CS Paper Radar

Heating in human-HVAC interaction for smart homes: An interdisciplinary overview

Delong Korus-Du, Gunnar Stevens, Alexander Boden, Lenneke Kuijer, Apostolos K. Vavouris, Md Shajalal, Philip Engelbutzeder, Omid Veisi, Peter Tolmie

cs.HC cs.AIcs.SIeess.SY ·submitted 2026-09-20 09:48 UTC · v1
published

Abstract

As part of HVAC systems, residential heating provides foundational infrastructure for human habitation in cold weather. However, research on how residents interact with HVAC systems, particularly heating systems, remains fragmented across architecture, engineering, informatics, physiology, psychology, sociology, and design. Based on 541 studies from these fields, this review integrates interdisciplinary research on Heating in Human-HVAC Interaction in smart homes.The resulting synthesis is conceptualized through the Situated Interaction Dynamics of control and feedback between users and systems. User-initiated interactions involve monitoring past and present system performance and planning future operation, while system-initiated interactions rely on sensor networks to trigger automation or provide information enabling user action. These interaction dynamics connect Residents' Experience and Practices with Heating in HVAC System Mechanics. Residents' Experience and Practices include thermal comfort and energy management, where thermal comfort involves both individual physiological and psychological experiences of indoor climate and social practices shaped by norms, empathy, and negotiation among cohabitants. Heating in HVAC System Mechanics includes thermal conditions and energy performance. Thermal conditions concern the regulation of air temperature, mean radiant temperature, air velocity, and relative humidity, while energy performance concerns efficiency and environmental impact. This overview highlights four interdisciplinary tensions: sensed versus lived conditions, personalization versus negotiation, efficiency versus health, and automation versus agency. The resulting framework offers a conceptual lens to interpret heating interactions and design Human-HVAC Interaction that balances IEQ-driven healthy thermal conditions, affordability, and sustainability.

Journal ref
Building and Environment, 2026, 115220
DOI
10.1016/j.buildenv.2026.115220

Closest papers

Nearest neighbours by meaning across the whole index.

Designing for Healthy, Affordable, and Sustainable Human-HVAC Interactions for Heating in Smart Homes

cs.HC cs.CYcs.MMcs.SI ·2026-09-07 ·Delong Korus-Du
published similarity 0.78
Abstract

As geopolitical tensions, energy crises, and energy-intensive AI infrastructure intensify concerns about demand, affordability, and resilience, communities increasingly encounter these challenges through everyday energy practices, particularly winter heating. Against this background, the doctoral exposé, "Designing Human-HVAC Interaction for Healthy, Affordable, and Sustainable Heating in Smart Homes", is structured around four chapters. First, a multidisciplinary literature review defines and positions Human-HVAC Interaction, focusing on heating in smart homes. Second, longitudinal living lab studies with design probes examine everyday heating practices, thermal comfort, and indoor environmental quality, with attention to thermally vulnerable groups such as older adults, pregnant or menopausal women, parents with infants, and people affected by allergies or airborne pollutants. Third, a VR-based smart home demonstrator explores how heating and IEQ scenarios can be prototyped and evaluated as a virtual living lab, while critically examining the limits of representing bodily indoor climate conditions through VR. Fourth, follow-up design studies examine how VR-based insights can be translated into physical-digital prototypes that combine digital fabrication, distributed environmental sensing, and diverse interface forms for critical heating and IEQ contexts. The thesis aims to contribute a design-oriented understanding of Human-HVAC Interaction by building from a multidisciplinary literature review to empirical living lab and co-design studies, VR-based prototyping, and physical system development, examining how smart home users make sense of, negotiate, and respond to smart HVAC system.

0.72

From Thermal Preference Prediction to Adaptive Thermal Intervention: A Reinforcement Learning Approach Using Physiological and Environmental Sensing

cs.LG cs.AI ·2026-08-19 ·Isibor Kennedy Ihianle, Emmanuel Manu, Ehsan Asnaashari, Mojgan Jadidi, Pedro Machado +2 more
similarity 0.63
Abstract

Personalised thermal comfort is essential for occupant wellbeing and for the development of more responsive building-control strategies, yet conventional Heating, Ventilation, and Air Conditioning (HVAC) systems rely on static setpoints and population-level comfort models that fail to capture individual physiological variability. This paper presents a two-stage personalised thermal comfort approach integrating multimodal physiological and environmental sensing with reinforcement learning-based decision-making.

0.26

A sensor-driven physics-informed neural network for real-time occupant-centric space heating control

cs.LG eess.SY ·2026-11-01 ·Yunfei Bai, Chenghao Li, Sunku Prasad Jenne, Hao Wang, Sizhe Zhang +1 more
similarity 0.58
Abstract

Conventional space heating systems typically rely on single or sparse fixed-point temperature measurements, overlooking non-uniform indoor temperature distributions, transient thermal dynamics, and occupant-specific comfort requirements. This study explores an occupant-centric control strategy that aims to maintain the desired temperature around the occupant location. Spatially and temporally varying temperature fields, together with occupant mobility, make real-time local temperature estimation challenging. To address this challenge, we propose a control-oriented Physics-Informed Neural Network (PINN) model for indoor temperature-field prediction. Conventional PINNs rely on explicit time inputs and assume consistent temporal patterns across samples, which limits adaptability under variable initial conditions and heating sequences. The proposed model infers temporal dynamics implicitly from spatial coordinates and limited sensor measurements, improving robustness to changes in initial conditions and external disturbances. The method was validated across nine horizontal sensing planes in three controlled room-scale configurations. Against a validated COMSOL Multiphysics simulation, the PINN predicted the evaluated temperature fields with a maximum relative error below 1.85% across validation cases. These predictions supported an occupant-centric space heating control scheme. Compared with COMSOL-based offline control, the PINN-based system achieved an average prediction error of around 0.67%, and its rapid inference supports real-time occupant-centric control implementation. This work represents a move away from reliance on fixed-point temperature measurements in space heating control to an occupant-centric control strategy informed by real-time environmental feedback.

0.24

Large Language Models for HVAC Operations in Building Energy Systems: A Critical Review of Methods, Applications, and Deployment Readiness

cs.AI cs.CLeess.SY ·2026-09-04 ·Alexander Neubauer, Tianzhen Hong, Han Li, Mengbo Yu, Amin Darbandi +2 more
survey similarity 0.57
Abstract · 38 pages, 9 figures, 16 tables. Submitted to Energy and Buildings

Building automation systems generate rich sensor data yet remain insight-poor because heterogeneous point naming, missing metadata, and fragmented documentation obstruct their operational use. This systematic review analyses and codes 66 peer-reviewed studies on large language models (LLMs) for HVAC operations published between 2023 and March 2026. Each study is classified across five application families and three LLM method families and assessed for evidence realism, deployment readiness, and the responsibility boundary between the LLM and physical HVAC decisions. The corpus is concentrated in building energy modelling (BEM, 32 of 66 papers), while load forecasting remains too sparse for subfield-level conclusions. Only four studies reach pilot-level evidence, and none reports sustained operational deployment. No study was classified as ready-now for industry adoption; three were near-term and 63 research-only. Nevertheless, several bounded, human-in-the-loop uses merit near-term trials, including point-name normalisation, document-grounded operator support, BEM workflow assistance, and advisory interfaces around physics-based controllers. Conventional machine learning (ML), model predictive control (MPC), reinforcement learning (RL) and ontology-based tools remain more adopted for high-frequency control, short-horizon numerical forecasting, and well-posed ontology mapping, while autonomous agentic operation and unvalidated occupant proxies remain research-stage. Current evidence therefore supports LLMs primarily as semantic and workflow layers rather than autonomous HVAC controllers. Future work should prioritise field-validated benchmarks, orchestration evaluation under operational constraints, and LLM-MPC/RL architectures with bounded latency and verifiable safety properties.

0.60

Data-driven estimation of design heating loads for HVAC equipment sizing

eess.SY ·2026-09-07 ·Alex H. Lee, Elias N. Pergantis, Kevin J. Kircher
similarity 0.57
Abstract

Oversized heating and cooling equipment can unnecessarily increase up-front costs, energy costs, pollutant emissions, and strain on electrical infrastructure. This paper develops two data-driven methods for estimating heating loads at design conditions to improve equipment sizing. One method uses smart thermostat data; the other uses utility bills. We test the methods on a dataset that we gathered from 74 detached single-family houses in five United States climate zones. The dataset includes smart thermostat time-series data, monthly utility bills, weather data, existing equipment specifications, and Manual J design load calculations (the United States industry standard) purchased from practitioners. The two methods have strong goodness-of-fit statistics individually and show fair agreement with each other. On average over the 74 houses, existing heating equipment is 2.75 (2.5th to 97.5th empirical percentile: 1.34-6.52) times larger than the thermostat-method estimate and 2.96 (1.36-7.76 times larger than the bill-method estimate. As implemented by practitioners, the Manual J estimate is 2.26 (0.87-5.21) times larger on average than the thermostat-method estimate and 2.35 (1.02-5.28) times larger than the bill-method estimate. We discuss prospects for implementing the data-driven methods at scale and for incorporating data-driven sizing into industry standards.

0.26

Climate Physicalization: Bridging Tangible Interaction and Data Visualization for Environmental Communication

cs.HC ·2026-10-15 ·Milena Vuckovic, Marlene Huber, Fabrizia Bando-Bechtold, Daniel Cornel, Daniel Pahr
similarity 0.55
Abstract · 10 pages

Raising awareness of climate topics, such as urban heat mitigation, requires communicating complex data to a broad audience. Data physicalization has emerged as a novel method to connect audiences to such complex topics through tangible forms while also leveraging interactivity to foster deeper engagement. This paper introduces an situated geospatial thermal physicalization prototype, designed to enhance communication and education of environmental information through hands-on engagement. The physical model depicts a 3D model of an urban neighborhood, with radiation data represented as a layered contour structure. The model incorporates three interchangeable climate adaptation scenarios, alongside an externally mounted, electronically driven solar path representation featuring multiple discrete LEDs that can be switched on and off at will. To investigate how people engage with the model, we conducted a hands-on qualitative lab study with 16 participants, using think-aloud, observational, and questionnaire protocols. Overall, participants responded very favorably to the model, highlighting the novelty of the visualization approach and its capacity to improve the interpretability of the presented information.

0.24

Model-Free Control for Residential Heating: Deployment and Simulation of Nonlinear Data-Enabled Predictive Control

eess.SY math.OC ·2026-09-18 ·Sebastian Zieglmeier, Chris Verhoek, Jaap Eising, Mathias Hudoba de Badyn
similarity 0.55
Abstract · 19 pages, 8 figures, 7 tables

Residential heating accounts for a large share of building energy use, and predictive control strategies can reduce it by anticipating rather than reacting to the room temperature alone. The usual manner of implementing predictive control, model predictive control (MPC), requires an accurate model of each individual residential unit for heating control. Obtaining this model is time-consuming to obtain manually or even impossible, and such models do not transfer across a heterogeneous building stock. Data-enabled predictive control (DeePC) removes this modeling step by designing the controller directly using measured trajectories of the system. The foundations of DeePC, however, are built on the class of deterministic linear time-invariant systems, which is an unrealistic assumption for residential heating. This work applies three recently proposed nonlinear extensions of DeePC, collectively referred to as data-driven predictive control (DPC): Select-DPC, gain-scheduling DPC, and linear parameter-varying DPC. These are compared against standard DeePC and the hysteresis controller, the industry standard in residential heating. The comparison runs over a full heating season on a calibrated digital twin of an occupied research unit, the NEST research building in Switzerland, assessed by heating energy and comfort-band violation. Moreover, gain-scheduling DPC was deployed on the real residential apartment and validated the conclusions from the simulations. Each of the DPC controllers consumes significantly less energy than the hysteresis controller, amounting to roughly $11\%$ over the season, validating the use of DPC. The nonlinear methods further outperform linear DeePC in all assessed scenarios, and we analyze the relative costs and benefits of each nonlinear method.

0.41

ADAPT: Physics-Aware Diffusion-based World Models for Adaptive Predictive Transferable HVAC Control

cs.AI ·2026-08-20 ·Xu Yang, Kailai Sun, Dianyu Zhong, Qianchuan Zhao
similarity 0.55
Abstract

Buildings account for roughly one-third of global energy consumption and CO$_2$ emissions. Optimizing indoor climate systems plays a critical role for urban climate mitigation aligned with UN Sustainable Development Goals 11 and 13. However, indoor delayed thermodynamic responses and partial observability severely hinder existing methods, which are primarily limited by implicit thermal inertia, occupancy dynamic prediction, and cumulative prediction errors, especially for out-of-distribution environments. In practice, these challenges are further exacerbated by the high cost and privacy burden of dense indoor sensing, forcing operators to collect only limited data in a single operating regime while expecting controllers to generalize reliably across unseen seasons and climate regions. To address this problem, we propose ADAPT, a physics-aware conditional diffusion indoor environmental world model for HVAC control. The model predicts a short-horizon held-action thermal baseline to capture the latent thermal inertia of the buildings. The diffusion backbone utilizes the robustness of generative models, while a learnable multi-zone heat-balance regularizer constrains generated trajectories to satisfy transferable building thermodynamics without requiring known building geometry or manually calibrated thermal parameters. A credit assignment is then design for the downstream reinforcement learning. Extensive experiments on SemibuildingSim and Sinergym demonstrate that ADAPT reduces HVAC energy consumption by 7.3\% and occupant discomfort by 30.2\% compared with state-of-the-art baselines under IID control. Under OOD control scenarios spanning unseen seasons and climate regions, ADAPT maintains robust performance with only marginal degradation relative to its IID performance, substantially outperforming existing methods in transfer robustness.

0.23