CS Paper Radar

From Simulation to Suture Lines: Computational Fluid Dynamic Simulation-Guided Baffle Construction for Complex Biventricular Repair

Alexander K. Reed, Elena Sabdy Martinez, Alexander D. Kaiser, Amit Sharir, Caio Carcaioli Bonin, Perry S. Choi, Shiraz A. Maskatia, Alison L. Marsden, Michael R. Ma

cs.CE ·submitted 2026-10-06 20:15 UTC · v1

Abstract

Biventricular repair is favored for children with complex double-outlet right ventricle (DORV) to eliminate the long-term morbidity of single ventricle physiology. However, creating a baffle that maintains adequate cross-sectional area while limiting incursion on the tricuspid valve apparatus is challenging in a distorted, arrested heart. Three-dimensional (3D) models have aided baffle design with anatomic visualization but analytic approaches, including computational fluid dynamic (CFD) simulation support, have not yet been incorporated into clinical workflows. We present the preoperative, prospective construction of a DORV repair baffle guided by a semi-automated area-preserving algorithm and CFD analysis.

Closest papers

Nearest neighbours by meaning across the whole index.

Learning to Beat: Phenotype-Guided Latent Flow with Regional Motion Priors for Biventricular Motion Synthesis

cs.CV cs.AI ·2026-08-20 ·Xuan Yang, Xiaohan Yuan, Hao Li, Lingyu Chen, Yanan Liu +2 more
similarity 0.55
Abstract · 14pages, 10 figures

Full-cycle biventricular geometry is essential for characterizing cardiac function. However, dense and temporally consistent 3D+t biventricular meshes are not routinely available, whereas end-diastolic (ED) anatomy can often be obtained reliably. We therefore investigate full-cycle biventricular motion synthesis from a single ED mesh. This task is challenging because cardiac deformation is spatially heterogeneous and phenotype dependent, while conventional global generative models often obscure localized motion patterns. In this study, we propose a region-specific and phenotype-adaptive framework that integrates motion-informed functional parcellation with conditional latent flow. A functional partition learned from reconstructed motion organizes the ventricular surface into regions with coherent dynamics and enables topology-aware regional feature exchange. A phenotype-conditioned rectified-flow model subsequently maps the ED anatomy to full-cycle motion latents through fine-grained conditioning and prototype-routed motion adapters. An optional control branch further incorporates available motion descriptors for controllable synthesis. Experiments on ACDC, M\&Ms, and M\&Ms-2 demonstrate consistent improvements in geometric accuracy and functional fidelity. Under ED-only synthesis, our method achieves biventricular ASSD, HD95, and vRMSE of \(1.49\pm0.34\)~mm, \(3.77\pm1.06\)~mm, and \(3.31\pm1.03\)~mm, respectively, outperforming all competing methods. Complementary functional and robustness evaluations further demonstrate that the synthesized sequences preserve physiologically plausible ventricular dynamics and generalize across cohorts and disease phenotypes. The code will be released publicly upon acceptance of the manuscript for publication.

0.27

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

cs.CV ·2026-08-19 ·Arnaud Boutillon, Naomi Clarke, Tomas Woodgate, Daniel West, Alina Schneider +6 more
similarity 0.53
Abstract

Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container https://hub.docker.com/r/aboutill/sparc and is currently deployed at our institution as a clinical research tool.

0.37

Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography

cs.CE ·2026-11-13 ·Davide Tondi, Vijay K. Dubey, Collin E. Haese, Colton J. Kostelnik, Mrudang Mathur +21 more
similarity 0.53
Abstract · Draft manuscript of 3D TEE to FEM modelling pipeline for human tricuspid valves

Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.

0.39

Mind the Gap: Mesh-Guided Repair of Broken Vessels

cs.CV ·2026-09-24 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published similarity 0.50
Abstract · Accepted at ShapeMI 2026 (Shape in Medical Imaging), MICCAI 2026 Workshop. 17 pages, 5 figures, 3 tables

Vessel segmentation is commonly optimized as voxel-wise classification, but small local errors can strongly disrupt vascular connectivity while having little effect on overlap scores. This is particularly problematic for downstream analyses that rely on centerlines, branches, connected components, or graph structure. We propose a mesh-guided post-processing framework for repairing broken vessel segmentations produced by nnU-Net. For each predicted binary mask, a deformable template mesh is fitted to the mask surface in physical space and used as a case-specific geometric scaffold. The fitted mesh is not voxelized as the final segmentation; instead, it guides conservative reconnection of disconnected components by proposing or validating thin bridge candidates under foreground-growth constraints. We evaluated this approach in three vascular anatomies using AortaSeg24 and SEGA for the aorta, TopCoW for the Circle of Willis, and PARSE for the pulmonary arteries. Performance is measured using Dice, connected-component Dice (ccDice), and the Betti-0 number. Across these datasets, repair substantially improved connectivity while preserving overlap: Dice remained nearly unchanged, whereas ccDice increased from 0.596 to 0.992 for aorta, from 0.722 to 0.835 for TopCoW, and from 0.028 to 0.862 for PARSE. The FOMAML meta-initialization further accelerated the fitting per-case, supporting practical mesh-based repair of the vascular topology. These results suggest that explicit mesh representations can provide a useful geometric prior for correcting topological failures in otherwise accurate voxel segmentations.

0.33

CardioDrift: Automatic Cardiac Motion Tracking on a 3D Atlas Mesh via Shape-aware Coherent Point Drift with Slice Shift Correction

cs.CV ·2026-11-04 ·Reza Akbari Movahed, Abuzar Rezaee, Shatha Alamri, Edmond S. L. Ho, Fani Deligianni +1 more
similarity 0.49
Abstract

Automatic cardiac motion tracking from cine cardiac magnetic resonance (CMR) imaging is essential for quantifying myocardial motion abnormalities associated with cardiovascular disease. Existing methods fall into two groups: those that represent motion without anatomical correspondence across subjects and therefore limit inter-subject motion assessment; and those that represent motion with globally corresponding points, which typically require a time-consuming and error-prone semi-automatic step to fit a cardiac atlas to the subject space. To address these limitations, this study proposes CardioDrift, a fully automatic, atlas-based probabilistic framework that represents subject-specific cardiac motion on a 3D atlas mesh with globally corresponding points. The Coherent Point Drift (CPD) formulation is generalised to jointly register the atlas surfaces of multiple cardiac regions to the anatomically corresponding contours extracted from cine CMR segmentation maps throughout the cardiac cycle. Slice-shift correction is embedded in the same probabilistic model, estimating slice-wise translations that suppress the misalignment artefact limiting atlas-fitting accuracy. Evaluation on 1301 randomly selected UK Biobank subjects and the M&M dataset, CardioDrift attains Dice similarity coefficients (DSCs) of $92.23\pm8.70\%$, $82.11\pm7.56\%$, and $88.69\pm4.13\%$ for the left ventricle (LV), myocardium (Myo), and right ventricle (RV), exceeding the strongest baseline on every distance and overlap metric of both datasets.

0.27

AI-Based Multi-View Echocardiographic Image Synthesis using Dynamic Shape Control

cs.CV cs.AI ·2026-11-13 ·João Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge +1 more
published similarity 0.48
Abstract · 5 pages, 2 figures, accepted for publication in the Proceedings of the 2026 IEEE International Ultrasonics Symposium (IUS 2026)

Although automated methods have improved echocardiographic workflows, progress remains constrained by the need for large, well-annotated datasets. As the development of clinical databases is often limited by ethical and logistical challenges, synthetic data generation has emerged as a promising alternative. However, existing approaches commonly rely on left ventricle shape-based supervision or are tailored to specific cardiac views, limiting the generation of additional standard and unconventional imaging planes and the preservation of multi-view consistency across cardiac chambers. To address these limitations, we propose a novel framework for shape-controlled synthesis of multi-view echocardiographic sequences. First, multi-view cross-sections are extracted from dynamic whole-heart meshes. Ultrasound-like appearance is then introduced through a two-stage AI-based pipeline. In Stage 1, an unpaired GAN-diffusion model translates these cross-sections into realistic echocardiographic frames. As this translation is performed independently at the frame level, Stage 2 employs masked video reconstruction to improve temporal coherence and cardiac motion. Evaluation demonstrated high frame-level realism for both stages, while the integration of Stage 2 substantially improved video-level motion quality and temporal consistency. Overall, the proposed framework enables the generation of realistic multi-view echocardiographic sequences from diverse cardiac models, providing a scalable source of annotated data for dataset augmentation and the development of multi-view cardiac assessment methods.

0.33

Physics Informed Neural Network model for the dynamical study of Abdominal Aortic Aneurysm

cs.AI physics.flu-dyn ·2026-09-14 ·Adrián Robles Arques, Martín Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo
similarity 0.47
Abstract · 38 pages, 9 figures and 2 tables

We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodynamic behaviour in the human aorta. The model incorporates a time-resolved simulation of pulsatile blood flow over a two-minute interval, enabling the extraction of pressure and velocity fields with high temporal fidelity. The mechanical stress exerted on the aortic wall was quantified through Laplace's law, with temporal averaging applied to derive representative stress distributions. This approach circumvents the computational overhead associated with conventional computational fluid dynamics (CFD) methods by eliminating mesh generation and exploiting the automatic differentiation capabilities inherent to neural networks. The proposed methodology demonstrates that PINNs can serve as an efficient and accurate alternative for modelling complex vascular flow phenomena, offering significant advantages in scalability and computational cost reduction while maintaining physical consistency.

0.20

MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision

cs.CV ·2026-09-08 ·Quanxin Zheng, Shuai Zhao
code/data similarity 0.47
Abstract

Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. We evaluate three weak-mask generators -- LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning -- and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.928 Dice and 3.80mm HD95 with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.

0.24