency with CT acquisition physics. Experiments on simulated data from AAPM, LIDC-IDRI, and LoDoPaB-CT and on real LDCT data show consistent gains over the evaluated self-supervised baselines across dose levels, with performance comparable to the evaluated supervised baseline.

0.25

Unified Projection-Domain Material Decomposition for Energy-Integrating and Photon-Counting CT

eess.IV physics.med-ph ·2026-10-21 ·Dale Black, Surya Naidu, Hamidreza Khodajou-Chokami, Sabee Molloi
theory similarity 0.57
Abstract · 27 pages, 10 figures, 6 tables

Objective: To develop a unified and efficient method for projection-domain material decomposition in spectral computed tomography (CT) that incorporates an arbitrary number of spectral measurements, independent of the acquisition mechanism, without reducing the measurements to two effective energies. Approach: A nested optimization method was developed for two-material basis decomposition from K>=2 spectral measurements. It extends an existing two-measurement univariate method by replacing its polynomial approximation with profile minimization of the Poisson negative log-likelihood, reducing the inversion to two one-dimensional searches that use all measurements without spectral rebinning. The method was evaluated in simulation for energy-integrating (GE Revolution Apex Elite, Siemens SOMATOM Flash) and photon-counting (Siemens NAEOTOM Alpha) CT. Main results: The method recovered line integrals with noiseless iodine errors below 3e-6 g/cm^2 and noise within 3% of the Cramer-Rao lower bound (CRLB). Virtual monoenergetic images (VMIs) agreed, at 70 keV and above, with reference CT numbers and, on all three systems, with vendor VMIs of physical scans (mean absolute error 6-22 HU). For photon counting, four measurements instead of two reduced the iodine CRLB by 19% and image noise by 8-16% at every VMI energy, and lowered the regression error at 70 keV and above. Iteration and tolerance settings changed CT numbers by less than 0.04 HU, and decomposition took 0.34-0.67 s per million rays on an A100 GPU. Significance: The method provides fast, accurate decomposition for any spectral CT acquisition mechanism and number of measurements, so one method can serve every scanner in a virtual imaging trial.

0.25

LIPS-PC: Learning Illumination Patterns for Single-Pixel Classification

cs.CV physics.opticscs.LG ·2026-11-03 ·Tomer Porat, Talya Eden, Eliahu Cohen
unusual similarity 0.56
Abstract · 9 pages, 8 figures, comments are welcome

In single-pixel (ghost) imaging, known illumination patterns probe an object and a detector with no spatial resolution returns one number per pattern. Each measurement costs acquisition time and photons and, for ionizing probes, contributes to delivered dose. Motivated by automated radiographic defect screening, where a class label suffices, we introduce Learning Illumination Patterns for Single-Pixel Classification (LIPS-PC). The patterns are learned end-to-end while the measurement operator remains one fixed linear matrix, identical for every input. We parameterize it as a residual correction to a two-dimensional discrete cosine transform (2D-DCT), $D=D_{\mathrm{base}}+Δ$, and jointly train the correction and a compact classifier using cross-entropy, without a reconstruction objective. This yields a task-driven linear embedding through optimization. We evaluate LIPS-PC numerically on MNIST and Fashion-MNIST under a controlled protocol, then on RIAWELC, a real industrial X-ray weld-radiograph dataset. Across five budgets, $M\in{8,16,32,64,128}$, corresponding to sampling ratios from below 1% to 12.5%, the learned operator outperforms the best tested fixed transform by 9-15 percentage points at $M=8$ on all three datasets. Its eight-measurement accuracy requires roughly 16-32 measurements with the best fixed transform, indicating a $2\times$ to $4\times$ saving at comparable accuracy. The advantage generally shrinks as $M$ increases, with a small reversal on RIAWELC at higher budgets. These results show that learning what to measure is especially valuable when measurements are scarce.

0.29

Bayesian Joint Reconstruction and Uncertainty Quantification for Limited-Data Multi-Contrast X-Ray CT

eess.IV physics.optics ·2026-10-15 ·Hassan Yazdanian, Henrik Mäkinen
similarity 0.54
Abstract

Multi-contrast X-ray computed tomography (CT) combines attenuation contrast with phase and dark-field contrast, which are sensitive to refraction and ultra-small-angle scattering, respectively. Common implementations record several intensity measurements per projection angle by phase or mask stepping, which lengthens acquisition and, at a fixed exposure per measurement, raises the dose. Limited-data acquisition via sparse angular sampling or reduced stepping lowers these costs but makes the data less informative, calling for prior information and uncertainty quantification. We study joint Bayesian reconstruction of attenuation, phase, and dark-field images from separately retrieved sinograms. A joint total variation term in the prior couples edge locations across the images but not their values. Posterior sampling with the No-U-Turn Sampler complements maximum a posteriori estimates with pixel-wise uncertainty. We compare this joint prior with channel-wise total variation alone on synthetic and experimental Talbot-Lau interferometry data under full, sparse-angle, sparse-step, and combined acquisition (up to 24 times fewer exposures). Both maximum a posteriori reconstructions suppressed undersampling artifacts, with synthetic relative errors 1.6-11 times lower than those of filtered backprojection. The joint prior gave modest synthetic accuracy gains, a cleaner experimental dark-field background, 23-30 % lower mean dark-field posterior standard deviation, and 4-38% higher median effective sample size in experimental limited-data runs. In the synthetic study, posterior standard deviations matched or exceeded the errors in flat regions but underestimated them at boundaries, especially in phase. Experimental phase chains mixed slowly under angular undersampling. The formulation also applies to edge illumination with adapted forward and noise models.

0.20

Model-Based Iterative Reconstruction with View-Dependent Detector Displacements for Cone-Beam CT

eess.IV ·2026-09-18 ·Doga Topcicek, Sharmin Majumder, Whitney A. Poling, Dmitriy D. Bruder, Zhili Feng +2 more
similarity 0.54
Abstract · 5 pages, 5 figures

Detector shifting is used in industrial cone-beam computed tomography to reduce ring artifacts, but the resulting detector motion can vary nonuniformly across projection views and produce detector positions that cannot be represented by fixed offsets. Although analytical reconstruction can accommodate this motion, approaches that use projection interpolation or rebinning may limit spatial resolution and introduce artifacts. MBIR provides an alternative by representing the acquisition geometry explicitly within the reconstruction model. Existing separable distance-driven MBIR formulations assume fixed detector geometry across projection views and therefore cannot directly represent nonuniform motion in both detector dimensions, as this motion changes the voxel-to-detector mapping. We extend the separable distance-driven MBIR model to incorporate recorded horizontal and vertical detector displacements into the distance-driven overlap computation while leaving measured projections unchanged. Forward-projection validation achieved an NRMSE of 0.0338 across 1080 views. The proposed model achieved a 3D SSIM of 0.9404 and NRMSE of 0.0406, compared with 0.5396 and 0.1740 for fixed-detector MBIR. A second industrial dataset showed reduced structured artifacts compared with FDK.

0.41

Informed Sinogram Interpolation for Sparse View Reconstruction

eess.IV ·2026-09-16 ·Yuejie Liu, Alessandro Lupoli, David Uribe Gallo, Andreas Fischer, Felix Krahmer
similarity 0.54
Abstract

Computed tomography (CT) has been widely used in medical examinations and non-destructive testing. Micro-CT (microfocus X-ray CT system) is an advanced version that can observe the internal structures of small objects. However, secondary radiation can prevent micro-CT from imaging the full structure of the object. Given the same amount of secondary scans as primary scans, simple subtraction solves the problem at the price of doubled acquisition time. To reduce the acquisition time, one aims to limit the secondary scans to as few imaging angles as possible and interpolate to recover the missing data. Different interpolation methods have been explored for limited-angle tomography, such as polynomial or spline interpolation, compressive sensing, deep learning, etc. In contrast to many of these scenarios, the secondary imaging setup considered in this paper often exhibits simple sinusoidal structures that are not exploited directly by any of the aforementioned approaches. This paper aims to fill this gap with a continuous mathematical model describing the secondary sinogram only with information from the projection space. Building on this model, we propose an interpolation method that effectively interpolates secondary scans from limited observations.

0.27

Differentiable Jitter Correction using Deep Learning-based Image Quality Metric for Phase-Contrast Micro-CT

cs.CV ·2026-08-27 ·Junan Chen, Yiting Jia, Joscha Maier, Dominik John, Sami Wirtensohn +4 more
similarity 0.53
Abstract

This paper proposes a fully differentiable jitter correction method for X-ray phase-contrast micro computed tomography using a deep learning-based image quality metric that estimates and compensates per-projection rigid jitter directly from the acquired projection data, without a pre-scan motion-free reference. The approach builds on a gradient-based auto-focus strategy adapted to parallel-beam geometry. A set of candidate objective functions is benchmarked in a controlled study, and the sensitivity of the visual information fidelity (VIF) metric to the jitter artifact is verified with the target phase-contrast data. To operate without a clean reference, a compact 3D convolutional neural network is trained to predict the VIF score from a single corrupted volume. A spatially selective total variation penalty applied exclusively to the image background is introduced to penalize spurious high-frequency structures that otherwise emerge during optimization. Experiments on biological specimens acquired at different synchrotron beamlines are conducted. Evaluation uses jitter motion applied to simulated and experimentally acquired projection data. The result confirms that the integrated pipeline reliably recovers fine structural detail lost due to jitter, with generalization demonstrated across morphologically distinct samples.

0.21

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

cs.CV cs.AIphysics.med-ph ·2026-10-29 ·Alzahra Altalib, Chunhui Li, Alessandro Perelli
code/datahot direction similarity 0.53
Abstract · 10 pages, 4 figures, 8 tables

Cone beam computed tomography (CBCT) is widely used for image guided and adaptive radiotherapy, but scatter, noise, reconstruction artifacts, and inaccurate Hounsfield units limit its quantitative use. Recent diffusion approaches for CBCT to CT synthesis remain largely image driven, with limited use of the underlying acquisition physics. We propose EPC-RawDC, a conditional 3D latent diffusion framework that combines volumetric generative modeling with two complementary constraints derived from the same scanner specific CBCT forward model. First, geometry equivariant projection constraint exploits the rotational equivariance of the CBCT forward operator by supervising the synthesized CT through correspondingly transformed reference projections. Second, raw data consistency uses noisy projection measurements of the individual acquisition as scan specific supervision during training. The framework was evaluated on two independent clinical cohorts with distinct scanner geometries and projection sources. For JUST, the physics constraints used measured clinical raw CBCT projections acquired with an Elekta system, whereas for SynthRAD2025 the projection data were simulated from the reference CT using a Varian geometry with Poisson photon statistics. EPC-RawDC achieved an SSIM of 0.97 in both cohorts and improved PSNR over DDPM by 2.66 dB on SynthRAD2025 and 2.10 dB on JUST, while reducing mean MAE by 20.3% and 19.0%, respectively. On SynthRAD2025, projection consistency and equivariant errors were reduced by 55.0% and 41.4% relative to DDPM. These results demonstrate that combining a volumetric diffusion prior with scanner geometry and scan specific projection measurements improves quantitative CBCT to CT synthesis across both simulated and measured projection domains. Code available after publication at https://github.com/ALZAHRAALTALIB/EPC-RawDC.

0.37