CS Paper Radar

Bayesian Joint Reconstruction and Uncertainty Quantification for Limited-Data Multi-Contrast X-Ray CT

Hassan Yazdanian, Henrik Mäkinen

eess.IV physics.optics ·submitted 2026-10-15 07:24 UTC · v1

Abstract

Multi-contrast X-ray computed tomography (CT) combines attenuation contrast with phase and dark-field contrast, which are sensitive to refraction and ultra-small-angle scattering, respectively. Common implementations record several intensity measurements per projection angle by phase or mask stepping, which lengthens acquisition and, at a fixed exposure per measurement, raises the dose. Limited-data acquisition via sparse angular sampling or reduced stepping lowers these costs but makes the data less informative, calling for prior information and uncertainty quantification. We study joint Bayesian reconstruction of attenuation, phase, and dark-field images from separately retrieved sinograms. A joint total variation term in the prior couples edge locations across the images but not their values. Posterior sampling with the No-U-Turn Sampler complements maximum a posteriori estimates with pixel-wise uncertainty. We compare this joint prior with channel-wise total variation alone on synthetic and experimental Talbot-Lau interferometry data under full, sparse-angle, sparse-step, and combined acquisition (up to 24 times fewer exposures). Both maximum a posteriori reconstructions suppressed undersampling artifacts, with synthetic relative errors 1.6-11 times lower than those of filtered backprojection. The joint prior gave modest synthetic accuracy gains, a cleaner experimental dark-field background, 23-30 % lower mean dark-field posterior standard deviation, and 4-38% higher median effective sample size in experimental limited-data runs. In the synthetic study, posterior standard deviations matched or exceeded the errors in flat regions but underestimated them at boundaries, especially in phase. Experimental phase chains mixed slowly under angular undersampling. The formulation also applies to edge illumination with adapted forward and noise models.

Closest papers

Nearest neighbours by meaning across the whole index.

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.64
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

Generative Translation Priors: Bayesian Imaging with Cross-Modality Image Translation

eess.IV cs.CVcs.LG ·2026-08-28 ·Evan Bell, Jiaming Liu, Yifan Chen, Yu Sun
code/data similarity 0.64
Abstract · 51 pages, 12 figures. Code is available at https://github.com/Hopkins-CIG/GTP

The ability to leverage images from co-available modalities to inform target-domain reconstruction is highly desirable in imaging algorithms. In this work, we introduce Generative Translation Priors (GTP)--a Bayesian framework that transforms diffusion-based image-to-image translation models into cross-modality image priors for ill-posed imaging inverse problems. GTP incorporates target-domain measurements through likelihood guidance, steering the translation process toward the desired posterior distribution. The framework is grounded in a theoretical analysis of the resulting posterior dynamics, which reveals an intrinsic bias introduced by likelihood guidance. We further characterize this bias and derive a ground-truth-free formulation for its estimation, enabling it to serve as a practical metric for assessing posterior sampling quality. Building on this analysis, we derive two discretized GTP algorithms based on gradient and proximal likelihood guidance, respectively. We validate GTP on computed tomography reconstruction with magnetic resonance side information, and on positron emission tomography reconstruction with computed tomography side information. Experiments demonstrate that GTP effectively incorporates complementary cross-modality information and achieves high-fidelity reconstruction even under severely undersampled measurements.

0.38

Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CT

eess.IV cs.LG ·2026-10-05 ·Honglei Brinkmann, Carola-Bibiane Schönlieb, Ander Biguri
similarity 0.64
Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time and may mitigate motion artifacts. However, angular undersampling provides insufficient information to determine the image uniquely and stably. Limited-angle CT, arising from restricted angular coverage, produces strongly directional information loss associated with the missing angular range. In both settings, image directions may be strongly observed, weakly constrained, or unobservable, leading to severe ill-posedness and reconstruction ambiguity. Existing diffusion-based approaches incorporate measurement information through likelihood guidance, data-consistency operations, or range-null-space corrections. However, they do not generally use the continuously varying measurement sensitivity of the acquisition to jointly shape both reconstruction updates and stochastic exploration. We propose a geometry-aware diffusion-guided stochastic reconstruction framework for sparse-view and limited-angle CT. Its central component is a regularized noise-weighted pullback metric constructed from the CT forward operator and measurement-noise covariance. This metric continuously adapts both the measurement-aware update and stochastic exploration according to directional measurement sensitivity, suppressing changes along strongly constrained directions while permitting greater exploration along weakly constrained and unobservable directions. We complement this geometry-aware update with a regularized data-consistency correction and approximately null-space-restricted stochastic perturbations, implemented matrix-free using forward and backprojection operations together with conjugate-gradient solves. Experiments on sparse-view, noisy, and limited-angle CT demonstrate competitive reconstruction quality, strong measurement consistency, and spatially resolved empirical uncertainty estimates.

0.22

Consecutive Posterior Fusion for Diffusive Recovery of Unobservable Image Structures

cs.CV cs.AI ·2026-10-02 ·Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
similarity 0.62
Abstract · 21 pages, 7 figures, 2 tables

Solving severely ill-posed imaging inverse problems requires recovering image structures that are unobservable or weakly constrained by the measurements. Diffusion models provide expressive learned priors for inferring such missing information, while posterior sampling incorporates measurement consistency along the reverse process. Standard diffusion posterior samplers, however, rely on instantaneous measurement-aware estimates, without explicitly exploiting information carried by previous posterior corrections. We introduce Consecutive Posterior Fusion Denoising Diffusion Null-Space Models (CPF-DDNM), an inference-time strategy that fuses consecutive measurement-aware estimates to improve the diffusive recovery of unobservable image structures, without requiring retraining or additional denoiser evaluations. We instantiate this principle within DDNM, whose range/null-space decomposition reveals that consecutive fusion preserves the measurement-determined component while acting exclusively on the prior-driven null-space estimate. We thus provide a geometric interpretation of CPF-DDNM and a local error analysis that characterizes the optimal time-dependent fusion coefficient, including the extrapolative regime. Experiments on sparse-view and simulated low-dose computed tomography, as well as medical image super-resolution, show consistent improvements over DDNM and competitive performance against diffusion-based inverse solvers.

0.14

Bayesian PET Reconstruction with Learned Flow Matching Priors via Langevin Sampling

eess.IV cs.CV ·2026-10-30 ·Hengjia Ran, Huafeng Liu, Bo Zhao
benchmark similarity 0.62
Abstract · Selected as the Best Student Paper Award for 2026 IVMSP

Image reconstruction for positron emission tomography (PET) is a challenging inverse problem due to its inherent ill-posedness and Poisson counting noise, particularly in low-dose acquisitions. In this work, we introduce a novel Bayesian PET reconstruction framework that leverages a flow-matching generative prior learned from high-quality PET images. By incorporating this prior, we formulate PET reconstruction as a Bayesian inference problem and solve it via latent-space posterior sampling using the unadjusted Langevin algorithm. We evaluate the proposed method through numerical experiments and benchmark it against classical reconstruction methods and state-of-the-art deep learning-based baselines. The proposed method achieves improved reconstruction performance while enabling posterior uncertainty quantification.

0.45

Differentiable Jitter Correction using Deep Learning-based Image Quality Metric for Phase-Contrast Micro-CT

cs.CV ·2026-08-27 ·Junan Chen, Yiting Jia, Joscha Maier, Dominik John, Sami Wirtensohn +4 more
similarity 0.62
Abstract

This paper proposes a fully differentiable jitter correction method for X-ray phase-contrast micro computed tomography using a deep learning-based image quality metric that estimates and compensates per-projection rigid jitter directly from the acquired projection data, without a pre-scan motion-free reference. The approach builds on a gradient-based auto-focus strategy adapted to parallel-beam geometry. A set of candidate objective functions is benchmarked in a controlled study, and the sensitivity of the visual information fidelity (VIF) metric to the jitter artifact is verified with the target phase-contrast data. To operate without a clean reference, a compact 3D convolutional neural network is trained to predict the VIF score from a single corrupted volume. A spatially selective total variation penalty applied exclusively to the image background is introduced to penalize spurious high-frequency structures that otherwise emerge during optimization. Experiments on biological specimens acquired at different synchrotron beamlines are conducted. Evaluation uses jitter motion applied to simulated and experimentally acquired projection data. The result confirms that the integrated pipeline reliably recovers fine structural detail lost due to jitter, with generalization demonstrated across morphologically distinct samples.

0.21

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.62
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

Informed Sinogram Interpolation for Sparse View Reconstruction

eess.IV ·2026-09-16 ·Yuejie Liu, Alessandro Lupoli, David Uribe Gallo, Andreas Fischer, Felix Krahmer
similarity 0.62
Abstract

Computed tomography (CT) has been widely used in medical examinations and non-destructive testing. Micro-CT (microfocus X-ray CT system) is an advanced version that can observe the internal structures of small objects. However, secondary radiation can prevent micro-CT from imaging the full structure of the object. Given the same amount of secondary scans as primary scans, simple subtraction solves the problem at the price of doubled acquisition time. To reduce the acquisition time, one aims to limit the secondary scans to as few imaging angles as possible and interpolate to recover the missing data. Different interpolation methods have been explored for limited-angle tomography, such as polynomial or spline interpolation, compressive sensing, deep learning, etc. In contrast to many of these scenarios, the secondary imaging setup considered in this paper often exhibits simple sinusoidal structures that are not exploited directly by any of the aforementioned approaches. This paper aims to fill this gap with a continuous mathematical model describing the secondary sinogram only with information from the projection space. Building on this model, we propose an interpolation method that effectively interpolates secondary scans from limited observations.

0.27