CS Paper Radar

Consumer empowerment: need, definition, quantification, outcomes and challenges

Md Umar Hashmi

eess.SY ·submitted 2026-10-04 02:26 UTC · v1

Abstract

The transition toward decentralized digitalized and lowcarbon electricity systems is fundamentally changing the role of electricity consumers Traditionally passive endusers are increasingly expected to integrate distributed energy resources DERs and participate in energy management and demand response This paper examines consumer empowerment CE in electricity networks with a specific focus on small consumers connected to distribution networks The paper first discusses the technical economic and societal drivers underlying the growing need for CE including increasing DER penetration electrification of heating and transportation network congestion and flexibility requirements A comprehensive definition of CE is then proposed based on six elements active participation enhanced choice information and control automation and controllability selfsufficiency and resilience and energy communities with shared ownership The proposed CE definition is an explicit consideration of weakgrid where security of supply is not guaranteed To support consistent assessment across different electricity systems a framework for quantifying CE is developed based on the availability of technology and policy enablers and consumers ability to ensure security of supply The paper further reviews global experiences and implementation practices across different continents highlighting variations in technological readiness regulatory support and securityofsupply considerations Finally the expected outcomes and challenges of CE are discussed The expected outcomes of CE are improving affordability flexibility resilience market efficiency DER integration and decarbonization while its successful implementation requires overcoming barriers related to information access digital literacy affordability regulation interoperability privacy cybersecurity and consumer engagement

Closest papers

Nearest neighbours by meaning across the whole index.

Technical Report on Resilient and Secure Large-Scale Energy Internet Systems

eess.SY cs.CR ·2026-08-13 ·Ioannis Zografopoulos, Karen Largman, Isaac Ortega Romero, S M Zia Ur Rashid, Yexiang Chen +9 more
similarity 0.54
Abstract · Task Force on Resilient and Secure Large-Scale Energy Internet Systems, August 2026

This IEEE PES Task Force report examines the security and resilience of large-scale Energy Internet (EI) systems, in which electricity, information, and market layers are tightly coupled through pervasive digitalization. The report characterizes the EI cyber-physical threat landscape and surveys detection, assurance, and mitigation techniques, presents modeling, control, and decision-making frameworks that capture cyber-physical interdependencies, including storage integration, multi-dimensional resilience, and electricity price forecasting, examines adversarial risks and trustworthy deployment of artificial intelligence, and introduces graph-based, attack-resilient information routing. The report closes with recommendations for research, standardization, and regulatory efforts needed to realize a resilient and secure large-scale EI.

0.04

From functioning to evolving: A complex systems perspective on future self-organised federated energy communities

cs.CE eess.SY ·2026-09-21 ·Abdorasoul Ghasemi
position similarity 0.53
Abstract · 15 pages, 2 figures, 4 tables

Energy networks face a paradigm shift driven by renewable integration, uncertainty about required flexibility, distributed markets, and smart demand. Increasing asset interactions, cyber dependencies on communication and computation systems, and the deployment of AI agents demand a holistic, system-wide approach to understand the system's emergent behaviour. These transformations affect energy generation, demand adaptation, grid operations, and market dynamics, forming a complex engineered \emph{system of systems}. We argue that a complex-systems perspective can help to understand this evolution. Drawing lessons from two highly successful large-scale engineered systems, the Internet and agile software engineering, we highlight how prioritising design for evolution over traditional design for functionality enables energy systems to adapt to net-zero dynamics and handle unforeseen uncertainties. We discuss how the notion of federated energy communities (FEC), which aims for an open energy system with distributed coordination, aligns with this perspective. In FECs, each EC produces, stores, and manages its own energy, enabling it to trade with peers, respect grid constraints, and reach fair agreements. Beyond regulatory issues, the main challenge is identifying constraints that can orchestrate EC operations at the scale and reliability standards required of power networks, without unnecessarily limiting the innovation needed for system evolution. We then conclude with tentative design principles for future decentralised, self-organised energy networks through the lens of design for evolution, and how to apply them to a bottom-up architecture of autonomous energy communities.

0.19

Comparative Analysis of Large Load Interconnection Requirements Across U.S. Transmission Entities

cs.AR ·2026-10-27 ·Rafi Zahedi, Rahul Anilkumar, Amin Zamani
publishedbenchmark similarity 0.52
Abstract

The rapid growth of large loads, especially data centers driven by artificial intelligence, is creating unprecedented demands on the North American electric grid. Data centers now account for nearly 80% of large load interconnection requests in the Western Interconnection, and U.S. electricity consumption from data centers is projected to reach 325-580 TWh by 2028. Despite this urgency, technical interconnection requirements for large loads have not yet matured and still contain several gaps. This paper presents a comparative analysis of large load interconnection requirements across eleven U.S. entities, including AEP, Ameren, CAISO, Dominion, Duke Energy, ERCOT, LIPA, MISO, PJM, Southern Company, and SPP, under seven technical categories: large load definition, load data and modeling, fault ride-through, load curtailment and shedding, dispatchability, power quality, and reactive power control. The analysis reveals significant variation in both the scope and specificity of requirements. LIPA addresses all seven technical categories at least partially, while Dominion and Duke Energy provide detailed coverage across nearly all categories. The analysis also finds that data center applicants can be viewed as potential grid resources, rather than only as consumers. The findings provide a structured baseline from which utilities, regulators, ISOs/RTOs, and developers can identify gaps, benchmark against peers, and accelerate the development of interconnection standards.

0.33

A Critical Review of Grid Integration Challenges and Flexibility Opportunities for Large-Scale Data Centers

eess.SY ·2026-10-14 ·Bibek Dhakal, Manohar Chamana, Biswambhar Gayen, Jatendar Kumar, S M Shams Rahman +5 more
similarity 0.52
Abstract

The rapid proliferation of cloud computing and artificial intelligence workloads is fundamentally reshaping the magnitude, spatial concentration, and electrical characteristics of data center power demand. Data centers differ from conventional commercial loads because they combine high rack densities, converter-dominated interfaces, thermally coupled cooling, uninterruptible power supplies, programmable workloads, and increasingly complex behind-the-meter generation and storage within a single facility. This review examines their grid integration from utility and sustainable-energy perspectives across resource planning, large-load interconnection, distribution feeders, market operation, real-time dynamics, power quality, and asset management. Particular attention is given to distribution-level issues that receive limited treatment in broader energy reviews: bidirectional operation on renewable-rich feeders, harmonic propagation and resonance, ride-through and reconnection, transformer derating, cable ampacity, neutral-conductor heating, protection, and measurement. Static, composite, physics-based dynamic, calibrated, impedance, electromagnetic transient, and hybrid load models are compared according to study purpose and data requirements, and utility coordination platforms, uninterruptible power supply and battery control, workload flexibility, renewable co-location, cogeneration, fuel cells, thermal storage, and clean firm supply are assessed. The central finding is that requested peak demand and annual energy matching alone cannot establish reliable or sustainable integration. Credible assessment must consider hourly and locational supply, network deliverability, marginal emissions, lifecycle and water impacts, backup obligations, rebound, asset health, and verified operating capability.

0.12

Feeder-Aware Service-Conditioned Flexibility of Grid-Interactive Buildings

eess.SY ·2026-10-22 ·Dafang Zhao, Ittetsu Taniguchi, Takao Onoye
similarity 0.52
Abstract

Grid-interactive buildings can adjust demand, but building-feasible power budgets may differ from accepted feeder-head offers. This study addresses a practical question: to what extent can the adjustable electricity consumption of buildings be translated into deliverable flexibility services while satisfying feeder-head operating requirements? To enable a fair comparison, we adopt the same baseline operating schedule, equipment conditions, and post-service recovery requirements for indoor temperature and battery state of charge (SOC). Flexibility is then evaluated under two settings: one considering only building-level constraints, and the other additionally accounting for feeder-head constraints. We first use a simplified network model with explicit security margins to determine a preliminary amount of flexibility that can be committed. The resulting schedule is then validated using a more detailed network simulation via Modelica. If network losses cause the actual response to deviate from the committed response, the electricity consumption of individual buildings is rescheduled. If the required response still cannot be achieved, the committed flexibility level is reduced. The experiments cover multiple service activation times, regulation directions, and service durations. For comparative purposes, we retain the initial optimization result as the reference estimate of the maximum potentially available flexibility, rather than interpreting the failure of a particular subsequent realization attempt as evidence that a larger flexibility level is inherently infeasible. The results demonstrated that 24.51\% of nonzero flexibility contracts were rejected due to feeder-head constraints, 67.04\% of contracts were accepted with some rescheduling and building redispatch, and only 8.09\% of contracts were accepted without any changes.

0.16

Assessment of the N-1 voltage security of a future Nordic energy system

eess.SY ·2026-09-21 ·Luis Kuhrmann, Peiyuan Chen, Lisa Göransson, Filip Johnsson
similarity 0.52
Abstract · 17 pages, 13 figures. Submitted to the International Journal of Electrical Power and Energy Systems

Capacity Expansion - Energy System Models (CE-ESMs) have been widely used to optimize the decarbonization of future energy systems on national and continental scales. To capture the limitations in electricity trade between different parts of the system investigated, CE-ESMs often include a representation of the transmission grid. However, CE-ESMs usually only include linearized representations of the grid and omit or strongly simplify grid stability requirements. In this work, we evaluate the N-1 voltage security of the electricity system results obtained from a CE-ESM of a decarbonized Nordic energy system in Year 2050, and analyze the effects of different grid code requirements and shunt capacitor and reactor automation on voltage security. For comparison, we evaluate a Year 2022 system based on ENTSO-E data.We show that the CE-ESM results for the Nordic countries are not N-1 voltage-secure and that, depending on the grid code and shunt automation requirements, the contingencies with voltage violations range from 1.1% to 17.4%. Furthermore, the results indicate that both Power Park Module voltage control and shunt extreme voltage automation have strong positive effects on voltage security in the modeled future system. Grid regions with low levels generation, and thus little dynamic reactive power from generators, are found to be the most at risk of being voltage-insecure.

0.29

Residential Vehicle-to-Grid Deployment: A United States-Based Stakeholder Perspective

eess.SY ·2026-11-05 ·Nelson Nelson, Nora Agah, Kasey M. Faust, Javad Mohammadi
similarity 0.51
Abstract

The integration of vehicle-to-grid (V2G), in which electric vehicle (EV) owners can send electricity from their vehicles back to the grid, is an emerging solution to enhance grid resilience. However, V2G deployment in the United States lags behind many other countries. This can be attributed to a broad range of factors, and to investigate them, this study analyzes semi-structured interviews with stakeholders using inductive-deductive qualitative coding. Results from the interviews are coded across financial, technical, social, political, and organizational dimensions in order to understand the three main deployment factors of drivers, benefits, and barriers of V2G. Once coded, the relationships between these factors are used to construct a cognitive map to identify actions that will most effectively drive V2G deployment. The results indicate that grid resilience and decarbonization are seen as the main benefits of V2G. User willingness to participate, a lack of technological readiness and standardization, prohibitive costs, and unsupportive laws and policies are among the most frequently cited barriers. Connections in the cognitive map indicate that the most closely related drivers for mitigating these barriers are user compensation for battery degradation, community outreach, the creation of grid interconnection standards and protocols, and supportive grants and policy frameworks for V2G piloting and adoption.

0.32

Shift or curtail? How much data-center flexibility is worth depends on the host power grid

eess.SY physics.soc-ph ·2026-08-20 ·Saroj Khanal, Geon Roh, Boyu Yao, Abraham Silverman, Dennice Gayme +3 more
similarity 0.49
Abstract · Submitted to Nature Energy

Data-center growth risks overbuilding power grid infrastructure and stranding capital. Flexible data-center operation can defer infrastructure investments, but its value depends on the flexibility mechanism and the host power grid characteristics. We classify data-center load as firm, flexible or interruptible, and embed them in capacity expansion applied to market-organized, fossil-heavy PJM and carbon-capped, centrally coordinated Korea. In PJM, the flexibility value is spatial: shifting workloads between zones reduces system cost by 6% in 2028 and 19% in 2038, avoiding 4.4 GW and 8.9 GW of gas and nuclear generation. In Korea, it is temporal: shifting load into midday solar hours makes 0.5 GW of additional solar worth building in 2028 and avoids 1.2 GW of gas and 0.3 GW of batteries in 2038. In both, realistic event-shape limits diminish the value of curtailment. The results show that flexibility procurement and its value are driven by grid characteristics and policy objectives.

0.46