CS Paper Radar

DynaTrust-VVC: Directional Physics-Informed Trust-Based Detection and Mitigation for Cyber-Resilient Multi-Agent Volt--VAR Control

Md Fazley Rafy, Kamrul Hasan, Anurag K. Srivastava

eess.SY cs.MA ·submitted 2026-08-30 22:32 UTC · v1
published

Abstract

Distributed Volt--VAR control relies on voltage measurements and is therefore vulnerable to false-data injection. Neighbor corroboration can distinguish an isolated corrupted measurement from a physical disturbance, but coordinated agents can falsely corroborate one another. This paper proposes DynaTrust-VVC, a cyber-resilient multi-agent Volt--VAR framework that assigns each incoming neighbor message a directional trust value based on the consistency between its reported voltage increment and a sensitivity-based prediction from active- and reactive-power changes. Trust falls immediately after a physics mismatch and recovers gradually after sustained consistency. DynaTrust-VVC further uses a physics-adaptive evidence threshold and counterfactual safe-voltage recovery-based mitigation. The proposed method was validated using a nonlinear IEEE 123-bus feeder with minute-resolution residential profiles and 27 matched replicates. DynaTrust-VVC identifies a coordinated three-bus attack one minute after onset in all 27 matched replicates, whereas an otherwise identical configuration with fixed neighbor trust identifies none. The composite resilience index also increases from 0.227 to 0.315, with no statistically significant increase in the benign false-alarm rate.

Comment
6 pages, 2 figures and accepted in 2026 Cyber Awareness and Research Symposium (CARS)

Closest papers

Nearest neighbours by meaning across the whole index.

Agreement Is Not Assurance: Evidence-Independent Safety Gates for Agentic AI in DER-Rich Distribution Grids

eess.SY ·2026-11-11 ·Qianxue Xia
similarity 0.63
Abstract · 10 pages, 3 figures, 4 tables

Physics-based safety gates for large language model (LLM) agents can approve unsafe actions when the agent and gate rely on the same corrupted measurements or network records. We formulate this shared-evidence failure for voltage-constrained distributed energy resource (DER) export decisions and analyze how nearly critical DER telemetry can bias state estimation while evading residual-based bad-data detection. We propose evidence-independent verification (EIV), which combines advanced metering infrastructure (AMI) voltage readings, measurement selection based on predicted voltage rise, and bounded physical probes. An IEEE 123-bus hidden-truth testbed evaluates 1,654 near-limit requests under telemetry attacks and record errors. For telemetry attacks targeting the nominal gate, an AC-twin gate with bad-data detection approved 95% of unsafe requests, compared with 3.1% for EIV; EIV rejected 22% of safe clean requests. At matched false-rejection settings, direct AMI checks outperformed incorporating the same readings into state estimation. Gate-targeted attacks exposed a vulnerability in telemetry-based response prediction. Command-based prediction removed that route, but targeted attacks on fresh validation cases still produced a 20% unsafe-approval rate under the tested attack pool. LLM agents frequently sought independent evidence voluntarily, but injected instructions and phase-label errors caused unsafe decisions. When offered the EIV checker as a tool, they used it in 93-100% of episodes; mandatory use did not reduce observed violations, which primarily reflected checker errors. These results distinguish enforcement of verification from reliability of the verifier itself.

0.27

RESILAGENT: A Three-Pillar Architecture for Cyber-Physical Resilience in Electrical Power and Energy Systems

cs.CR cs.AIeess.SY ·2026-11-16 ·Nikolaos Kekatos, Georgios Koutidis, Konstantinos Antonakopoulos, Stylianos Basagiannis, Sokratis Katsikas +4 more
publishedbenchmark similarity 0.60
Abstract · 7 pages, 5 figures, 1 table. Accepted at the 2026 IEEE International Conference on Cyber Security and Resilience (IEEE CSR 2026)

Electrical Power and Energy Systems face hybrid threats that combine cyber intrusions, physical sabotage and climate-driven stress, and routinely outpace today's siloed monitoring stacks. We present RESILAGENT, a concept architecture organised around three operational pillars, Sensing & Data Intelligence, Resilience Analytics & Reporting, and Incident Response & Recovery, mediated by a Cloud-based Orchestrator and exercised through a closed Detect-Simulate-Decide-Sign loop. The framework fuses agentic artificial intelligence and multimodal large language models for cross-modal detection, real-time digital twins for what-if simulation, and a permissioned blockchain anchor for tamper-evident threat intelligence and CER/NIS2-aligned evidence. We instantiate it on two scenarios, a transmission operator under coordinated cyber compromise, sabotage and heatwave, and a distribution operator under a supply-chain compromise during a storm, and report an IEEE-bus micro-benchmark that quantifies each pillar through false-data-injection attack detection, cyber-physical fusion lift, N-1 contingency screening and anchor cost.

0.44

Adversarially-Informed Node Criticality Identification in Power Grid Measurements

eess.SY math.OC ·2026-08-27 ·Koto Omiloli, Olugbenga Moses Anubi
similarity 0.58
Abstract

Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most severe system-level impact. However, existing node criticality methods primarily rely on structural or steady-state analyses and do not explicitly account for adversarial effects on system behavior. To address this gap, this paper proposes an adversarially informed framework for identifying critical measurement nodes in linearized power systems. Within this framework, a structured attack generation mechanism is developed to construct stealthy and effective false data injection attacks (FDIAs) against an H-infinity resilient state estimator. Node criticality is then evaluated using coalition-based marginal contributions of compromised sensor subsets, estimated via permutation sampling over a prescribed set of admissible nodes, with the resulting importance scores mapped to the corresponding physical buses. Simulation results on the IEEE 14-bus system show that adversarially identified nodes induce larger deviations in frequency, voltage angle, and net power compared to randomly selected nodes, demonstrating the effectiveness of the proposed framework.

0.23

Critical Weather Scenario Screening Using Weather-to-Voltage (W2V) Predictive Modeling

eess.SY ·2026-08-24 ·Sol Lim, Min-Seung Ko, Hao Zhu
published similarity 0.56
Abstract · 6 pages, 2 figures. Accepted to IEEE SmartGridComm 2026

This paper proposes a critical weather scenario screening framework for identifying weather conditions that can trigger high-voltage (HV) events in the power grid. Unlike conventional weather-aware contingency analysis limited to component-level outage risk, our framework screens weather scenarios as potential drivers of grid-level voltage violations. Given a non-critical weather scenario, we seek the perturbation over the high-dimensional weather space to maximize a pre-defined voltage criticality score, by using a differentiable weather-to-voltage (W2V) predictive model to facilitate the gradient update over a compact latent space. Specifically, a non-negativity constraint is used for achieving physically-consistent perturbations, with another L1-norm based constraint for bounded perturbation. The latter could promote sparse and interpretable perturbations, and this uniform budget also yields a sensitivity-aware vulnerability ranking across different weather scenarios. Numerical experiments on a 6717-bus synthetic Texas system have effectively demonstrated the potential of weather uncertainty in triggering HV events, and this potential cannot be represented by the voltage analysis of individual weather scenarios. Interestingly, the most vulnerable scenarios are characterized by wind-dominated perturbation patterns concentrated in high wind-capacity regions, coinciding with observations from actual power flow data and experiences in real system operations.

0.40

Hierarchical Sensor-Spoofing Defence Framework for Networked DC Microgrids via Cyber-Physical Coordination

eess.SY ·2026-08-13 ·Mengxiang Liu, Xin Zhang, Shiyi Zhao, Ruilong Deng
top venue similarity 0.56
Abstract · IEEE TSG

In parallel to the cyber attack that manipulates the reference points of distributed energy resources (DERs) by maliciously accessing the remote monitoring and control system, the vulnerability of voltage/current sensors to electromagnetic interference (EMI) in the physical domain has been widely discussed. Existing research efforts against sensor spoofing attacks can be classified into physical prevention and cyber detection/mitigation. These defence methods each have strengths and weaknesses in balancing cost, security, and performance in a single DER, yet systematic research on their multi-layer efficient coordination across DERs remains limited. Towards this end, this paper proposes a hierarchical framework to detect and mitigate sensor spoofing attacks in networked microgrids (NMGs) via {multi-layer cyber-physical coordination}. It requires only to deploy physical prevention technologies at critical points, i.e., the local points of common coupling (PCC) of MGs, such that cyber detection/mitigation algorithms can be adopted based on the secured sensor readings to counter sensor spoofing attacks in DERs. The framework employs an MG-DER coordinated proactive detection scheme to strategically trigger parameter perturbations, under which the intelligent sensor spoofing attacks can be {effectively} disclosed. Afterwards, mitigation schemes based on MG-DER coordination are activated to recursively and accurately estimate sensor biases. Experiments on a cyber-physical DC NMG testbed confirm the framework's effectiveness across diverse attack scenarios.

0.29

Interpretable Cyber-Physical Attack Detection in Smart Grids: A Leakage-Controlled Multi-Testbed Evaluation of Fusion, Robustness, and Observability Limits

cs.LG cs.AIcs.CR ·2026-11-07 ·Muhammad Ridwanul Hoque, Sarah Sharif, Reza Saeed Kandezy, Yaser Banad
code/data similarity 0.55
Abstract

Cyber-physical smart-grid detectors are typically treated as black boxes and validated exclusively on clean, temporally shuffled datasets, which risk overly optimistic performance claims. This work presents a multi-testbed evaluation study built around an interpretable, time-windowed fusion Random Forest, adopting the pessimistic result whenever evaluation protocols disagree. (i) On a public paired cyber-physical dataset, shuffled cross-validation is optimistic: macro-F1 falls from 0.96 to 0.88 +/- 0.06 under rolling-origin temporal evaluation. A topology-free graph convolutional network (GCN) serving as a control confirms that this lightweight model is competitive on these splits. (ii) The adaptive and adaptive-joint feature-space attacks, which are infeasible as realistic grid manipulations, degrade macro-F1 to 0.67 and 0.34, respectively. Adversarial training and randomized smoothing partially restore performance, and a physics-constrained evolution-strategy evasion on the IEEE 14-Bus testbed shows the same vulnerability pattern. (iii) On real IEC-104 traffic, the cyber view reliably catches structural attacks (recall of 0.87 to 0.98) but largely fails on semantic value manipulation (recall of 0.11 to 0.35). An observability taxonomy on the IEEE 14-Bus system reveals that stealthy false data injection defeats all three observation views. (iv) On a full AC weighted least-squares state-estimation testbed, a forecasting-aided temporal test is evaded by slow ramps precisely where a rate-invariant physics-manifold test sustains detection at a common 5% false-alarm target. A full end-to-end evaluation on IEEE 118-Bus confirms the ordering but bounds its strength: the manifold test detects every trial down to 0.05 degree/step and 0.48 at 0.02 degree/step, against 0.14 for the temporal test. All code and benchmarks are released.

0.38

Reducing Data-Center Load Transfers with Ride-Through-Aware Voltage Control

eess.SY ·2026-11-05 ·Siyu Lu, Yang Weng
similarity 0.55
Abstract · 10 pages, 5 figures

Fault-induced transfers of large data centers to backup supply can cause abrupt reductions in grid-served demand. Coordinating reactive-power support to mitigate these transfers requires consideration of facility-specific voltage--duration ride-through characteristics, particularly when support capacity is limited. This paper develops a ride-through-aware extension of quadratic voltage control that assesses voltage deviations relative to the admissible margins specified by these characteristics. We establish four design requirements that jointly express envelope-based severity, duration dependence, and preventive voltage-restoration incentives. Within a multiplicatively gated quadratic class, we derive necessary and sufficient conditions for satisfying these requirements and construct an explicit family of envelope-normalized objectives. We apply the proposed objectives to reactive-power coordination and evaluate their performance on the IEEE 14-bus, New England 39-bus, and NPCC 140-bus systems. Comparisons with Volt/VAR control, conventional nominal-voltage tracking, and recent data-center voltage-control methods demonstrate improved data-center retention under matched reactive-power support constraints. In the IEEE 14-bus study, the proposed controller reduces the mean data-center disconnection rate by 44.8\% and grid-demand loss by 27.4\% compared with the best-performing baseline. These results highlight the benefit of incorporating data-center ride-through requirements into reactive-power allocation.

0.50

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.54
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04