CS Paper Radar

Conditional Rank Allocation for Taxonomy-Aware Medical Language Model Adaptation

Guangyuan Dong, Ziwei Hong, Xuehao Zhou, Zidong Yu, Bingchen Liu, Kehan Liu, Chuang Liu, Rong Fu, Yuchao Hou

cs.AI ·submitted 2026-10-05 17:38 UTC · v1
published

Abstract

Medical question answering spans specialties and clinical operations that may benefit from different adaptation directions. We propose ARBOR, a parameter-efficient method that selects rank-one components from a shared low-rank basis for each question. An additive gate combines question representations, specialty tags, operation tags, and their interaction; a learned coefficient scales the adapter residual. An illustrative separation under orthogonal, equiprobable subtasks shows how conditional selection can avoid an approximation floor faced by a fixed update with the same active rank. This result motivates the design without asserting a corresponding bound for medical corpora. On Qwen3-8B across CMB, CMExam, MedQA, and MedMCQA, five-seed experiments yield 69.69% mean accuracy across benchmarks, exceeding LoRA r16 and MoELoRA by 1.26 and 1.30 percentage points, respectively. The reported advantage over LoRA r16 increases from 0.08 to 1.94 points as training expands from one to seven specialties. Tag perturbations and atom masking support the usefulness of clinical routing, while atom clusters align with the supplied specialty labels (adjusted Rand index 0.62). Calibration, transfer, and measured costs further characterize the method. These findings support structured conditional adaptation for medical QA, while leaving clinical safety and broader deployment untested.

Comment
Accepted at IEEE BIBM 2026

Closest papers

Nearest neighbours by meaning across the whole index.

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.71
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26

Clinician use of language models diverges from how the models are evaluated

cs.CL ·2026-10-08 ·Krithik Vishwanath, Haitong Lin, Anton Alyakin, Jin Vivian Lee, D. Brock Hewitt +17 more
benchmark similarity 0.65
Abstract

Large language model (LLM) assistants are being deployed to clinicians across health systems, and judgments about their readiness rest largely on benchmark scores, most of them derived from examination questions or curated cases. A benchmark predicts performance in deployment only to the extent that its items resemble real use, yet whether benchmarks reflect the work these systems receive has rarely been measured. Here we analyze 127,833 queries sent by 6,342 physicians, advanced practice providers and nurses in 35 specialties to an institutional assistant during an eight-month roll-out. We characterize each query with RCQ-Map, a clinician-validated framework grounded in taxonomies of clinical questions and of LLM evaluation, which records its task, intent, answerability, missing information and potential harm. Documentation and administration (36.2%) and knowledge retrieval (28.9%) made up nearly two-thirds of use, and diagnosis 3.7%; more than a third of queries could not be answered well as posed. Applying RCQ-Map to 58 public benchmarks drawn from major evaluation suites and frontier model reports, which we assemble into the Clinical AI Benchmark Atlas, showed that the median benchmark contained no documentation requests and shared 31% of the task mix of real use, less than an even spread across task categories would. Benchmarks in suites designed to resemble clinical practice were individually no closer to real use than those used in frontier model reports. Benchmark scores therefore say little about how clinical AI performs on most of the work it is actually given, and evaluation should be matched to real clinical use.

0.08

Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA

cs.CL cs.LG ·2026-09-01 ·Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
top venuebenchmarkcode/data similarity 0.65
Abstract · Accepted to EMNLP 2026 (Main Conference). 9 pages, 4 figures (main text); 28 pages total, including appendix. Code and data: https://github.…

Linear classifiers trained on hidden states of a large language model (LLM), linear probes, can flag factual errors from a single forward pass. Geometrically, that implies that true and false statements separate along a stable direction in hidden state space, i.e., the truth direction. Prior work disagrees on whether this generalises across input shifts, but the disagreement is hard to interpret because cross-dataset probe transfer experiments confound several kinds of input change at once. We isolate three such variables in medical question-answering (QA): writing style (register), domain (medical specialty), and corpus (dataset). We build a benchmark using 500 MedQA entries, each rewritten into four styles (textbook, patient, clinical note, colloquial), annotated with clinical specialty, and grouped with two other exam corpora, MedMCQA and MMLU-medical, for cross-dataset evaluation. Probing four open-weight LLMs (2--8B), we find that the truth direction is largely robust to writing style (mean $Δ_\text{register} \approx 0.10$ AUROC on held-out facts) and to medical specialty ($Δ_\text{specialty} \approx 0.03$), but degrades unevenly across corpora: by $0.12$ AUROC on MMLU-medical and by $0.21$ on MedMCQA, roughly twice the register gap. The register result replicates with a second generator and carries over to human-written patient questions. The truth direction is therefore largely stable within the medical domain but breaks under some corpus shifts, and question format does not explain the break, which suggests that the signal a linear probe recovers is partly bound to dataset structure rather than to medical knowledge alone.

0.60

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.65
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.09

Ontology Concept Overlap as a Training Signal: Knowledge-Grounded Reinforcement Learning for Clinical Question Answering

cs.CL cs.LG ·2026-10-05 ·Aditya Tanna, Abhishek Jindal
top venue similarity 0.65
Abstract · Accepted at CIKM 2026

Reinforcement learning post-training for language models relies on two reward designs: human preferences (RLHF, DPO) and binary verifiers (RLVR). Clinical question answering fits neither. Near-correct answers differ by a single substituted entity, and no executable check decides clinical correctness. We instantiate a soft verifier from a maintained controlled vocabulary: UMLS Concept Unique Identifier overlap (via scispaCy, set-level F1) gives a graded, externally specified reward computed without a model in the loop. We combine it inside GRPO with an entropy-normalised LLM judge, which covers the safety and evidence axes overlap cannot see, and a small consistency penalty on padding and repetition that keeps early-training samples scorable. This three-term composite improves over SFT on Phi-3-mini (3.8B) over MedQA by 2.9% on EM (0.700 vs 0.680) and 39% on Token-F1 (0.202 vs 0.145); on Llama-3.2-3B the corresponding gains are 14% on EM and 35% on Token-F1. We report Token-F1 as the primary metric because it credits partially-correct clinical content that EM discards at this open-generation scale. Main-table results are means over 3 seeds with standard deviations below 0.005. The method transfers to PubMedQA, where training on the PubMedQA train set with the same composite reward improves Token-F1 over SFT by 22% on Phi-3-mini and 17% on Llama-3.2-3B without retuning. A reward ablation on Phi-3, varying the judge-ontology split at a fixed consistency weight, attributes 3 EM points to the ontology term, the contribution that catches entity substitutions the judge cannot. Three negative findings constrain the design: DPO under random negatives underperforms SFT for strong-prior models but helps the weakest-prior one; PPO under a sparse neural reward diverges; GRPO with KL-in-loss collapses at 7B.

0.27

Option-Aware Retrieval and Task-Specific VLM Adaptation for Medical VQA

cs.AI cs.CLcs.CV ·2026-09-14 ·Tristan Kirscher, Niklas C. Koser, Soren Pirk
top venue similarity 0.65
Abstract

We describe our submission to the MedReason 2026 challenge, covering multiple-choice (MCQ) and open-ended (OE) medical visual question answering (VQA) under fully offline, containerized inference. Our first finding is that MCQ retrieval must compare answer \emph{semantics} rather than answer labels: labels are independently assigned per question, so copying a retrieved neighbor's label transfers no useful information, whereas scoring each current option's text against correct-answer text from similar training cases raises retrieval-only accuracy from 20.0\% to 57.5\% on a 200-case retrieval-excluded development holdout. Our second finding attributes the submitted system's accuracy: holding the task-specific MCQ Low-Rank Adaptation (LoRA) adapter fixed and varying the number \(k\) of in-prompt retrieved examples changes accuracy by at most one case --- 187/200 (93.5\%) at both \(k=0\) and the adapter's training-time \(k=1\), 188/200 (94.0\%) at the packaged runtime's default \(k=3\) --- and the submitted confidence-gated override adds no net accuracy on top of \(k=3\), selecting the VLM in 198/200 cases. With the final MCQ adapter fixed, retrieval changes accuracy by at most one case, and gating provides no net gain. On 20 OE cases, token-F1 and RaTEScore~\cite{zhao2024ratescore} decrease as \(k\) grows, but paired sign tests on token-F1 differences are nonsignificant (\(p \ge 0.29\)); a single-annotator comparison found 6/20 wrong-anchor errors for the final configuration and 14/20 for an earlier configuration that jointly differed in routing, adapter, and prompting. The system reaches 94.0\% MCQ accuracy on the development holdout and 93.20\% on the organizer's official pre-evaluation, versus 29.43\% for the off-the-shelf reference baseline, while both of the organizer's open-ended scores are lower than that baseline's (ground-truth agreement 1.245 versus 1.588, visual accuracy 1.995 versus 2.696, each out of 4).

0.31

Scaling Clinical Judgment to Evaluate Medical AI

cs.AI ·2026-09-11 ·Thomas A. Buckley, Zahir Kanjee, Peter G. Brodeur, Byron Crowe, Anthony M. Pettinato +13 more
benchmark similarity 0.65
Abstract

Blinded physician evaluation has been considered by many to be the gold standard for assessing clinical reasoning in large language models (LLMs). This is difficult to scale; thus, prior studies typically rely on small physician panels, often from a single institution or specialty, which both limits the scientific questions investigated and makes it unclear whether findings would be reproduced with a different set of evaluators. To more rigorously and scalably study clinical reasoning in AI models, here we introduce PrecepTron, an LLM fine-tuned for physician-level evaluation of open-ended responses. PrecepTron was trained using low-rank adaptation (LoRA) of a 32-billion-parameter model on a small number of physician examples. We also release GRAND-ROUNDS, a new large-scale physician-annotated benchmark of 9,217 scored responses from 160 clinicians across seven studies. We show that frontier LLMs in typical "LLM-as-a-judge" approaches often disagree with physicians and with each other, but fine-tuning PrecepTron on a small number of cases enables physician-level consistent scoring across tasks. We use PrecepTron to reproduce headline findings from five influential studies assessing LLMs for clinical care in JAMA, Science, and Nature Medicine without new human grading. Using PrecepTron, we then pose new questions about how LLMs reason in medicine that would have been infeasible with human grading alone, including measuring the diagnostic accuracy of frontier LLMs when clinical cases are provided piecemeal, even token by token. Together, PrecepTron and GRAND-ROUNDS provide a foundation for reproducible, large-scale study of how LLMs reason in medicine. All code, data, and labels are made freely available for researchers.

0.14

Improving JEV Entailment Reranking with Span Readouts and Selective Adaptation

cs.CL ·2026-10-26 ·Haocheng Mei, Yuchuan Tian, Ye Yuan, Enhua Wu, Chao Xu +3 more
code/data similarity 0.63
Abstract · 25 pages, 3 figures. Project page: https://github.com/Mei-TN/Jev-reranking

JEV decision models pair a language model backbone with a lightweight scoring head to select among natural-language options. Direct selection compares candidate answers within one request, whereas entailment reranking evaluates each candidate in a separate natural language inference (NLI) request over fixed relation options. We examine whether the readout and adaptation choices used for direct selection remain effective for cross-request reranking. We combine a mean-span readout with selective backbone adaptation. Mean-span pooling replaces the option-ending pointer with an average of the contextualized states inside each NLI option, without adding head parameters. Selective adaptation retains low-rank updates in attention and gated DeltaNet projections while removing feed-forward adapters. On MC11, which averages accuracy over eleven reranking configurations from seven sources, selective adaptation improves NeoHorse-1-4B accuracy over the all-module baseline while cutting trainable parameters by more than half, and mean-span pooling yields further consistent gains at the same parameter count.

0.43