CS Paper Radar

CTSpinoPelvic1K: spine, pelvis, ribs and femora in one coordinate frame, annotated for lumbosacral transitional anatomy

Gregory Schwing, Ashley Schehr, Annika Tekumulla, Margret Khoushi, Ryan Christian, Dane Hubers, Faris Mahjoub, Hassan Saad, Mia Sooch, Sathyagopal Siddapureddy, Michael McLellan, Jerick Kim, Miraziz Ismoilov, Nizar Alnabahneh

cs.AI cs.LG ·submitted 2026-09-19 04:41 UTC · v1
code/dataunusual

Abstract

Purpose: A vertebra at the lumbosacral junction is named by counting caudally from C2 on whole-spine imaging, but a lumbar case is planned on lumbar-only imaging (T12 to S1), without C2. Abdominopelvic CT holds that span plus the lowest ribs and pelvis. Where a lumbosacral transitional vertebra (LSTV) alters the count, the local anatomy is ambiguous: four rib-free vertebrae may be an L1 with a lumbar rib or an L5 assimilated to the sacrum, and six may be a sixth lumbar vertebra, a T12 with aplastic ribs, or a lumbarized S1. CTSpinoPelvic1K asks whether local morphology resolves it without the count. CTSpine1K's vertebrae and CTPelvic1K's pelvis covered these patients but were never joined; this release joins them on one series and adds the bones neither had. It provides 802 CT records with per-level ribs and femora, levels anchored on the lowest rib-bearing vertebra and S1, and classes for L6, T13, a separate S1 and lumbar ribs, so anomalies are recorded as such. Acquisition and Validation Methods: Records pair CTSpine1K and CTPelvic1K labels on each patient's bone-richest series under a VerSe-native scheme. Validation covered geometric invariants (802/802 pass), rib-vertebra incidence across 5,749 ribs (0.035% offset), and spinopelvic measures matching published values. Data Format and Usage Notes: NIfTI image/label pairs with patient-grouped LSTV-stratified five-fold splits and a loader; archived at https://doi.org/10.5281/zenodo.22139642. Potential Applications: Classifying a vertebra from local features; updating cadaveric morphometry; spinopelvic assessment; opportunistic screening; and, absent a public preoperative lumbar cohort, surgical planning research (377 records prone). Limitations: thoracic ground truth is field-of-view limited; postural angles supine; no held-out test set; ribs are triaged-review pseudolabels; Castellvi grades two-reader consensus on 33 records.

Comment
14 pages, 6 figures, 6 tables. Dataset (802 annotated CT records, CC BY-NC-SA 4.0) at https://doi.org/10.5281/zenodo.22139642; code at https://github.com/OpenSpineConsortium/CTSpinoPelvic1K. Submitted to Medical Physics as a Medical Physics Dataset Article

Closest papers

Nearest neighbours by meaning across the whole index.

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

eess.IV cs.CVq-bio.TO ·2026-10-12 ·Quan Wang
benchmarkcode/data similarity 0.49
Abstract

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

0.37

Raysemble: Metric 3D Bone Reconstruction from a Single X-ray

cs.CV ·2026-11-12 ·Xiaoyang Li, Xinghao Yan, Yuan Chai
similarity 0.44
Abstract

Raysemble reconstructs eight lumbar and pelvic bones from a single X-ray by separating shape and placement. Each 3D query samples regional and global features at its image projection. A shared decoder predicts normalized bone shapes. Predicted depth and camera geometry determine 3D centers and scales for resampling these shapes onto a common grid in millimeters. Evaluation uses 23 held-out patients with 43 CT scans, each generating one simulated anteroposterior radiograph. Without rigid alignment to CT,Raysemble leads 15 evaluated methods, averaging 65.24% Dice, 9.09 mm HD95, and 3.32 mm ASSD over three random seeds. With identical inputs, it improves Dice over VolumeNeRF by 5.86 percentage points.

0.23

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

cs.CV ·2026-10-15 ·Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
top venue similarity 0.43
Abstract · This version was submitted to MICCAI 2026 for review, see journal reference for published version

Markerless intraoperative tracking of spinal anatomy via RGB-D sensors is a promising alternative to invasive bone-anchored fiducials, yet no existing clinical dataset provides independent subsurface ground truth for validating these methods. We address this gap with a clinically viable pipeline that derives per-vertebra 6-DoF pose from routine intraoperative C-arm fluoroscopy, co-registered to the RGB-D camera frame through a multimodal fiducial array detectable in both imaging modalities. Critically, the pipeline requires no additional radiation, instrumentation, or deviation from standard surgical workflows, relying solely on the fluoroscopic images already acquired during routine level checks. A calibrated transform chain links the vertebral pose recovered via multi-view 2D-3D CT-to-fluoroscopy registration to the RGB-D coordinate frame, enabling direct comparison of any markerless registration estimate against a subsurface reference. Ex vivo validation against optically tracked ovine vertebrae confirms end-to-end accuracy of 2.06 +- 0.29 mm and 3.35 +- 0.93 degrees, sufficient to serve as independent ground truth for methods with substantially larger errors. We demonstrate the pipeline's utility by evaluating two markerless registration strategies on clinical data spanning 11 vertebrae across 1,500 frames from three surgical sequences: the first such evaluation against an independent subsurface reference in a clinical setting. The proposed framework provides reusable infrastructure for benchmarking emerging markerless tracking methods on real surgical data.

0.42

Learning to Reason Like a Cytopathologist:Clinically Grounded Multiscale Evidential Learning for Cervical Cytology

cs.CV ·2026-10-21 ·Ajeet Kumar Singh, Nehal Mishra, Anurag Tripathi, Santanu Chaudhury, Dorien Herremans
similarity 0.39
Abstract

Cervical cytology presents a fundamentally ambiguous diagnostic landscape, where equivocal categories such as Atypical Squamous Cells of Undetermined Significance (ASC-US) occupy a morphological grey zone that is definitional. For clinical decision support, the goal extends beyond assigning a definitive label to every sample: cases must also be distinguished by whether the available evidence supports a confident decision or warrants further consideration, a distinction conventional classification models are not designed to explicitly represent. We propose a multiscale evidential framework that models cervical cytology along an ordinal disease continuum using clinically grounded soft anchors, representing progression from benign reactive changes to precancerous lesions and malignancy. Three biologically motivated spatial contexts--nuclear morphology, cytoplasmic characteristics, and neighbourhood cellular architecture--are independently encoded using a shared frozen DINOv2 backbone, preserving inter-scale disagreement that early fusion may obscure. Calibrated predictions are transformed into Dempster--Shafer belief masses and fused with reliability discounting, allowing conflicting evidence and insufficient support to remain explicitly uncommitted rather than forcing a decision. The fused belief state drives interpretable routing that separates confidently classified cases from those with irreducible evidential insufficiency, enabling clinically meaningful triage. Across two independent publicly available conventional cytology datasets, RIVA and CRIC Cervix, the framework generalises consistently, with uncertainty strongly associated with diagnostic difficulty: incorrect predictions carry 1.94x-4.13x higher uncertainty than correct ones.

0.23

MRI-to-CT Translation of Spinal Images via Anatomy-Guided Pseudo-Pairing and Adversarial Diffusion

cs.CV cs.AI ·2026-10-27 ·Eduardo Nieto, Ibai Genua, Davide Scorza, Karen López-Linares
similarity 0.39
Abstract

Magnetic Resonance Imaging (MRI) is routinely used to diagnose spinal disorders, but surgical planning often requires Computed Tomography (CT) for better visualization of vertebral bone anatomy. Synthesizing CT from MRI could avoid additional radiation exposure and streamline preoperative assessment. We propose a three-stage framework for spine MRI-to-CT synthesis. First, an anatomy-guided vertebral matching system identifies similar sagittal MRI and CT slices using spine segmentations and aligns them through rigid registration, creating pseudo-paired data from unpaired scans. Second, these pairs train an adversarial diffusion model for MRI-to-CT translation. Third, synthesized slices are assembled into 3D volumes and refined by a network that improves inter-slice continuity and structural coherence. The framework was trained on over 10,000 unpaired sagittal MRI and CT slices and evaluated on 1,911 slices from 83 MRI volumes spanning all spinal regions. Assessment combined distribution-based measures with vertebral segmentation metrics. Compared with diffusion alone, the proposed approach increased binary 3D vertebral Dice from 0.666 to 0.739. Volumetric post-processing reduced visible discontinuities between stacked slices and improved vertebral coherence in axial and coronal views. Combining anatomy-guided pseudo-pairing, adversarial diffusion and 3D refinement improves spine MRI-to-CT synthesis. Vertebral matching primarily enhanced anatomical alignment and fidelity, while volumetric refinement improved 3D consistency. These findings support further development of MRI-derived CT-like visualization for preoperative planning, particularly to preserve fine intensity details while maintaining volumetric coherence.

0.16

Spinal Coupling in Frontal and Transversal Plane During Gait - A Segmental and Time-Dependent Analysis of the Thoracic and Lumbar Spine

cs.CE ·2026-08-13 ·Jonas Dully, Carlo Dindorf, Henriette Rönsch, Dennis Perchthaler, Jürgen Konradi +2 more
similarity 0.39
Abstract

Introduction: Coupling between lateral deviation and axial rotation is a known feature of spinal mechanics, yet its behavior at the individual vertebral level during gait, as well as the association with sagittal posture remains poorly understood. Methods: This study analyzed spinal kinematics in a diverse cohort (n=642) using a non-invasive rasterstereography system with an instrumented treadmill, quantifying time-dependent coupling of rotation and lateral deviation for each vertebra from T3 to L4 during walking as well as the influence of sagittal posture on this coupling. Coupling behavior was analyzed with absolute phase lag, normalized signed area and tilt angle derived from the Fourier series. Results: Results revealed cranio-caudal patterns for all three metrics with differences between almost all adjacent vertebrae and different turning points, i.e., where the coupling behavior changed (from increase to decrease and vice versa). Generalized, as well as pooled static sagittal posture significantly modulated these patterns, while individual deviations from static sagittal posture influenced the metrics. Conclusion: These findings provide the first dynamic, vertebra-level characterization of spinal coupling during gait. Furthermore, they offer a foundation for an understanding of spinal biomechanics and the influence of static sagittal posture, potentially relevant to the diagnosis and treatment of spinal disorders.

0.04

Dense Representation Learning and Differentiable Shape Modeling for Spine Landmark Detection

cs.CV cs.AI ·2026-10-27 ·Augustin Daridon, Sofiane Sifaoui, Ayman Assi, Mohamad Karam, Wafa Skalli +2 more
code/data similarity 0.38
Abstract

Spine landmark detection from spinal X-ray is a key step for estimating spine deformation severity, for building biomechanical models, and for pre-operative planning. We reframe anatomical landmark detection as a pixel-level contrastive representation learning problem, matching dense pixel embeddings with landmark prototypes. Surprisingly, even with a generic U-Net backbone, this formulation results in more discriminative heatmaps compared to the traditional heatmap regression paradigm, leading to improved discrimination between vertebral corners on distinct vertebra. Furthermore, we combine the resulting heatmaps with learnable shape priors over the global configuration of spinal landmarks to resolve ambiguities in landmark locations, yielding a simple and practical approach to spinal landmark detection. Our approach is competitive, in terms of landmark accuracy and clinical parameter estimation, with the state-of-the-art on the public AASCE dataset and on two private spinal X-ray datasets. Our code and pre-trained weights are available at https://github.com/BioMedTP/Pix2Point.

0.33

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

eess.IV cs.CV ·2026-11-03 ·Bowen Xiang, Michael I. Miga
similarity 0.38
Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

0.23