CS Paper Radar

Lesion-centered 3D mapping of colonoscopy procedures: validation of a hierarchical ensemble pipeline on public benchmark videos

Hyunjun Kim, Hyeonwoo Na, Jaewoo Lee

cs.CV ·submitted 2026-09-15 05:54 UTC · v1
benchmarkcode/data

Abstract

Background and Objective: Colonoscopy recording practice preserves text reports and still photographs, while the spatial information already present in the recorded video - where the scope traveled, where a lesion was observed, and whether the same lesion was seen again - is discarded when the procedure ends. This study determines whether a lesion-centered spatial record can be assembled and validated without full-colon 3D reconstruction. Methods: A four-layer hierarchical pipeline was assembled - (1) a global topological map, (2) lesion-level spatio-temporal tracks, (3) on-demand local 3D reconstruction, and (4) persistent lesion identity across repeated observations - and ran end to end on four public videos (two C3VDv2 sequences with ground-truth depth and two full REAL-Colon procedures; 40,245 frames). All components are published, individually validated methods; the contribution is their lesion-centered assembly, linking rules, and evaluation. Results: Revisits, impossible under forward-only mapping by construction, were detected by entry-map Bayesian localization: 5,614 and 4,043 revisit events (56 and 68 distinct nodes) in the two full procedures. Lesion-identity merging at the adopted threshold 0.5 maintained ground-truth purity 1.0 while auto-merging 20 of 231 candidate pairs. The endoscopy-specific geometry engine outperformed a general-purpose foundation model on all metrics (overall absolute relative error (AbsRel) 0.2276 vs. 0.3523). Conclusions: The results are partial but establish a concrete near-term path: revisit detection, lesion identity, and local 3D each returned quantitative, reproducible output without waiting for complete geometric reconstruction; validating the record on clinical data is the next step.

Comment
21 pages, 12 figures, 4 tables. Code: github.com/hyunjun1121/endovision-pipeline (Zenodo DOI 10.5281/zenodo.22136766)

Closest papers

Nearest neighbours by meaning across the whole index.

Colon3R: Cross-Domain 3D Reconstruction from Monocular Colonoscopic Video

cs.CV cs.RO ·2026-09-21 ·Zhihao Xing, Yingyu Wang, Liang Zhao, Shoudong Huang
code/data similarity 0.65
Abstract

Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflections, limited view overlap, and non-rigid tissue motion. Conventional multi-view 3D reconstruction methods rely on stable correspondences and approximate rigidity, which are often violated in colonoscopy. Existing endoscopic methods often rely on domain-specific supervision, whereas there are not enough in-vivo labeled data available to adapt geometry foundation models to clinical colonoscopy. We present Colon3R, a cross-domain semi-supervised framework built on pretrained VGGT that transfers coupled camera, depth, and pointmap geometry from labeled phantom and simulated data to unlabeled in-vivo colonoscopy without requiring target-domain geometric annotations. Unlike source-only fine-tuning, which learns only from phantom and simulated data, Colon3R directly exploits unlabeled in-vivo video through teacher-derived cross-view supervision. Our proposed hierarchical quasi-rigid reliability selects reliable supervision at the sequence, directed-pair, and pixel levels, while source-preserving adaptation retains the learned coupled geometry during target-domain adaptation. Extensive experiments demonstrate that our method achieves superior overall performance over state-of-the-art approaches in depth, pointmap, and camera pose estimation. Qualitative comparisons on real in-vivo colonoscopy further show substantially more complete and geometrically consistent reconstructions than competing methods under clinical domain shift. The code is publicly available at https://github.com/vglx/Colon3R.

0.29

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.64
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21

TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection

eess.IV cs.CVcs.LG ·2026-08-13 ·Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen +1 more
publishedcode/data similarity 0.64
Abstract · Accepted to EndoLINA @ MICCAI 2026 (The International Workshop on Endoluminal Intervention Navigation and Autonomy)

Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at https://github.com/sdoerrich97/true-colon.

0.38

Preserving Anatomical Continuity: Three-Stage Pipeline for Colon Segmentation in 3D Abdominal CT Scans

cs.CV cs.AI ·2026-10-02 ·Deshan Kalupahana, Sonit Singh, Praveen Ravindran, Arcot Sowmya
published similarity 0.64
Abstract · 5 pages, 2 figures

Accurate colon segmentation from CT images is essential for colorectal disease analysis, yet deep learning based methods often produce disconnected predictions due to complex anatomy. This study introduces a three-stage, topology-preserving segmentation pipeline to address this issue. The first stage performs initial deep learning-based segmentation, followed by centreline bridging to reconnect disjoint regions and a reconstruction stage to refine continuity. Evaluations on TotalSegmentator and RAOS datasets using overlap, distance and topology-based metrics demonstrate improved structural consistency while maintaining segmentation accuracy. The proposed method enhances topological integrity, enabling more reliable colon segmentation for clinical and research applications.

0.38

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

eess.IV cs.AI ·2026-11-17 ·Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey +4 more
benchmark similarity 0.60
Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

0.12

KFS$^4$LAM: Adaptive KeyFrame Selection with Structure-Aware Mapping for Endoscopic Gaussian Splatting SLAM

cs.CV ·2026-10-15 ·Xinwei Ju, Zhehua Mao, Tianyi Song, Danail Stoyanov, Sophia Bano +1 more
code/data similarity 0.59
Abstract · 8 pages, 5 figures, 3 tables

Gaussian-splatting Simultaneous Localization and Mapping (SLAM) augments conventional SLAM with a dense, renderable 3D scene representation, enabling high-quality reconstruction and novel-view synthesis. However, its localization, reconstruction, and rendering performance depends strongly on which observations are retained for mapping. Existing systems commonly rely on fixed temporal intervals or simple pose- and overlap-based criteria for keyframe selection. In colonoscopy, non-uniform camera motion, repetitive anatomy, specularities, and visual artifacts can make these criteria unreliable, leading to either redundant keyframes or missed informative viewpoints. We present KFS$^4$LAM (KeyFrame Selection with Structure-aware mapping for endoscopic Gaussian Splatting SLAM), which couples motion-guided adaptive keyframe selection with structurally supervised mapping and restricted temporal deformation. Accumulated motion guides adaptive keyframe selection, with complementary cues suppressing redundant or unreliable candidates. Density-aware mapping with anatomical contour supervision (colon folds) emphasizes structurally informative regions, while restricted temporal deformation accommodates local tissue dynamics without unconstrained geometric drift. We evaluate KFS$^4$LAM against Gaussian-SLAM baselines on C3VD and C3VD-v2, together with cross-backbone and component ablations. KFS$^4$LAM achieves strong overall performance across trajectory, rendering, and depth metrics, with pronounced gains on more challenging C3VD-v2 dataset. In the matched comparison with SplaTAM on C3VD-v2, it reduces rotational relative pose error by 20.3% and depth RMSE by 38.4%, while improving PSNR by 0.78 dB. Cross-backbone experiments further show that the framework is not tied to a single underlying SLAM architecture. Code and visualization results are available at https://xinweiju.github.io/KFSLAM/.

0.26

On the Robustness of Temporal Vision-Language Models for Surgical Endoscopy Videos

cs.CV ·2026-08-14 ·Darakshan Rashid, Raza Imam, Ufaq Khan, Muhammad Bilal, Shazad Ashraf +7 more
top venuebenchmark similarity 0.59
Abstract · Accepted to MICCAI 2026

Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.

0.29

Object-Centered Reconstruction for Vision-Based 3D Force Estimation

cs.RO ·2026-09-20 ·Zhonghao Zhang, Mingyeung Wu, Hao Yang, Ayberk Acar, Alan Kuntz +1 more
similarity 0.57
Abstract

Excessive force may damage tissue and increase the risk of anastomotic leakage in robotic colorectal surgery. Although the da Vinci 5 provides force sensing, this capability is unavailable on earlier da Vinci systems and many other surgical robotic platforms. In this work, we present a vision-based pipeline for estimating 3D interaction forces from soft-tissue deformation in stereo endoscopic video. We dynamically reconstruct the tissue point cloud in an object-centered coordinate frame, track tissue points with geometric constraints, and predict the 3D force vector with a neural network. We progressively evaluate the pipeline on rubber-glove phantoms, ex vivo porcine colons, and in vivo colorectal surgical video sequences. Under varying tissue orientations and positions within the endoscopic view, as well as different camera viewpoints, the proposed method achieves average root mean square error (RMSEs) of 0.77 N and 1.30 N on the phantom and porcine colon, respectively. Compared with the camera-frame representation, the object-centered representation reduces average RMSE by 51.3% and 56.7%, while geometry-constrained tracking reduces RMSE by 19.8% and 25.3% compared with CoTracker. We further qualitatively demonstrate the feasibility of vision-based force estimation on an in vivo colorectal surgical sequence, as a step toward clinical translation of vision-based, sensorless force estimation.

0.18