CS Paper Radar

Preserving Anatomical Continuity: Three-Stage Pipeline for Colon Segmentation in 3D Abdominal CT Scans

Deshan Kalupahana, Sonit Singh, Praveen Ravindran, Arcot Sowmya

cs.CV cs.AI ·submitted 2026-10-02 15:41 UTC · v1
published

Abstract

Accurate colon segmentation from CT images is essential for colorectal disease analysis, yet deep learning based methods often produce disconnected predictions due to complex anatomy. This study introduces a three-stage, topology-preserving segmentation pipeline to address this issue. The first stage performs initial deep learning-based segmentation, followed by centreline bridging to reconnect disjoint regions and a reconstruction stage to refine continuity. Evaluations on TotalSegmentator and RAOS datasets using overlap, distance and topology-based metrics demonstrate improved structural consistency while maintaining segmentation accuracy. The proposed method enhances topological integrity, enabling more reliable colon segmentation for clinical and research applications.

Comment
5 pages, 2 figures
Journal ref
IEEE 23rd International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2026
DOI
10.1109/ISBI61048.2026.11515927

Closest papers

Nearest neighbours by meaning across the whole index.

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.65
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

Colorectal Cancer Segmentation with Adaptive Augmentation and Multi-Resolution Ensemble Models

eess.IV cs.AIcs.CV ·2026-09-29 ·Ümit Mert Çağlar, Alptekin Temizel
publishedcode/data similarity 0.65
Abstract · SPIE Eighteenth International Conference on Machine Vision (ICMV 2025), Paris, France

Colorectal cancer (CRC) is the second most deadly and third most common cancer, and the leading cause of death among gastrointestinal cancers. Early diagnosis is crucial for the treatment of this cancer and increasing the survival rates. Although CRC is more common in developed regions, its occurrence is also increasing in developing regions as well. CRC diagnosis relies on histopathology assessment post-biopsy. Automated deep learning algorithms can significantly reduce diagnosis time, enhancing efficiency and supporting timely clinical decisions. We present an automated segmentation pipeline for whole-slide histopathology images that labels tumor grades 1-3 and normal mucosa. It utilizes dense prediction transformers with various encoder backbones, overlapping patches, and test-time augmentation. An adaptive augmentation policy, guided by large language models, further improves training. Top models were ensembled via soft voting, and mask refining post-processing steps, Gaussian blurring, morphological closing, and connected components analysis. On a colorectal cancer grade dataset, our method improved the F1 score from 62.92 to 69.84. Code is available here: github.com/caglarmert/ICIP2025

0.34

Lesion-centered 3D mapping of colonoscopy procedures: validation of a hierarchical ensemble pipeline on public benchmark videos

cs.CV ·2026-09-15 ·Hyunjun Kim, Hyeonwoo Na, Jaewoo Lee
benchmarkcode/data similarity 0.64
Abstract · 21 pages, 12 figures, 4 tables. Code: github.com/hyunjun1121/endovision-pipeline (Zenodo DOI 10.5281/zenodo.22136766)

Background and Objective: Colonoscopy recording practice preserves text reports and still photographs, while the spatial information already present in the recorded video - where the scope traveled, where a lesion was observed, and whether the same lesion was seen again - is discarded when the procedure ends. This study determines whether a lesion-centered spatial record can be assembled and validated without full-colon 3D reconstruction. Methods: A four-layer hierarchical pipeline was assembled - (1) a global topological map, (2) lesion-level spatio-temporal tracks, (3) on-demand local 3D reconstruction, and (4) persistent lesion identity across repeated observations - and ran end to end on four public videos (two C3VDv2 sequences with ground-truth depth and two full REAL-Colon procedures; 40,245 frames). All components are published, individually validated methods; the contribution is their lesion-centered assembly, linking rules, and evaluation. Results: Revisits, impossible under forward-only mapping by construction, were detected by entry-map Bayesian localization: 5,614 and 4,043 revisit events (56 and 68 distinct nodes) in the two full procedures. Lesion-identity merging at the adopted threshold 0.5 maintained ground-truth purity 1.0 while auto-merging 20 of 231 candidate pairs. The endoscopy-specific geometry engine outperformed a general-purpose foundation model on all metrics (overall absolute relative error (AbsRel) 0.2276 vs. 0.3523). Conclusions: The results are partial but establish a concrete near-term path: revisit detection, lesion identity, and local 3D each returned quantitative, reproducible output without waiting for complete geometric reconstruction; validating the record on clinical data is the next step.

0.52

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.62
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

CSG-Mamba: A Convolutional Scoring Gating Vision State Space Network for Endoscopic Polyp Segmentation

cs.CV ·2026-08-14 ·Yuliang Wang, Jiaqi Wu, Jiaye Song, Shuxia Ren
published similarity 0.62
Abstract · 14 pages, 6 figures, and 5 tables. Accepted by ICONIP 2026

Accurate polyp segmentation is critical for computer-aided colonoscopy, yet endoscopic images often contain low-contrast boundaries, mucosal texture interference, specular highlights, and device-dependent appearance shifts. Vision State Space Models (SSMs) provide efficient long-range modeling with linear complexity, but existing Vision Mamba segmentation models typically convert 2D features into 1D scanning sequences, which may weaken local geometric continuity and over-smooth irregular contours. We propose CSG-Mamba, a convolutional scoring gating Vision State Space network for endoscopic polyp segmentation. Built on a VM-UNet-style asymmetric U-shaped encoder-decoder, CSG-Mamba inserts a Convolutional Scoring Gating (CSG) module at the semantically rich bottleneck. CSG generates a local spatial score map through pointwise and large-kernel depthwise convolutions and recalibrates state-space features by multiplicative gating. Experiments with three random seeds show that CSG-Mamba achieves 0.9220 Dice and 15.87 HD95 on Kvasir-SEG, and 0.7418 Dice and 0.6570 mIoU on CVC-ColonDB, outperforming the baselines on most overlap and recall metrics while maintaining competitive boundary accuracy.

0.28

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published similarity 0.62
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40

Anatomical Prior-Guided Routing for 3D Lung Tumor Segmentation

cs.CV ·2026-10-29 ·Uihyeon Maeng, Jonghun Kim, Hyunjin Park
published similarity 0.62
Abstract · Accepted to ACCV 2026 (Oral), 18 pages, 6 figures

Accurate lung tumor segmentation in computed tomography (CT) is essential for treatment planning, response assessment, and quantitative imaging analysis. However, 3D lung tumor segmentation remains challenging because tumors occupy only a small portion of the whole volume and exhibit heterogeneous appearances across anatomical locations. In patch-based training and sliding-window inference for 3D medical image segmentation, location-dependent heterogeneity is further amplified because cropped image patches provide limited global anatomical context, making it difficult for a model to adapt its feature processing according to the anatomical region from which each patch is extracted. To address this limitation, we propose an Anatomical Prior-guided Routing Module (APRM) for lung tumor segmentation. For each image patch, we obtain anatomical prior information of regional occupancy and deterministically select an anatomical routing gate. The selected gate then performs sparse feature routing over a shared expert adapter pool, enabling anatomy-specific feature adaptation while sharing expert capacity across regions. We evaluate APRM on two datasets with various backbone networks and demonstrate consistent improvements over baseline models. Furthermore, feature visualizations show that APRM produces different feature responses depending on patch location, indicating that the proposed routing mechanism effectively adapts feature processing according to anatomical context.

0.26

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.62
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16