CS Paper Radar

A BEMD-Based Quaternion Filtering Approach Sharp-to-Soft Kernel CT Image Conversion

Mahmoud Nasr, Jan K. Argasinski, Krzysztof Brzostowski, Adam Piorkowski

cs.CV ·submitted 2026-10-05 08:52 UTC · v1
publishedunusual

Abstract

The quality of computed tomography (CT) images is significantly affected by the selection of reconstruction kernels: sharp kernels improve spatial resolution but increase noise, whereas soft kernels diminish noise at the expense of edge clarity. This study presents an innovative enhancement framework utilising Bidimensional Empirical Mode Decomposition in conjunction with Quaternion Bilateral Filtering (BEMD--QBF) to convert sharp-kernel CT images into representations resembling soft-kernels, while maintaining critical anatomical structures. The technique disaggregates each image into intrinsic mode functions via BEMD and analyzes them inside a cohesive quaternion framework to attain efficient noise reduction and structural integrity. The proposed methodology is evaluated using several reconstruction kernels (B50, B46, B41, B36, B35, B31) and compared with recognised filtering strategies, including Non-Local Means, Anisotropic Diffusion, Bilateral Filtering, and Quaternion Bilateral Filtering. Quantitative evaluations of the Structural Similarity Index (SSIM) and Peak Signal-to-Noise Ratio (PSNR) indicate that BEMD-QBF consistently attains superior structural fidelity and competitive noise reduction across all evaluated kernels. The results underscore the efficacy of the proposed strategy as a viable approach to enhancing post-reconstruction CT images, yielding superior image quality without requiring access to raw projection data.

DOI
10.1007/978-3-032-36871-3_22

Closest papers

Nearest neighbours by meaning across the whole index.

Decomposition-Guided Curvelet Thresholding for Sharp-to-Soft CT Kernel Conversion

cs.CV ·2026-10-05 ·Mahmoud Nasr, Jan K. Argasinski, Krzysztof Brzostowski, Adam Piorkowski
published similarity 0.63
Abstract

Image denoising is a crucial task in image processing, focused on improving image quality by minimizing noise while maintaining essential structural elements. This study presents a hybrid denoising framework that combines several decomposition techniques, including empirical mode decomposition (EMD), variational mode decomposition (VMD), multichannel EMD (MEMD), and bidimensional EMD (BEMD), with curvelet transform thresholding. Each decomposition mode undergoes processing through both soft and hard thresholding, and the denoised modes are combined to rebuild the final image. Comprehensive evaluations of standard CT image datasets reconstructed with various kernels (B50, B46, B41, B36) reveal substantial enhancements in denoising efficacy. VMD consistently achieves the highest peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), signifying exceptional noise reduction and feature preservation. The study analyses the trade-offs between soft and hard thresholding: soft thresholding maintains intricate visual details, whilst harsh thresholding provides enhanced noise reduction. The suggested method surpasses traditional techniques in both reference and non-reference quality criteria, indicating its potential for broader application in medical imaging and future incorporation with adaptive thresholding algorithms.

0.34

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

eess.IV cs.CEcs.CVq-bio.QM ·2026-09-06 ·Chengkai Wang, Luoyu Hong, Yiting Zhao, Jiamin Wang, Xiang Feng +5 more
top venue similarity 0.53
Abstract · ECCV 2026

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

0.47

DoReMe: Dual optimization of Reconstruction and Motion estimation for self-navigated free-breathing abdominal MRI using Gaussian Splatting

eess.IV cs.CVphysics.med-ph ·2026-10-13 ·Majd Helo, Dominik Nickel, Thomas Kuestner
similarity 0.53
Abstract · 25 pages, 2 tables and 7 figures

Purpose: Free-breathing abdominal MRI is limited by respiratory motion, which introduces image artifacts and k-space inconsistencies. Existing reconstruction approaches often depend on pre-estimated motion fields or external respiratory surrogate signals. We propose a coupled reconstruction-motion estimation algorithm for self-navigated free-breathing acquisition, in which motion is represented by compact Gaussian primitives and jointly refined with the image estimates during iterative reconstruction. Methods: An iterative reconstruction that alternates between data consistency updates and motion modelling was proposed. Respiratory motion was represented using Gaussian primitives. A Gaussian splatting was integrated into the reconstruction algorithm. The method was evaluated on self-navigated free-breathing Cartesian gradient-echo (GRE) acquisition in four healthy volunteers, including retrospective scan shortening experiments, and was compared with regularized compressed sensing (CS) reconstruction. Results: Respiratory motion states were reconstructed in approximately 1.5 min. Compared with CS, the proposed method improved visual image quality, particularly in coronal liver views, and better preserved anatomical structures in retrospectively shortened acquisitions. These findings provide proof of concept for the proposed method. Conclusion: The proposed coupled reconstruction-motion estimation algorithm improved visual image quality compared with CS alone. Gaussian primitives provided a compact and sufficiently flexible representation of nonrigid respiratory motion with practical runtime, supporting further scanner integration and validation in larger cohorts.

0.22

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.53
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

AD-GS: Anatomical Density-guided 3D Gaussian Splatting for Sparse-View Dental CBCT Reconstruction

cs.CV ·2026-10-10 ·Zonglin Li, Kexian Xie, Feiran Li, Chu Zhou, Yixing Huang +3 more
code/data similarity 0.52
Abstract

Sparse-view Cone-Beam Computed Tomography (CBCT) reconstruction is essential for reducing radiation dose and scan effort, but remains underconstrained due to limited projection information. Recent 3D Gaussian Splatting (3DGS)-based CBCT reconstruction methods rely on gradient-driven densification, which becomes unstable under sparse acquisition and often leads to over-smoothed structures. We propose AD-GS, an Anatomical Density-guided 3D Gaussian Splatting framework that formulates Gaussian densification as an attenuation-aware Markov Chain Monte Carlo (MCMC) sampling process. By interpreting Gaussians as samples from an underlying anatomical attenuation distribution, AD-GS adaptively concentrates representation capacity in high-attenuation regions, enabling sharper structural boundaries under sparse projections. To further constrain reconstruction, we incorporate a semantic regularization based on zero-shot features from Segment Anything in Medical Images, enforcing multi-view consistency through semantic priors. Experiments on the ToothFairy3 dental CBCT dataset demonstrate that AD-GS achieves superior structural fidelity and boundary preservation compared with existing 3DGS-based approaches under sparse-view settings within the dental and maxillofacial setting. Code is available at https://github.com/yulinjiaxue/AD-GS-BMVC2026.

0.29

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.51
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

DeBoneDiT: Depth-Driven Conditional Bridge Diffusion Transformers for Bone Suppression in Chest X-Ray Images

cs.CV ·2026-10-14 ·Yifei Sun, Fenglei Fan, Junhao Jia, Wenming Deng, Hongxia Xu +2 more
benchmark similarity 0.51
Abstract · 19 pages, 13 figures

Chest X-Ray (CXR) is a primary modality for diagnosing pulmonary diseases, yet the overlap of bony structures often obscures critical radiographic findings, increasing the risk of diagnostic uncertainty. While Dual-Energy Subtraction (DES) is the clinical benchmark for bone suppression, its widespread adoption is primarily hindered by specialized hardware requirements and increased radiation exposure. Recently, diffusion-based generative models have shown promise for this task, yet they are still constrained by reconstruction-biased latent compression, prior-induced domain gap, and a scarcity of high-quality paired datasets. To address these challenges, we propose DeBoneDiT, a depth-driven conditional bridge diffusion Transformer architecture for efficient high-resolution bone suppression. We first introduce Depth Auto-Encoder (DAE), a structure-aware vision tokenizer for latent compression. By incorporating a multi-level depth feature loss derived from the pretrained Depth Anything V2 encoder, DAE preserves both visual fidelity and structural consistency. Second, we formulate bone suppression as a source-conditioned Brownian bridge diffusion process, leveraging CXRs as both the diffusion prior and structural guidance to narrow the source-to-target domain gap and maintain anatomical plausibility. Furthermore, we have constructed and released SZCH-X-Rays, the largest publicly available high-quality paired dataset for bone suppression to date, comprising 741 pairs of CXR and DES soft tissue images. Extensive experiments and downstream evaluation demonstrate that DeBoneDiT achieves superior bone suppression performance with reduced computational overhead.

0.19

SONAR: A Structure-Consistent Neural Operator for Null-Space-Aware Sparse View CT Reconstruction

eess.IV cs.CV ·2026-09-12 ·Song Ni, Haijun Yu, Haodong Li, Changsheng Fang, Shuyi Fan +2 more
similarity 0.51
Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time but remains severely ill-posed because incomplete projections poorly constrain null-space information. Existing learning-based methods often estimate this information in high-dimensional image space, conflate physical measurement errors with prediction errors, and depend on fixed discretizations. We propose SONAR, a Structure-Consistent Neural Operator for Null-Space-Aware Reconstruction. Instead of recovering the full null-space component, SONAR predicts a low-dimensional null-space-aware representation from the acquired projections as pseudo-measurements. It separates measurement and pseudo-measurement residuals, lifts them into the image domain through physics operators, and applies independent neural operators to constrain their structural effects, thereby accommodating admissible errors while suppressing unsupported structures. To support cross-discretization reconstruction, an anisotropic U-shaped neural operator models the periodic angular and nonperiodic detector dimensions using direction-dependent continuous supports, while image-domain neural operators re-discretize continuous kernels on target grids. These components form an optimization-inspired unrolled network. Experiments on simulated AAPM and clinical MARS photon-counting CT data demonstrate consistent improvements across seen and unseen view settings and unseen image resolutions. On AAPM dataset, SONAR improves PSNR by 1.87~dB at 62 views and by 7.63~dB under zero-shot transfer to a $512\times512$ grid over the strongest competing methods. SONAR also achieves the best overall performance in all clinical settings evaluated, demonstrating accurate, structurally reliable, and discretization-robust sparse-view CT reconstruction.

0.26