CS Paper Radar

Is your uncertainty map wrong, or is its target? Exact diagnostics for the Tweedie diagonal, and a gradient-free alternative

Vicent Ribas, Anna Oliveras Tous

cs.AI ·submitted 2026-09-27 17:32 UTC · v1
unusual

Abstract

A diffusion model can predict a follow-up medical scan from a baseline, but a clinician needs a per-voxel map of where that prediction can be trusted. Many such maps approximate the diagonal of the Tweedie posterior covariance, and are evaluated against another approximation of it, so whether the estimator or the target limits them is unclear. We compute the exact diagonal on six checkpoints across fourteen model-corpus conditions. Hutchinson at M=200 tracks it at rank agreement of at least 0.92 everywhere, yet in four of the fourteen the exact diagonal is anti-correlated with the denoising error, reaching -0.13, so a faithful estimator reproduces that reversal. All four are real-image conditions; on the models' own samples the reversal does not appear, so evaluating on generated samples flatters this family. What limits these maps is the target, not the estimator. We then introduce Tweedie Probe-Tangent (T-PT), a gradient-free residual probe that corrupts one model-supported prediction repeatedly and measures the voxel-wise variance of the denoiser's response. T-PT reads a different functional of the same Jacobian, and its exact second-order form ranks with the diagonal wherever the diagonal reverses; at thirty probes it returns a map too unstable to reproduce that ranking, while Hutchinson at M=5 already reproduces it, so T-PT there is not evidence against the reversal. We offer it as an instrument, not a better approximation. On brain MRI at full resolution, where every Jacobian-based estimator we test runs out of memory, T-PT leads a twenty-chain Monte-Carlo ensemble on five of eight endpoints inside tissue and trails it on none, at 16x fewer network evaluations; over the whole volume the ensemble leads, and fifty chains close the tissue gap. On lung CT the ensemble is ahead throughout. Both lose most of their discrimination where the change is, which remains open.

Comment
40 pages, 3 figures, 23 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Evaluating and Calibrating Diffusion Model-derived Uncertainty for Quantitative MRI Mapping

cs.CV ·2026-08-12 ·Shishuai Wang, Stefan Klein, Juan A. Hernandez-Tamames, Dirk H. J. Poot
published similarity 0.53
Abstract · 11 pages, 6 figures. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imaging (UNSURE…

Quantitative MRI (qMRI) provides standardised tissue parameter maps, but the reliability of deep learning-based qMRI mapping methods is often not explicitly characterised. In this work we systematically evaluate uncertainty maps for quantitative MRI derived from multiple inferences of a data-consistent diffusion model-based qMRI framework. Evaluation on synthetic test data assessed error-awareness, high-error detection, selective prediction, and Gaussian interval calibration. Diffusion model-derived uncertainty was positively associated with the mapping error, while risk-coverage analysis showed that excluding high-uncertainty voxels reduced the retained error. However, the raw uncertainty was poorly calibrated for quantitative interval interpretation. Calibration was substantially improved using a post-hoc procedure combining prediction-value-dependent bias correction with scalar uncertainty scaling. Qualitative evaluation on a healthy volunteer showed spatially meaningful uncertainty patterns. These results indicate that diffusion model-derived uncertainty is informative for reliability assessment and selective prediction, but requires calibration for quantitative interval interpretation.

0.61

Trusting the Inverse: Reliability-Aware Mapping for Simulation-Based Microstructure Estimation in Diffusion MRI

cs.CE ·2026-09-30 ·Juan Luis Villarreal Haro, Ileana Jelescu, Jean-Philippe Thiran, Jonathan Rafael-Patino
similarity 0.49
Abstract

Diffusion-weighted MRI can probe tissue microstructure non-invasively, however interpreting microstructural parameter estimates remains challenging due to the intrinsic ambiguity of the inverse problem. While simulation-based approaches can incorporate increasingly realistic tissue models, they still lack voxel-wise characterisation of the reliability and degeneracy of the inferred parameters. Here, we introduce a reliability framework for simulation-based microstructure estimation based on three complementary scores that identify distinct sources of unreliability in the estimation process: out-of-distribution signals, local signal mismatch, and parameter degeneracy. The framework was implemented using a Monte Carlo dictionary of 1,050 synthetic voxels generated from geometrically realistic substrates, with parameter ranges grounded in electron microscopy measurements of rat corpus callosum. The dictionary spans biologically plausible axon radii (0.25-0.85 $μ$m), microscopic angular spread (0-10$^\circ$), packing densities (60-92%), and intrinsic diffusivities (1.75-3.0 $μ$m$^2$/ms). On synthetic data, the resulting Reliability Index correlated with actual estimation error (Spearman $ρ= -0.742$) and distinguished between extrapolation, poor local interpolation, and parameter degeneracy. Applied to in vivo corpus callosum DW-MRI in rat (256 voxels, four animals) and human (MGH-USC HCP, 18,765 voxels, nine subjects), 91% and 73% of voxels respectively exceeded $R > 0.5$. These results demonstrate how reliability-aware analysis can support the interpretation and future development of simulation-based diffusion MRI microstructure models.

0.20

Diffusion Posterior Sampling with Uncertain Forward Models

cs.CV ·2026-10-21 ·Wentao Shangguan, Vivek K Goyal
similarity 0.49
Abstract

Diffusion posterior samplers reconstruct signals by combining a pretrained diffusion prior with a measurement likelihood specified by a forward model and a noise model. Calibration and reference data can characterize uncertainty in the forward model's parameters, such as blur kernels or detector responses. Fixing these parameters at estimated values leaves their uncertainty out of the likelihood, and parameter errors are thus absorbed into the reconstruction. We introduce an uncertainty-aware likelihood (UAL), a Gaussian approximation to the marginal likelihood obtained by integrating over the uncertain parameters. For each candidate signal, UAL propagates parameter uncertainty into a structured measurement covariance, reducing the quadratic penalty along residual directions that parameter variation can explain. Existing samplers can use UAL in their data updates while retaining their pretrained diffusion priors and sampling schedules. Under a fixed Gaussian nuisance model, we bound likelihood error from linearization and average divergence between the exact marginal and UAL posteriors. We compare samplers with and without UAL across six inverse problems spanning Gaussian and motion deblurring, CT, MRI, ultrasound, and fluorescence microscopy, and find improvements in reconstruction and ensemble prediction. UAL reduces geometric mean MSE by 9% to 20% across samplers in the main Gaussian-deblurring setting and by 51% to 92% in motion deblurring when non-blind samplers use the population-mean kernel. In motion deblurring, DAPS and PnP-DM with UAL also give 6.2 to 6.4 dB higher ensemble-mean PSNR than published BlindDPS and Fast Diffusion EM. On the ablation set, UAL outperforms trace-matched isotropic inflation for PnP-DM in both deblurring tasks; in motion deblurring, it also exceeds the best-tested fixed scalar data weighting by 3.3 dB for PnP-DM and 4.2 dB for DAPS in average PSNR.

0.10

MUMINS: Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis

cs.CV cs.AI ·2026-09-15 ·Anna Oliveras, Roger Marí, Rafael Redondo, Oriol Guardià, Cynthia Ifeyinwa Ugwu +5 more
code/data similarity 0.49
Abstract · Supplementary material to follow in future versions

Forecasting anatomical changes such as tumor growth and neurodegeneration is a challenging generative vision task. Morphological evolution is subtle relative to static anatomy, highly patient-specific, and inherently stochastic. Existing methods struggle with several issues: deterministic networks ignore biological stochasticity, while standard diffusion models require computationally prohibitive multi-pass sampling to quantify uncertainty. We propose MUMINS (Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis), an efficient diffusion framework that jointly diffuses a baseline scan and its follow-up residual, summed to synthesize the follow-up scan, while concurrently predicting a spatial uncertainty map, in a single reverse diffusion process. Conditioned on the time interval and relevant metadata, it preserves fine-grained anatomy by dynamically re-injecting the baseline as a soft anchor at every denoising step, and a negative-log-likelihood head learns the uncertainty map to explicitly flag error-prone regions. Designed without organ-specific heuristics, the same architecture is reused across anatomies via separate, dataset-specific retraining. Extensive evaluations demonstrate that dataset-specific retraining of MUMINS matches or outperforms dedicated, domain-specific state-of-the-art methods on lung CT (PNG) and brain MRI (OASIS-3). Project page: https://aolivtous.github.io/publications/mumins.html.

0.46

Beyond Boundary Noise: Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity in 3D Lung Nodule Segmentation

cs.CV cs.LG ·2026-08-14 ·Simon Baur, Arne Schernich, Ekin Böke, Wojciech Samek, Jackie Ma
similarity 0.48
Abstract

Uncertainty estimation is critical for the safe clinical deployment of deep learning in medical image segmentation, with aleatoric uncertainty theoretically designed to capture irreducible data ambiguity. However, whether entropy-based measures reflect clinically meaningful ambiguity, i.e. case-level disagreement about whether a pathology is present at all, remains poorly understood. Contrary to most prior work, which focused on pixel-wise boundary disagreement, we systematically evaluate how well aleatoric uncertainty captures presence ambiguity. Our evaluation spans 3D lung nodule segmentation across four architectures with Monte Carlo dropout and deep ensembles, on LIDC-IDRI and an external validation cohort (LNDb). We find that entropy-based uncertainty maps align with boundary noise and minor drawing variation but carry insufficient discriminative signal for presence ambiguity. In contrast, a lightweight supervised ambiguity head trained on frozen segmentation features substantially outperforms all entropy-aggregation-based baselines across architectures, metrics, and both cohorts, and matches or exceeds methods that explicitly model ambiguity under disagreement supervision (Probabilistic U-Net, Annotator-Confusion 3D-UNet). A qualitative feature-space analysis shows that presence ambiguity is already encoded in the frozen encoder features of pixel-wise-trained networks, only to be discarded by the segmentation output and its entropy aggregation. Our findings expose a fundamental mismatch between the theoretical promise of aleatoric uncertainty and its practical behavior, and suggest that practitioners should not rely on entropy-based uncertainty as a proxy for clinical ambiguity in safety-critical applications.

0.34

A Posterior-Dynamics Framework for Imaging Inverse Problems with Pretrained Diffusion Priors

cs.AI stat.MLcs.LG ·2026-08-15 ·Zhaoqiang Liu, Tongyao Pang, Ruibing Wang, Yang Zheng
theory similarity 0.47
Abstract · 26 pages, 5 figures, 3 tables

Pretrained diffusion models represent image distributions through a continuum of progressively smoothed distributions. This multiscale structure organizes generation from global structure to fine detail and supports high-quality, diverse samples. We exploit the same multiscale diffusion prior for linear imaging inverse problems. Rather than using the pretrained model only as a denoiser in an outer iteration, we define a surrogate likelihood whose center is aligned with the clean-image coordinate and whose covariance accounts for residual diffusion uncertainty. This construction defines an explicit surrogate posterior path, from which we derive continuous posterior dynamics. A tunable Langevin component supports target tracking and allows the amount of posterior exploration to be adapted to the application. We prove endpoint consistency and a finite-horizon tracking bound and, in the exact-score setting, first-order weak accuracy. For computation, we derive the Posterior-Dynamics Implicit--Explicit sampler (PD-IMEX), a stable method using one score evaluation per diffusion scale and an implicit data-consistency update. Experiments on deblurring, super-resolution, and inpainting show strong reconstruction quality at 100 score evaluations, coarse-grid stability, and controllable fidelity--diversity behavior.

0.40

From Slices to Volumes: Comparing 2D, 2.5D, and 3D Residual Networks for Pulmonary Nodule Malignancy-Risk Classification

cs.LG cs.CV ·2026-10-25 ·Bahodir Nazarov, Zineb Gharib, Fatima Zazoul
code/data similarity 0.47
Abstract

Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate ratings. Methods: A retrospectively prepared LIDC-IDRI cohort contained 2,654 nodules labeled benign, indeterminate, or malignant using median radiologist ratings. Patient-disjoint splits comprised 1,876 training, 382 validation, and 396 test nodules. Representations included one axial slice, five neighboring slices, and a local CT volume. Each track evaluated a randomly initialized baseline, momentum-contrast pretraining followed by fine-tuning, and supervised training with mild augmentation. Checkpoints were selected by validation Macro-F1. The 2D experiments used three seeds; 2.5D and 3D results were single-run estimates. A separate binary experiment excluded indeterminate nodules. Results: Augmented models achieved test Macro-F1 values of $0.6134\pm0.0075$ for 2D, $0.6537$ for 2.5D, and $0.5403$ for 3D; the 2D uncertainty denotes population standard deviation across seeds. Corresponding accuracies were $0.6128$, $0.6869$, and $0.5455$. Augmentation improved Macro-F1 within every track, whereas the tested pretraining recipes reduced it. Binary Macro-F1 values were $0.8227$, $0.8664$, and $0.7554$, respectively. Conclusion: Augmented 2.5D achieved the highest observed performance. Differences in preprocessing, optimization, capacity, and replication limit attribution to dimensionality. Labels reflect radiologist-assessed malignancy risk rather than pathology-confirmed cancer. Code and experimental results are available at https://github.com/CT-DeepLearning-Team/CT-2D-2.5D-3D-DeepLearning.

0.18

Beyond the Evidence Boundary: Behavioral Mirage Under Progressive Degradation in Medical VLMs

cs.CV cs.CL ·2026-10-20 ·Edric Castel C. Hao, Rez Samantha Z. Floresca
published similarity 0.47
Abstract · Accepted to WMHS Workshop @ NeurIPS 2026

VLMs for medical image interpretation are typically evaluated on clean inputs, despite the progressive evidence loss that can occur in high stakes clinical settings. Existing robustness studies show that performance can degrade while confidence remains high, but do not establish when a previously reliable model-case pair ceases to behave reliably. We introduce a baseline-anchored framework that traces baseline-correct cases through progressive image degradation to identify an empirical evidence boundary, and define mirage as continued commitment at this boundary, regardless of correctness. Across three VLMs on three medical datasets, only MedGemma provides a sufficiently large baseline-correct pool for trajectory analysis. On VQA-RAD, the only dataset in which the question text varies, language-only answerability is associated with baseline correctness (AUROC 0.677) and with commitment at the boundary (AUROC 0.653 to 0.670). MedGemma's post-boundary behavior is heterogeneous, including direct mirage, correct recovery, mirage dissolution, consistent abstention, and oscillation, with mirage rates of 16.0 to 100.0% across dataset-modality pairs. Despite this behavioral heterogeneity, residual-stream probes decode commit-versus-abstain behavior at the boundary with AUROC of 0.895 to 0.994 under nested cross-validation. These results show that progressive evidence loss can produce persistent commitment that output entropy and abstention behavior do not consistently reflect, motivating boundary-aware evaluation, option-order controls, and improved abstention mechanisms for reliable medical foundation models operating under partial observation.

0.37