CS Paper Radar

STAMP: Predicting Out-of-Distribution Generalization without Target Data

Md Kawsher Mahbub, Milon Biswas

cs.LG cs.AI ·submitted 2026-09-26 14:28 UTC · v1

Abstract

Predicting whether a trained model will generalize under distribution shift remains difficult, especially when target-domain data are unavailable. We introduce STAMP (Semantic Temporal Augmented Model Prediction), a source-only, target-label-free criterion that estimates out-of-distribution (OOD) performance from paired source-domain images. STAMP computes the output-space correlation ratio $η^2=S_B/S_T$ by contrasting semantically stable pairs with random pairs: higher $η^2$ indicates that model outputs vary with semantic identity rather than nuisance variation. On 44 chest X-ray models spanning CNNs, ViTs, MetaFormers, foundation models, and SSL/VLM probes, temporal STAMP attains Spearman correlations of $0.844$--$0.855$ with macro AUROC on VinDr-CXR, CheXpert, and MIMIC-CXR; a class-matched variant improves single-class RSNA from $0.311$ to $0.663$. STAMP attains the best average source-only medical ranking and outperforms the target-domain ATC and AoTL estimators without any target data. On 27 ImageNet models, temperature-scaled STAMPTS attains $ρ{=}0.984$ on ObjectNet and $ρ\geq0.905$ on four additional distribution shifts, with partial correlations of $0.662$--$0.949$ after controlling for ImageNet accuracy. Requiring approximately 12s per model on one GPU, STAMP is a practical pre-deployment model-selection and auditing tool.

Closest papers

Nearest neighbours by meaning across the whole index.

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

cs.CV ·2026-08-26 ·Juan Iñaki Larrea, Lucas Mansilla, Enzo Ferrante
published similarity 0.67
Abstract · Accepted at MIRASOL Workshop, MICCAI 2026. 10 pages, 3 figures

Foundation models are increasingly deployed for medical image analysis. However, under the inter-institutional distribution shift typical of deployment, their performance varies widely and cannot be known without target-domain labels, which are rarely available. This leaves a practical question unresolved: given several candidate foundational models and labeled-data from a source domain, which one to deploy in an unlabeled target domain? We propose a label-free selection criterion built on SUDO, a framework for evaluating clinical AI systems without ground-truth annotations. SUDO partitions the unlabeled target data by predicted probability and, for each region, measures a pseudo-label discrepancy reflecting class contamination; aggregated across regions, this yields a score (AURCC) requiring neither target annotation nor fine-tuning. We show that AURCC can be used to rank a variety of vision-language models (BioMedCLIP, CXR-CLIP, CheXzero, MedCLIP, MedImageInsight, CLIP) on chest X-ray classification across three inter-hospital shift scenarios, under zero-shot and MLP-probe regimes. The AURCC ranking recovers the ground-truth ranking with Spearman rho up to 0.943 (p<0.05). Against the natural baseline of ranking by held-out source accuracy, AURCC is competitive when the labeled source is large and yields a more accurate ranking once it is small; the regime of interest in resource-constrained settings.

0.19

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/data similarity 0.64
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.63
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

From Adults to Children: Benchmarking Foundation Models for Chest X-Ray Classification under Domain Shift

cs.CV ·2026-10-15 ·Sara Inácio, Hugo Proença, João C. Neves
publishedbenchmark similarity 0.63
Abstract · Accepted at WACV 2027

Foundation models have shown significant potential across diverse fields and have been applied to medical imaging, but their robustness across patient populations remains unclear. In this work, we investigate foundation models' ability to generalize from adult to pediatric chest X-ray classification. To the best of our knowledge, this is the first benchmark to compare multiple foundation models under a common adult-to-pediatric evaluation setting while also analyzing the effect of adaptation depth. We harmonize VinDr-CXR and PediCXR into a five-label classification task and evaluate six foundation models and two CNN baselines. All models are adapted using adult data only and tested in both the in-domain and pediatric domains using linear probing, partial fine-tuning, and full fine-tuning. The benchmark reveals a clear and consistent trend: all models suffer a substantial performance degradation when transferred from adult to pediatric data, with drops exceeding 10 percentage points. While Macro-AUROC values reach approximately 92% on the adult test set, performance decreases to around 78% on the pediatric domain. Another important finding is that increasing the depth of adaptation improves pediatric performance on average, although the effect varies across models. Moreover, strong in-domain performance does not necessarily indicate greater robustness to domain shift.

0.40

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.62
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

Federated LoRA Adaptation of BiomedCLIP Across Four International Chest X-Ray Cohorts

cs.LG cs.AIcs.CV ·2026-09-02 ·Sanjaya Poudel, Nirajan Kunwor, Manish Dhakal, Debesh Jha, Sunil Kumar Gaire
benchmark similarity 0.62
Abstract

Federated learning (FL) lets institutions train a shared model without exchanging data, and Low-Rank Adaptation (LoRA) makes this practical at scale by communicating only compact low-rank updates. Biomedical imaging is a compelling setting for this combination: patient data are archived behind privacy regulations, and institutions differ widely in scanners, protocols, and compute. Such heterogeneity raises the question of how federated LoRA updates should be aggregated, increasingly pressing as multimodal vision-language models become central to medical image analysis. We benchmark federated Parameter-efficient fine-tuning (PEFT) of BiomedCLIP for chest radiograph classification across four public cohorts on three continents (USA, Vietnam, Spain). Federated LoRA adaptation improves shared-class AUC on all four cohorts over the unadapted BiomedCLIP backbone (mean 0.687 to 0.802), showing that the gains come from federated adaptation rather than from the pretrained model's zero-shot ability. Relative to isolated single-cohort training, federation improves the weaker cohorts while largely preserving the strongest and approaches a centralized reference (0.812) that pools all data. The singular value decomposition (SVD)-based product-space aggregation introduced by FlexLoRA is essential to this gain (naive factor averaging drops mean AUC by 0.097), whereas a drift-correcting optimizer (FedProx) shows no benefit over FedAvg in our single-seed runs, consistent with LoRA's low-rank updates already limiting client drift. Biomedical vision-language models can thus be adapted collaboratively across heterogeneous, geographically distributed institutions without centralizing data.

0.11

Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset

cs.CV cs.AI ·2026-09-23 ·Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang +4 more
benchmarkcode/data similarity 0.62
Abstract

X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on https://github.com/Event-AHU/Medical_Image_Analysis

0.32

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.61
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.12