Abstract

Advances in processing power, camera technologies, and mobile image analysis have made smartphones and other mobile devices, such as laptops, increasingly suitable for medical diagnosis and healthcare applications. Researchers have developed low-cost solutions for the early detection and monitoring of various health conditions, including eye and ENT diseases, malnutrition, heart rate variability, skin and oral conditions, and injuries, using images captured by non-medical devices such as smartphones and webcams. This survey examines existing research on mobile image-based medical diagnosis, with an emphasis on its potential to enable low-cost and accessible healthcare. We comparatively analyze state-of-the-art solutions across different healthcare application categories, examining their advantages and limitations. Based on this analysis, we identify desirable characteristics of mobile image-based diagnostic tools and highlight areas where existing approaches have made progress as well as areas requiring further research. We also discuss application-specific and common challenges and outline directions for future research. Overall, this study provides a comprehensive overview of mobile image-based healthcare solutions and their potential to support low-cost disease diagnosis and monitoring, particularly for underserved populations in remote and resource-constrained settings.

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Blur: A Semantic Tri-view Pipeline for Teledermatology Gradability via Skin Micro-relief

eess.IV cs.CVcs.HCcs.LG ·2026-09-02 ·Robert Engel
published similarity 0.60
Abstract

Smartphone skin photographs are indispensable to teledermatology, yet assessing the diagnostic suitability of submitted cases (gradability) remains a critical bottleneck in mobile care workflows. Dermatologists routinely review multiple photographic views (regional, angled, and close-up) to identify consistent textural detail rather than relying on a single image. We present the Semantic Tri-view Pipeline, an interpretable architecture for automated teledermatology gradability screening that formalizes epidermal micro-relief as a computable biomarker of image quality. Using an expert-annotated subset of the public SCIN dataset, we train a lightweight DeepLabV3+ model to segment micro-relief fidelity. These spatial masks are then aggregated across up to three case views with a logistic regression classifier, leveraging viewpoint redundancy to support robustness under uncontrolled smartphone acquisition. This approach learns context-aware, clinically intelligible heuristics, such as penalizing high-fidelity texture in regional distance views. Evaluated at a predefined 90% sensitivity operating point, the system's apparent errors largely reflect subjective clinical variance on borderline cases where clinicians rely on non-visual metadata. On SCIN, performance improves from an AUC of 0.81 (80.6% PPV) on variance-heavy majority-consensus cases to 0.96 (97.7% PPV) on optically unambiguous unanimous cases. Overall, this work delivers an interpretable, privacy-by-design, edge-ready system that can provide real-time feedback during case submission to filter ungradable photo sets before review.

0.40

GAMF-Net: Grouped Availability-Aware Multimodal Fusion for Smartphone Skin Lesion Classification

cs.CV ·2026-10-20 ·Yue Zhuo, Jingjia Yan, Fangyu Liu, Lingjun Liu, Zongjun Chen +2 more
published similarity 0.58
Abstract · 14 pages, 4 figures. Accepted at MMM 2027

Smartphone clinical images provide a low-cost data source for computer-aided skin lesion classification in resource-constrained settings, but images alone cannot fully capture patients' medical histories and lesion symptoms. To address the lack of structured organization among heterogeneous clinical variables, the ambiguity between observed and imputed values, and the risk that clinical information may interfere with visual evidence, we propose GAMF-Net, a grouped availability-aware multimodal fusion network. Ten clinical variables are divided into three semantic groups---demographics, history-related risk, and lesion presentation---and each group jointly encodes field values and field-level availability masks. The image branch produces the base classification logits, while each clinical group generates image-conditioned class-level residual evidence. Only available groups participate in availability-normalized equal-weight fusion; when all clinical information is unavailable, the model reduces exactly to the image-only pathway. We evaluate the method on PAD-UFES-20 under a patient-disjoint five-fold protocol with separate training, validation, and test partitions. GAMF-Net achieves an Accuracy of $74.17\pm2.85\%$, a balanced accuracy (BACC) of $70.11\pm2.11\%$, a Macro-F1 of $68.85\pm0.85\%$, and a Macro-AUROC of $93.42\pm1.20\%$, outperforming all image-only and multimodal baselines reimplemented under a unified protocol. Compared with the strongest baseline, MetaBlock, the corresponding improvements are 2.37, 2.59, 4.14, and 1.02 percentage points, respectively. Ablation results show that clinical information substantially improves class-balanced performance, constrained equal-weight fusion is more effective than dynamic fusion, and the lesion-presentation group provides the most informative clinical complement.

0.22

A Cloud-Edge System for Multimodal Clinical Screening in Resource-Constrained Rural Settings

cs.LG cs.DC ·2026-08-13 ·Hei Ting Chan, Chenwei Wu, Xueshen Liu, Zesen Zhao, Boyuan Zheng +5 more
top venue similarity 0.54
Abstract · 31 pages, 3 figures. In Proceedings of Machine Learning Research, Volume 340, 2026 (Machine Learning for Healthcare Conference)

Medical AI has demonstrated specialist-level diagnostic accuracy, yet these capabilities remain largely inaccessible in resource-constrained rural settings where bandwidth is scarce, compute is limited, and clinical decision-making requires integrating heterogeneous modalities. We introduce a cloud--edge collaborative architecture that addresses these constraints: lightweight, domain-specific models on the edge transform raw medical data into compact structured outputs, while a cloud LLM synthesizes these outputs into clinical summaries. An LLM-based orchestrator dynamically selects diagnostic tools based on patient context, promoting comprehensive modality coverage without processing irrelevant inputs. We evaluate on 20 multimodal clinical cases spanning cardiac, obstetric, trauma, and screening scenarios under three simulated network profiles (500,kbps--5,Mbps). The hybrid system achieves 98--99% diagnostic tool recall with 92--96% precision, matches or exceeds cloud-only baselines on clinical accuracy, and maintains bandwidth-invariant latency (25--35,s) at 4--15x lower token cost. These results highlight the role of architectural design in enabling efficient multimodal integration and improving factual grounding compared to cloud-only approaches under deployment constraints.

0.40

An Energy Efficient Wearable for Monitoring Elderly People Health

eess.SP cs.CY ·2026-08-26 ·M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto +1 more
similarity 0.54
Abstract · 8 pages, 11 figures

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

0.36

Validation of Smartphone-Based Photogrammetric 3D Body Scanning for Automated Anthropometric Measurements Compared with a Commercial Depth-Sensor-Based Body Scanner

cs.CV ·2026-08-13 ·Ruting Cheng, Boyuan Feng, Chuhui Qiu, Joaquin A. Calderon, Qing Pan +2 more
published similarity 0.54
Abstract · 16 pages, 5 figures, 4 tables

3D body scanning has become an important tool in healthcare applications because of its rapid and non-invasive nature. While smartphone-based photogrammetric reconstruction provide a low-cost and accessible alternative to commercial 3D body scanners, their performance for whole-body scanning remains insufficiently validated. Thus, we designed this study to comprehensively validate the photogrammetric 3D scanning application by evaluating automatically extracted whole-body measurements and longitudinal body-shape monitoring. We evaluated a representative application, PolyCam, against the commercial depth-sensor-based Fit3D ProScanner using 144 pregnant participants scanned longitudinally throughout pregnancy. We designed an automatic circumference extraction pipeline to get measurements at four anatomical landmarks from paired 3D scans. A linear mixed-effects model was used to evaluate scanner effects and longitudinal body-shape changes. Measurement consistency was assessed using repeated PolyCam scans and tape measurements on a rigid mannequin. PolyCam demonstrated strong agreement with Fit3D, with average biases below 16 mm, intraclass correlation coefficients above 0.8, and Pearson correlation coefficients above 0.9 across all landmarks. Both systems captured comparable longitudinal body-shape changes. Mannequin experiments showed mean biases below 3.5 mm and no significant differences from tape measurements. These findings support smartphone photogrammetry as a potential accessible alternative to commercial body scanners and applicable for longitudinal 3D body-shape assessment.

0.28

Robust Lightweight Deep Learning Models for Oral Cancer Screening

cs.AI ·2026-08-21 ·Siddhant Bharadwaj, Aakash Shedsale, Tejashree Subramanya, Mohd. Azfar, Praveen Birur +4 more
published similarity 0.54
Abstract · 10 pages, 3 figures, Paper accepted for the 6th International Conference on AI-ML Systems, 2026

Oral cancer is a leading cause of mortality in low-to-middle-income countries, where a shortage of specialists delays diagnosis. While point-of-care screening via smartphones offers a scalable solution, developing robust AI for resource-constrained settings poses significant challenges, including class imbalance in training data, variable data quality, and computational constraints on edge devices. In this paper, we present the optimisation of lightweight deep learning models for smartphone-based oral cancer screening. Using a diverse, multi-centre retrospective dataset of approximately 30,000 images acquired over a decade, we systematically evaluate state-of-the-art convolutional, transformer, and hybrid architectures. Through rigorous pipeline ablation, we demonstrate that directly optimising hybrid architectures for the edge strictly outperforms computationally heavy paradigms, such as large models or knowledge distillation. Furthermore, interpretability analysis and simulated noise-stress tests revealed that the system anchors on clinical features and remains robust to unstructured sensor noise, despite vulnerabilities to impulse bit errors. In the held-out test set, our optimised MobileViTv2 models achieved an average sensitivity of 83.2 $\pm$ 1.5% and an average specificity of 86.0 $\pm$ 0.8%, with the best model exhibiting 87.4% sensitivity, 86.5% specificity, and a critical negative predictive value of 97.2% with reference to specialist labels. These results confirm that with targeted architectural selection and streamlined optimisation, interpretable and robust lightweight AI models exhibit high potential for edge deployment to enable automated triage in primary care settings.

0.30

PhoneValue-Bench: A Multimodal Benchmark and Datasets for Consumer Smartphone Recommerce Valuation

cs.CV cs.AI ·2026-10-31 ·Zihan Deng, Jun Gao
benchmark similarity 0.53
Abstract

As consumer smartphone recommerce scales, buyers must quote binding repurchase prices from seller-uploaded multi-view photos and diagnostic screenshots before devices reach the warehouse. Accurate remote valuation requires fusing noisy cosmetic evidence with identity, battery, lock, and channel risk from screenshots and staff forms, since an error in any modality changes both grade and payout. However, existing multimodal resources mainly target general VLM competence, screen reading, or factory defect detection, and largely overlook staff-aligned trade-in fields, dual appearance/staff ground truth, and executable valuation scorecards. This gap stems from two challenges: (1) the lack of large-scale real trade-in data with audited dual annotations and a compact ranking benchmark kept separate from training labels, and (2) the need to jointly reason over unordered multi-view cosmetics and diagnostic screens under operational deduction rules. To address these challenges, we propose PhoneValue-Bench, a dual-GT evaluation suite with tier-gated scorecards, together with PhoneValue-Corpus, a matched weakly labeled training set of over twenty thousand orders and hundreds of thousands of captioned images. We further present ValueAgent, a staged perception-fusion-valuation reference pipeline aligned with production inspection, plus an executable public scorer and submission schema. Experiments show that ValueAgent reaches a measured 84.1/100 on Bench-Full, with 97.0 appearance fill and 54.1 staff-field fill, establishing a practical dual-GT benchmark for multimodal recommerce valuation.

0.32

RetinaSC: Retinal Semantic Communication Framework for Diabetic Retinopathy Detection

eess.SP ·2026-10-13 ·Avani Shinod, Rangineni Rushitha, Asqeem Nas, Anirban Bhowal, Shikha Baghel
similarity 0.52
Abstract

This paper presents a lightweight semantic com- munication framework for diabetic retinopathy (DR) grading from fundus images pertaining specifically to the APTOS2019 dataset. The framework includes semantic encoder designed using ResNet34, U-Net, MobileNetV2, and EfficientNet-B0 architectures. Further, the trained models are used to train the same framework for IDRiD dataset using transfer learning approach. Such a framework will enable the telemedicine sector in the early detection of DR and prevent total blindness. The results reveal that for APTOS, task-oriented semantic systems can achieve satisfactory robust performance (more than 0.8 weighted F1 score for ResNet34 and EfficientNet-B0) across different channels. In particular, considering the trade-off between complexity, latency, throughput, and F1 score, MobileNetV2 is the best model with weighted F1 score of 0.76-0.78 for both task and reconstruction- oriented modules and end-to-end latency of only 8.162 ms.