CS Paper Radar

Advances in Modeling Techniques for Ventricular Assist Devices: A Comprehensive Review and Future Directions

Muhammad Adel Yusuf, Nezar M. Alyazidi, Hamna Saleem, Ali Nasir, Mojeed Oyedeji

eess.SY ·submitted 2026-09-17 14:58 UTC · v1

Abstract

Ventricular Assist Devices (VADs), particularly rotary Left Ventricular Assist Devices (LVADs), are essential for patients with advanced heart failure who are ineligible for transplantation. Despite advances in cardiovascular modeling and control, clinical translation of proposed LVAD control methods remains limited. This review examines the evolution of LVAD modeling and control and argues that the gap results not from insufficiently sophisticated algorithms, but from mismatches between modeling assumptions, sensing limitations, and real-world cardiovascular variability. A systematized review of more than 100 peer-reviewed studies covers mathematical cardiovascular models, lumped-parameter and reduced-order representations, classical and advanced control strategies, and emerging data-driven and machine learning approaches. The literature is synthesized using a problem-driven framework linking modeling and control choices to clinical challenges, including physiological observability, parameter identifiability, patient variability, and prevention of adverse events such as ventricular suction and thrombosis. The analysis shows that high-fidelity models and intelligent controllers can perform well in simulation, but their dependence on unmeasurable states, extensive parameter tuning, and dense sensing limits clinical implementation. Simpler control approaches often provide greater robustness under clinical constraints. Adaptive and data-driven techniques may help bridge this gap, but only if they account for implantable sensing limitations and interpretability requirements. By identifying structural barriers to adoption, this review synthesizes LVAD modeling and control paradigms and outlines research directions for physiologically adaptive, clinically implementable, and patient-safe LVAD systems.

Closest papers

Nearest neighbours by meaning across the whole index.

Efficient physiological control of an integrated system architecture for continuous-flow ventricular assist devices: in-silico study

eess.SY eess.SP ·2026-09-21 ·Bruno J. Santos, Idagene A. Cestari
similarity 0.65
Abstract

This study presents the development and in silico evaluation of an Integrated System Architecture (ISA) for the physiological control of continuous-flow ventricular assist devices (VADs). The system employs an automatic controller based on pressure measurements at the VAD inflow cannula to estimate heart rate and ventricular filling pressure, enabling dynamic speed adjustments that optimize VAD-patient interaction. The evaluation encompassed 27 simulation scenarios assessing four aspects: operating speed regulation, responsiveness to variable demand, adverse event mitigation, and physiological impact. The controller continuously adapted to preload, afterload, and heart rate, accommodating flow demands with speed adjustments ranging from -10% (-600 rpm) to +43% (+2,600 rpm) relative to the baseline (6,000 rpm). Furthermore, dynamic regulation eliminated ventricular suction and backflow events, which were previously observed in 12 of the 27 uncontrolled scenarios. Hemodynamic and metabolic outcomes demonstrated improved left ventricular ejection fraction (+6.23% to +62.31%), reduced ejection work (-1,658.64 to -206.37 mmHg*mL), decreased pressure-volume loop area (-9,485.17 to -1,056.05 mmHg*mL), and reduced myocardial oxygen consumption (-20.5 to -1.14 mL/min). Concurrently, total oxygen delivery increased (+56.9 to +626.23 mL/min) along with cardiac power (+100 to +3,070 mW). These findings demonstrate that the ISA successfully maintains physiological regulation and mitigates adverse events, establishing a solid foundation for future in vitro validation.

0.18

Adaptive Uncertainty-Aware Modeling and Stochastic Radial Basis Function Predictive Control for Personalized Fluid Resuscitation

eess.SY cs.LG ·2026-09-18 ·Elham Estiri, Hossein Mirinejad
similarity 0.55
Abstract

This paper presents a novel framework integrating Bayesian physiological modeling with optimal control strategies to achieve uncertainty-aware, personalized hemodynamic regulation during fluid resuscitation. An uncertainty-aware variational autoencoder state-space model (UVAE-SSM) was first developed to capture the dynamical relationship between mean arterial pressure (MAP) and fluid infusion using limited data, while explicitly modeling aleatoric uncertainty (i.e., randomness in the measurements, such as sensor noise). Then, a Bayesian nonlinear state-space model (BNSSM) was developed by utilizing Bayesian neural networks (BNNs) to capture epistemic uncertainty arising from physiological and patient-specific variability, enabling the creation of a virtual patient generator (VPG). Building on this uncertainty-aware modeling framework, a stochastic radial basis function model predictive control (sRBF-MPC) algorithm was designed to track the MAP target while satisfying physiological constraints. Finally, an online fine-tuning algorithm was developed to adapt the nominal UVAE-SSM using streaming VPG data, enabling progressive personalization during closed-loop therapy. Simulation results across unseen animal subjects and an independent human clinical dataset demonstrated the strong predictive accuracy and cross-population generalizability of the UVAE-SSM and BNSSM models. Closed-loop evaluations confirmed that the proposed sRBF-MPC framework achieved stable MAP regulation while providing better risk-aware control compared to quadratic MPC (Q-MPC) and stochastic quadratic MPC (sQ-MPC). Overall, the proposed framework accounts for inter- and intra-patient variability through online model adaptation, offering a promising step toward uncertainty-aware, personalized hemodynamic modeling and control in critical care.

0.26

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.55
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.53
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.16

Learning from VAE Errors to support ECG-based Differential Diagnosis of Myocardial Scar

cs.LG stat.ML ·2026-09-04 ·Shayan Sharifi, Riccardo Treu, Ilaria Gandin, Federico Garoia, Marco Merlo +1 more
similarity 0.52
Abstract · Accepted at the PharML Workshop, ECML PKDD 2026

Late Gadolinium Enhancement (LGE) on cardiac magnetic resonance is a key marker of myocardial scar, but its limited accessibility motivates routine ECG-based screening. We evaluated whether $β$-variational autoencoder (VAE)-derived ECG representations can discriminate LGE+ from LGE- cardiomyopathic patients in a local cohort of 300 subjects. We compared 32-dimensional features from the foundation ECGx.AI model with those from a shallower $β$-VAE trained on normal PTB-XL ECGs, evaluating downstream classification and Dynamic Time Warping (DTW)-based reconstruction errors. ECGx.AI reached an area under ROC of 0.686 with Random Forest, while the proposed $β$-VAE reached 0.577 with sensitivity of 0.775 with Gradient Boosting. Notably, DTW-reconstruction errors significantly differed between classes in 10 out of 12 leads according to Mann-Whitney U test and help in classification, leading to an area under ROC of 0.643 with Logistic Regression, supporting their potential as markers of scar-related ECG alterations.

0.22

A Vision Transformer for ECG-Based Detection of Left Ventricular Systolic Dysfunction Across Multiple Clinical Sites

cs.CV cs.LG ·2026-08-12 ·Burcu Ozek, Aruna Mohan, David Vorchheimer, Daniel Weiss, Eyal Kedar +3 more
similarity 0.52
Abstract · 19 pages, 5 figures, 5 tables; includes supplementary material with 3 additional figures

Reduced left ventricular ejection fraction (LVEF) is frequently asymptomatic and often detected only after advanced heart failure develops. Electrocardiograms are recorded routinely yet underused for this condition, because reduced LVEF has no single diagnostic waveform. We trained an ensemble of vision transformers from scratch to detect reduced LVEF ($\leq$40%) from 12-lead ECGs, analyzing each heartbeat individually, using 10,142 patients across seven sites in three US health systems. In a held-out external cohort of 4,092 patients from three geographically independent US clinical sites at a real-world reduced-LVEF prevalence of 8.72%, the model achieved an AUROC of 0.88 (95% CI 0.86-0.89), sensitivity 81.2%, specificity 81.0%, and negative predictive value 97.8%. Sensitivity remained high across sex, race, ethnicity, and comorbidity subgroups, while specificity was lower in older patients and those with atrial fibrillation or cardiomyopathy. Beat-level attention maps provided interpretability into the model's predictions, showing consistent focus on the QRS complex rather than the P wave. These findings support the potential of routine ECGs as a scalable first-pass triage step to identify patients who should undergo echocardiography for reduced ejection fraction across diverse patient populations.

0.10

Shaft-Configuration-Adaptive Catheter Tip Position Estimation via Motor-History Conditioned Residual Learning

cs.RO eess.SY ·2026-09-22 ·Peihan Zhang, Michael C. Yip, Ankur Kapoor, Young-Ho Kim
similarity 0.51
Abstract

Tendon-driven continuum manipulators are widely used in medical applications, where accurate tip-position estimation is essential for precise navigation and instrument positioning. However, patient anatomy and procedural setup impose task-dependent unknown shaft configurations, while friction, slack, and compliance introduce hysteresis, making tip estimation challenging. This paper presents a motor-history-conditioned gated recurrent unit (GRU) residual estimator for three-dimensional catheter tip estimation without direct shaft-configuration sensing. First, an initial multidirectional sweep strategy is applied to calibrate a geometric catheter model backbone, and encode the motor-angle and drive-torque response into a shaft-configuration context vector. During subsequent motion, the context conditions a GRU that predicts a task-space residual correcting this backbone, relying on motor measurements alone. The context remains fixed for the current shaft configuration, while the recurrent state captures the evolving actuation history. Across four disposable intra-cardiac echocardiography catheters and 16 bent shaft configurations, the method achieves 3.3mm open-loop tip RMSE, a 59% reduction relative to the constant-curvature baseline.

0.39

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.50
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17