CS Paper Radar

Decomposition-Guided Curvelet Thresholding for Sharp-to-Soft CT Kernel Conversion

Mahmoud Nasr, Jan K. Argasinski, Krzysztof Brzostowski, Adam Piorkowski

cs.CV ·submitted 2026-10-05 08:25 UTC · v1
published

Abstract

Image denoising is a crucial task in image processing, focused on improving image quality by minimizing noise while maintaining essential structural elements. This study presents a hybrid denoising framework that combines several decomposition techniques, including empirical mode decomposition (EMD), variational mode decomposition (VMD), multichannel EMD (MEMD), and bidimensional EMD (BEMD), with curvelet transform thresholding. Each decomposition mode undergoes processing through both soft and hard thresholding, and the denoised modes are combined to rebuild the final image. Comprehensive evaluations of standard CT image datasets reconstructed with various kernels (B50, B46, B41, B36) reveal substantial enhancements in denoising efficacy. VMD consistently achieves the highest peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), signifying exceptional noise reduction and feature preservation. The study analyses the trade-offs between soft and hard thresholding: soft thresholding maintains intricate visual details, whilst harsh thresholding provides enhanced noise reduction. The suggested method surpasses traditional techniques in both reference and non-reference quality criteria, indicating its potential for broader application in medical imaging and future incorporation with adaptive thresholding algorithms.

DOI
10.1007/978-3-032-37933-7_39

Closest papers

Nearest neighbours by meaning across the whole index.

A BEMD-Based Quaternion Filtering Approach Sharp-to-Soft Kernel CT Image Conversion

cs.CV ·2026-10-05 ·Mahmoud Nasr, Jan K. Argasinski, Krzysztof Brzostowski, Adam Piorkowski
publishedunusual similarity 0.63
Abstract

The quality of computed tomography (CT) images is significantly affected by the selection of reconstruction kernels: sharp kernels improve spatial resolution but increase noise, whereas soft kernels diminish noise at the expense of edge clarity. This study presents an innovative enhancement framework utilising Bidimensional Empirical Mode Decomposition in conjunction with Quaternion Bilateral Filtering (BEMD--QBF) to convert sharp-kernel CT images into representations resembling soft-kernels, while maintaining critical anatomical structures. The technique disaggregates each image into intrinsic mode functions via BEMD and analyzes them inside a cohesive quaternion framework to attain efficient noise reduction and structural integrity. The proposed methodology is evaluated using several reconstruction kernels (B50, B46, B41, B36, B35, B31) and compared with recognised filtering strategies, including Non-Local Means, Anisotropic Diffusion, Bilateral Filtering, and Quaternion Bilateral Filtering. Quantitative evaluations of the Structural Similarity Index (SSIM) and Peak Signal-to-Noise Ratio (PSNR) indicate that BEMD-QBF consistently attains superior structural fidelity and competitive noise reduction across all evaluated kernels. The results underscore the efficacy of the proposed strategy as a viable approach to enhancing post-reconstruction CT images, yielding superior image quality without requiring access to raw projection data.

0.40

Poisson Image Denoising Using Minimax Concave and Reweighted $\ell_1$ Penalties: Nonblind and Blind Approaches

cs.CV math.NA ·2026-09-07 ·Reza Parvaz
similarity 0.60
Abstract

Images are important tools in various sciences. Despite the development of photo-taking tools, creating clear and image without noise remains challenging in practice. In particular, Poisson noise has an effect on medical and astronomical images, and reduces their quality. Additionally, blur is another factor that has an effect on image quality. The problem of image restoration becomes very complicated when we have no information about the Point Spread Function (PSF). These types of problems are known as blind case. However, in some images, such as some astronomical images, the type of PSF can be specified, and these types of problems are known as nonblind problems. Total Variation (TV) is a widely used method for solving such inverse problems, where the selection of the penalty function is the most critical factor that affects the method's performance. In this paper, to improve edge preservation, we employ a reweighted $\ell_1$-regularization of the fractional order derivative. Furthermore, we propose a nonblind and blind image deblurring approach under Poisson noise using the Minimax Concave Penalty (MCP), which is a continuous, sparsity promoting, and nearly unbiased regularizer. This formulation leads to a nonconvex optimization model. To solve the proposed model, we introduce an efficient numerical algorithm based on the Alternating Direction Method of Multipliers (ADMM) and provide an analysis of its convergence. Finally, the effectiveness of the proposed algorithm are demonstrated through extensive experiments on various images.

0.27

Neural Disjunctive Normal Forms for Learning Exact Rank Filters

cs.CV cs.LG ·2026-10-23 ·Diego Marcondes, Wonder A. L. Alves, Ronaldo F. Hashimoto
unusual similarity 0.58
Abstract · 12 pages, 4 figures, 2 tables

Gradient-based learning of morphological operators is hindered by locally sparse derivatives with respect to the structuring elements. We develop a method for learning rank filters that retains exact operator evaluation while distributing the derivatives across the window. Using threshold decomposition, we construct a neural disjunctive normal form representation and establish a sufficient condition for exactness with integer-valued images and structuring elements. We then derive a smooth surrogate from the unique root of a smooth threshold equation. Implicit differentiation gives closed-form derivatives with normalised local weights, whose distribution is controlled by a smoothing parameter. These derivatives are used in a straight-through procedure: the forward pass evaluates the exact rank filter, while the backward pass uses the surrogate. For fixed ranks, the procedure learns real-valued structuring elements of any rank filter, including the median, and extends to compositions, infima, and suprema of rank filters. Experiments on image denoising using MNIST and Fashion-MNIST and retinal vessel segmentation show that, starting from a generic random initialisation, the proposed approach consistently improves performance over training with exact subgradients in every setting. In image denoising, our best network also outperforms smooth morphological networks in all settings. On vessel segmentation, the learned erosions recover structuring elements that fit the vessels, as theoretically expected, whereas most of those trained with exact subgradients remain close to their initialisation.

0.27

A deep dictionary network-based foundation model for ultra-low-dose CT denoising

eess.IV cs.CVcs.LG ·2026-09-11 ·Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu +1 more
similarity 0.57
Abstract

Ultra-low-dose computed tomography (ULDCT) reduces radiation exposure but suffers from severe noise that degrades diagnostic image quality. Existing deep learning-based denoising methods are typically trained in an organ-specific fashion, resulting in limited generalization across heterogeneous multi?organ imaging scenarios. Foundation models present a promising all-in-one paradigm for unified multi-organ denoising. However, their architectures suffer from poor interpretability and rely on heuristic training strategies. To address these limitations, we propose an architecture?interpretable foundation model based on the deep dictionary network (DDN) for unified multi-organ ULDCT denoising. Inspired by multilayer sparse representation theory, DDN cascades convolutional sparse coding layers with iterative soft-thresholding, providing inherent architectural interpretability. Furthermore, a dynamic dictionary module and a threshold generation module are embedded within each layer to enhance representation ability. We conduct DDN pre-training on more than one million multi-organ normal-dose CT images by recovering clean images from Gaussian-noised inputs. Sparse regularization is additionally imposed on latent feature representations, guiding the network to learn compact and noise-robust priors. The complete architecture is jointly fine-tuned on multi-organ ULDCT datasets, enabling a single unified model to perform denoising across diverse anatomical regions. Extensive experiments validate that our proposed method achieves state-of-the?art performance and consistently surpasses competing ULDCT methods across all mul

0.28

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.55
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.55
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.55
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

Image Denoising Using Lower Semi-Frames

eess.IV cs.CV ·2026-08-21 ·Hemalatha M, P. Sam Johnson
similarity 0.55
Abstract

A blind image denoising framework based on an infinite directional lower semi-frame (DLSF) is proposed for additive white Gaussian noise. The model employs scale-dependent directional analysis with resolvent regularization of the unbounded semi-frame operator. Noise variance is estimated directly in the DLSF domain by modeling the joint covariance of four directional difference channels and applying covariance whitening to obtain a chi-square statistic. A lower-tail moment estimator provides blind noise estimation without median absolute deviation. The estimated noise level is incorporated into channel-wise Wiener-type shrinkage and canonical-dual synthesis, followed by a data-consistent iterative reconstruction with automatic stopping. Experiments on three standard grayscale images at noise levels 15--30 yield a mean relative noise-estimation error of 3.28\%, with average improvements of 7.45 dB in PSNR and 0.367 in SSIM. At 30/255 noise, the estimation error decreases to 1.73\%, with a mean PSNR gain of 8.31 dB. Results demonstrate effective noise suppression and structural preservation, with the strongest performance on smooth and edge-dominated images.

0.27