DER-Fault: A Simulation-Based Fault Dataset for DER-Integrated Distribution Systems Under Diverse Operating Conditions

Fathima Razeeya Mohamed Razick, Petr Musilek

eess.SP ·submitted 2026-09-28 20:41 UTC · v1

Abstract

The growth of distributed energy resource (DER) integration introduces greater variability in distribution system operating conditions, creating a need for comprehensive datasets for developing and evaluating data-driven fault diagnostic methods. This paper presents \textbf{DER-Fault}, a simulation-based dataset generated in OpenDSS using the Iowa 240-bus distribution system with photovoltaic (PV) generation, electric vehicle (EV) charging, and vehicle-to-grid (V2G) operation. To capture annual load variability while maintaining a manageable number of simulation cases, 60 representative operating conditions are selected from 8,760 hourly load profiles, covering peak, off-peak, transition, typical weekday, and typical weekend conditions. Six DER scenarios with varying PV and EV penetration levels and V2G participation are considered. The dataset includes normal operation and ten short-circuit fault classes, with varying fault resistance. Pre- and post-fault voltage and line-current phasor measurements are recorded at selected measurement locations, resulting in 19,800 simulation cases. Technical validation demonstrates broad coverage of annual loading and DER operating conditions, distinct phase-specific responses corresponding to the simulated fault types, and a consistent reduction in voltage-phasor disturbance with increasing fault resistance. The resulting dataset provides a structured resource for developing and evaluating machine-learning and other data-driven methods for fault detection, classification, and localization in DER-integrated distribution systems.

Comment
10 pages, 4 figures, Associated dataset available on Zenodo

Closest papers

Nearest neighbours by meaning across the whole index.

Equivalent Modeling of Load-Side Systems With Distributed Renewable Generation Considering Fault Responses and Nodal Voltage Coherence

eess.SY ·2026-09-21 ·Yuqi Cao, Chen Shen, Shaowei Huang, Ying Chen, Hongyi Zhu
similarity 0.62
Abstract · Submitted to IEEE Transactions on Power Systems

Operating conditions and fault severity change both the initial states and control modes of active distribution networks. Direct capacity aggregation can therefore lose the power responses required for transmission-system dynamic analysis. This paper develops a procedure for generating low-order physical electromagnetic transient equivalents from a small set of representative operating conditions. Device power, ride-through states, load mechanical states, and local sequence voltages are combined with electrical distance to form response families. Response reconstruction and terminal simulation errors determine the retained architecture, after which bounded sensitivity calculations determine effective dynamic coefficients. The architecture and coefficients are then fixed. For a new operating condition, capacity and power balances, voltage-dependent load relations, and an initialization correction generate the model parameters from static inputs and power-flow results. A representative severe fault establishes a template for each fault type, which is reused across fault depths. Aggregation and switching-time bounds explain the roles of voltage coherence and state separation. Comparisons with direct aggregation show improved terminal responses across operating conditions and several fault types, with the largest gains under severe unbalanced faults. The method provides a reusable physical equivalent for operating-condition studies and fault-depth screening.

0.17

Robust Joint Planning of EV and eBus Charging Infrastructure with PV Self-Consumption under Demand Uncertainty

eess.SY ·2026-08-19 ·Biswarup Mukherjee
benchmark similarity 0.59
Abstract · This manuscript has been submitted for peer review

This paper presents a mixed-integer linear programming (MILP) framework for joint electric vehicle (EV) and electric bus (eBus) charging-infrastructure planning with photovoltaic (PV) self-consumption. The model co-optimizes charger siting, sizing, technology selection, eBus-to-depot assignment, and hourly charging schedules. A deterministic MILP is first formulated as a nominal benchmark and then extended to a scenario-based robust min--max formulation under vehicle energy-demand uncertainty. The robust model uses shared first-stage infrastructure decisions and scenario-specific operating decisions, and minimizes infrastructure cost plus the worst-case scenario operating cost through an epigraph reformulation. Soft-feasibility penalties quantify unmet charging energy, terminal state-of-charge (SOC) shortfall, and capacity violations under stressed scenarios. A 50-node case study shows that route-segment eBus demand and PV weighting alter charger deployment, technology mix, and grid import, while V2G enables hard-feasible robust operation at sufficiently large penalty weights. These results highlight that effective long-term infrastructure planning must simultaneously account for diverse vehicle fleets, operational strategies that adapt to different scenarios, and node-level constraints on charging capacity.

0.19

Reliability Value of Long-Duration Energy Storage against Extreme Events in High-Renewable Grids: A Full-Year AC-OPF Assessment

eess.SY ·2026-09-06 ·Jeongdong Kim, Jonggeol Na, Sungho Shin
similarity 0.59
Abstract · 39 pages, 12 figures

Long-duration energy storage (LDES) can mitigate prolonged renewable--load imbalances during Dunkelflaute events, but existing studies rely on zonal or linearized DC network models and inadequately analyze the operational feasibility of the grid across a wide range of full-year renewable, load, and contingency scenarios. To address this gap, this paper introduces a multi-period alternating-current optimal power flow (AC-OPF) formulation that captures the full nonlinear network physics and assesses the reliability value of LDES in high-renewable grids. To evaluate scarcity events spanning multiple days to weeks, full-year operation is modeled as an 8,760-h load-shedding minimization over scenarios sampled from a Gaussian copula model, fitted to 2010--2025 historical wind and bus-level load data, that represents both typical variability and tail events. On a synthetic 200-bus Illinois transmission network, a hybrid fleet of battery energy storage (BESS) and LDES with 50 MW total power reduces annual load shedding by 83.0% on average relative to the base network, versus 68.5% for short-duration BESS alone at equal power. To further account for unexpected line outages throughout the year, the formulation is extended to a multi-day security-constrained AC-OPF. Under N-1contingencies, no feasible operating solution is obtained for the base network, whereas the LDES-equipped network remains feasible in all considered cases, thereby saving the cost of additional generation and transmission capacity. During the contingency period, LDES acts as a backup power supply, requiring only 5.5% more generation on average than the no-contingency base case.

0.21

A simulation based dataset of faults and events for machine learning in power systems

eess.SY ·2026-08-20 ·Georg Kordowich, Jonathan Loebel, Julian Oelhaf, Andreas Maier, Siming Bayer +2 more
similarity 0.58
Abstract

The integration of inverter-based renewable energy sources into electric grids challenges conventional power system protection. Machine learning-based solutions can address these challenges by utilizing available data in modern smart grids. However, the lack of open datasets prevents reproducibility and fair comparisons between different approaches and their results, which hinders further progress. Therefore, this paper presents EvEMTBench, a synthetic dataset of faults and events generated using electromagnetic transient simulations. The physical plausibility of the power system simulation is ensured by validating the simulation parameters against established literature and providing comprehensive documentation of the simulation procedure. The dataset is designed for training, fine-tuning, and benchmarking machine learning models by providing synchronized point-on-wave voltage and current measurements at 9600 Hz across a diverse set of topologies and voltage levels. The inclusion of a wide range of fault and operating events allows the utilization of EvEMTBench for different tasks like incipient fault detection, fault localization, or event detection.

0.50

GCN-Based Model for Fault Classification in Distribution Networks under Harmonic Distortion

eess.SP ·2026-09-23 ·Fathima Razeeya Mohamed Razick, Syed Muhammad Ahsan, Petr Musilek
published similarity 0.58
Abstract · Accepted and presented at the IEEE Power and Energy Society General Meeting 2026, Montreal, Canada, July 19-23, 2026

The increasing integration of distributed energy resources introduces new challenges for accurate fault detection and classification in distribution networks. This paper presents a topology-aware graph convolutional network-based model for fault classification under inverter-induced harmonic distortion. The model uses pre-fault and post-fault voltage and current phasors, including harmonic components, mapped to the IEEE 34-bus system topology. The simulation data generated in OpenDSS encompass varying levels of penetration of solar photovoltaics (30%, 50%, 70%) and current total harmonic distortion (0%, 1%, 3%, 5%) across multiple fault types: single line-to-ground, line-to-line, double line-to-ground, and three-phase-to-ground. A differential evolution algorithm is employed to optimize the hyperparameters of the network, resulting in a three-layer model that achieves an F1-score of 0.98. Stress testing across scenarios confirms high robustness and minimal class confusion. The results demonstrate that a graph convolutional network-based model can effectively classify distribution faults under varying photovoltaic penetration levels and harmonically distorted conditions. Comparative analyses with convolutional neural network, long short-term memory, and multi-layer perceptron architectures demonstrate that the proposed model delivers superior classification performance, particularly under the most stressed condition with 70% photovoltaic penetration and 5% harmonic distortion.

0.48

Analyzing Simultaneous Charging Factors of Electric Vehicles Using Monte Carlo Simulation: A Case Study in Phu Quoc City, Vietnam

eess.SY ·2026-11-04 ·Tien Khai Nguyen, Trong Nghia Le
published similarity 0.57
Abstract · 11 pages, 17 figures. Accepted for publication in GMSARN International Journal (expected in Issue 3, 2027). Author-prepared accepted manuscr…

This study estimates the simultaneous charging factor (SCF) of electric vehicles (EVs) in Phu Quoc City, Vietnam, using a Monte Carlo simulation. Three planning scenarios (2030, 2035, and 2040) are developed from population-based EV uptake assumptions and vehicle-specific charging probability profiles over 24 hours, reflecting distinct operating patterns of motorbikes, cars, taxis, and buses. For each vehicle class and scenario, 1,000 simulation runs are performed to compute SCF and its uncertainty, reported via 95% confidence intervals. Results indicate that SCF decreases as EV penetration increases, implying more temporally dispersed charging demand and a reduced likelihood of extreme coincidence. For electric buses, SCF declines from 0.76 (2030) to 0.59 (2040), and other vehicle groups show similarly decreasing trends across the horizon. These SCF estimates provide practical inputs for grid-aware charging infrastructure planning, including diversity factors for sizing distribution transformers and feeders, identifying peak-hour stress, and informing demand management measures such as time of use tariffs and basic smart charging controls.

0.68

A High-Resolution Synthetic EV Charging Dataset for Cold-Climate Distribution Grid Impact Analysis: Trondheim, Norway (2020-2030)

eess.SY ·2026-08-31 ·Hanieh Taraghi Nazloo, Petr Musilek
benchmark similarity 0.56
Abstract · 10 pages, 4 figures, 2 tables. Dataset available on Zenodo: DOI 10.5281/zenodo.22132618

This data article presents a high-resolution, long-term synthetic electric-vehicle (EV) charging dataset for Trondheim, Norway, spanning February 2020 to December 2030. Empirically grounded in 14 months of historical charging logs from December 2018 to January 2020, the dataset captures session-level behavioral patterns, including delivered energy, plug-in duration, connection schedules, user categorization (private vs. shared), seasonal variations, public-holiday effects, and daily ambient temperature dependencies. To model future electrification dynamics, the synthetic generation pipeline integrates historical session records, calendar and weather features from MET Norway, annual EV-adoption growth multipliers derived from Statistics Norway (SSB) registration trajectories, a daily session-count model, a Conditional Tabular Generative Adversarial Network (CTGAN), seasonal Kernel Density Estimation (KDE), and post-generation physical charger-power feasibility correction. Under a standardized 7.2 kW AC charging constraint, the resulting medium EV-adoption scenario dataset contains 76,993 hourly charging-activity records. The hourly profile is activity-based rather than a complete continuous hourly time series; hours with no allocated EV charging energy are not included. The records provide total hourly charging energy, equivalent average charging power, active session counts, private/shared user load breakdowns, ambient temperature features, and calendar indicators. The dataset provides a validated cold-climate benchmark for distribution-grid impact assessment, transformer-loading analysis, EV charging-demand forecasting, charger-capacity planning, energy-management optimization, and the development of data-driven smart-charging control strategies.

0.18

A Benchmark Graph Dataset for Transient Stability Assessment of the IEEE 9-Bus System: 20,000 Scenarios with Full Generator Trajectories

eess.SY ·2026-08-18 ·Hussein Suprême, Martin de Montigny, Arnaud Zinflou
publishedbenchmark similarity 0.56
Abstract · Descriptor Open dataset IEEE9

Transient stability assessment determines whether a power system retains synchronism after a large disturbance. Machine-learning surrogates can accelerate it, but progress is limited by the lack of open datasets that combine dynamic ground truth, network graph structure, and machine parameters. We release a benchmark of 20,000 three-phase-to-ground fault scenarios on the IEEE 9-bus system. Each scenario couples an AC power-flow operating point with a detailed electromagnetic-transient simulation of the post-fault response. Every record provides the network as an attributed graph (nine buses, eighteen directed branches, ten node and twelve edge features), the full rotor-angle and speed trajectories of the three generators, the static machine constants, the fault description, and a center-of-inertia binary stability label. Wide load and generation scalings across eighteen fault locations yield a near-balanced distribution (48.96\% stable, 51.04\% unstable). Generation is deterministic and fully reproducible through fixed seeds and public code. The dataset is distributed on IEEE DataPort under a persistent DOI and supports stability classification, trajectory prediction, margin and critical-clearing-time estimation, and the comparison of topology-aware, physics-based, and hybrid learning methods.

0.43