Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography

Davide Tondi, Vijay K. Dubey, Collin E. Haese, Colton J. Kostelnik, Mrudang Mathur, Sumedh Seetharam, Amin Silvani, Alison M. Pouch, Jakob Christoph Voran, Felix Kreidel, Marnie Goldmann, Adrian Buganza Tepole, William D. Meador, Marcin Malinowski, Magda Piekarska, Austin Goodyke, Issam D. Moussa, Matthew R. Summers, Robyn Fong, Matthew M. Duda, Kelly C. Higa, William Hiesinger, Tomasz A. Timek, Jan N. Fuhg, Emiliano Votta, Manuel K. Rausch

cs.CE ·submitted 2026-11-13 18:37 UTC · v1

Abstract

Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.

Comment
Draft manuscript of 3D TEE to FEM modelling pipeline for human tricuspid valves

Closest papers

Nearest neighbours by meaning across the whole index.

Label-Preserving Fourier Domain Adaptation with Generative-AI and Real Style Donors for 3D Mitral Valve Segmentation

eess.IV cs.CV ·2026-11-03 ·Javeria Javed, Ahmed Salim, Muhammad Mahboob Ur Rahman
similarity 0.59
Abstract · 7 pages, 1 figure, 3 tables, submitted to IEEE for possible publication

Accurate segmentation of the mitral valve from three-dimensional transesophageal echocardiography (3D TEE) is severely restricted by the scarcity of publicly available expert- annotated volumetric datasets. To address this critical limitation, we investigated Fourier Domain Adaptation (FDA), utilizing general-purpose generative-AI images (from platforms like Chat- GPT, Google Gemini, and Microsoft MAI) as annotation-free style donors for 3D mitral valve segmentation. We employed a DeepMitral residual U-Net model on the public MVSeg2023 dataset, comparing six conditions over three runs: real-only training, traditional augmentation, FDA with each generative source, and a non-AI FDA control using real-image style donors, plus an optimization-matched real-only control and a \b{eta} sensitivity analysis. Case-level paired testing showed that FDA with these generative sources led to significant reductions in boundary- and surface-related errors across all three donor conditions relative to the primary real-only baseline. However, the impact on the core segmentation metric, Generalized Dice Score (GDS), proved generator-dependent. ChatGPT-FDA showed a significant GDS advantage over the optimization-matched control but not over the primary baseline, and Gemini-FDA showed no significant GDS difference. Notably, only MAI-FDA provided a statistically robust and significant increase in GDS compared to the primary baseline. The \b{eta} sensitivity was not robust across training runs. These findings confirm that FDA remains an important augmentation mechanism. While generative-AI images offer a practical means of acquiring style diversity without new annotations, the non-AI control performed comparably to ChatGPT-FDA, so we do not conclude that this approach is superior to training with real-image donors.

0.27

AI-Based Multi-View Echocardiographic Image Synthesis using Dynamic Shape Control

cs.CV cs.AI ·2026-11-13 ·João Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge +1 more
published similarity 0.57
Abstract · 5 pages, 2 figures, accepted for publication in the Proceedings of the 2026 IEEE International Ultrasonics Symposium (IUS 2026)

Although automated methods have improved echocardiographic workflows, progress remains constrained by the need for large, well-annotated datasets. As the development of clinical databases is often limited by ethical and logistical challenges, synthetic data generation has emerged as a promising alternative. However, existing approaches commonly rely on left ventricle shape-based supervision or are tailored to specific cardiac views, limiting the generation of additional standard and unconventional imaging planes and the preservation of multi-view consistency across cardiac chambers. To address these limitations, we propose a novel framework for shape-controlled synthesis of multi-view echocardiographic sequences. First, multi-view cross-sections are extracted from dynamic whole-heart meshes. Ultrasound-like appearance is then introduced through a two-stage AI-based pipeline. In Stage 1, an unpaired GAN-diffusion model translates these cross-sections into realistic echocardiographic frames. As this translation is performed independently at the frame level, Stage 2 employs masked video reconstruction to improve temporal coherence and cardiac motion. Evaluation demonstrated high frame-level realism for both stages, while the integration of Stage 2 substantially improved video-level motion quality and temporal consistency. Overall, the proposed framework enables the generation of realistic multi-view echocardiographic sequences from diverse cardiac models, providing a scalable source of annotated data for dataset augmentation and the development of multi-view cardiac assessment methods.

0.33

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

cs.CV ·2026-08-19 ·Arnaud Boutillon, Naomi Clarke, Tomas Woodgate, Daniel West, Alina Schneider +6 more
similarity 0.57
Abstract

Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container https://hub.docker.com/r/aboutill/sparc and is currently deployed at our institution as a clinical research tool.

0.37

A Physics-Conditioned Neural Operator for Generalization of Atrioventricular Valve Mechanics across Pressure and Tissue Properties

cs.LG ·2026-09-20 ·Shawn Koohy, Wensi Wu, Matthew A Jolley, Paris Perdikaris
similarity 0.56
Abstract · Preprint submission v2

Mitral and tricuspid regurgitation are the most common regurgitant valvular lesions, yet only a minority of severe cases undergo corrective surgery. Rapid assessment of valve mechanics could enable earlier, more precise intervention, but finite element (FE) analysis is slow to repeat across the many loading and tissue-property values of interest, which for a given valve are not known in advance. We introduce the Physics-Conditioned Neural Operator (PCNO), a transformer-based neural operator predicting leaflet displacement, strain, and stress fields conditioned on systolic blood pressure and tissue properties. PCNO is trained on, and evaluated against, FEBio simulations of functional and regurgitant mitral and tricuspid valves and of three mitral pathologies. With pressure and all material parameters simultaneously outside the training support, displacement error against FE reaches 4.48% and the mean errors of unsupervised geometric measures of valve function stay within 3.5%, indicating a conditioned solution operator over parameter space rather than an interpolator of the training set. Under this shift, PCNO is also more accurate than graph neural network and graph neural operator baselines trained on the same simulations, with the largest margins in stress.

0.51

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

cs.CV eess.IV ·2026-09-10 ·Weiying Chen, Yuchong Gao, Siyuan Li, Marek Reformat, Rui Zheng +1 more
top venue similarity 0.56
Abstract · Accepted to ECCV 2026. Camera-ready Author Version

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

0.40

SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation

cs.CV physics.med-ph ·2026-09-11 ·Lila Cunge
similarity 0.54
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.

0.12

A Strong Linear Baseline for Whole-Heart Cardiac Shape Completion on CT, with an Open Eleven-Structure Statistical Shape Model

cs.AI ·2026-08-20 ·Matej Gazda, Jakub Gazda, Juraj Gazda, Peter Drotar
publishedbenchmark similarity 0.54
Abstract

Public cardiac cohorts annotate different subsets of the heart, so shapes from separate sources cannot be pooled without shared correspondence. Among released cardiac shape resources, none we identified carries the atrial appendage, pulmonary veins, and caval stumps as separate blocks in one mesh. Completion benchmarks also compare deep models against a least-squares projection onto shape modes, not the conditional estimator the same fitted model implies. We release an eleven- structure cardiac computed-tomography (CT) statistical shape model, built from 383 automatically labelled cases in 11 571-vertex correspondence, and compare completion estimators under one frozen internal split and endpoint. On a 76-case internal list held out from fitting, a closed-form conditional-Gaussian estimator reconstructed the missing non-chamber structures at 3.717 mm mean per-vertex error, averaged equally over one, three, five, and nine observed structures. A five-refit mask-conditioned graph variational autoencoder reached 5.248 mm and nearest-neighbour retrieval 8.931 mm. The paired difference was 1.531 mm (95% confidence interval 1.384 to 1.711), and the ordering held in a raw-coordinate sensitivity arm. Expert manual labels exist for 58 external CT cases, but our registered reference is close enough to score only five structures. There the closed-form estimator again had lower average surface distance, 95th-percentile Hausdorff distance, and Chamfer error for both completed atria. On a second public benchmark of 20 cases the reference was close enough for three of four completed structures, and the same ordering held there. Four structures have no expert reference. The released model and its completion operator support cohort-unification research on aligned CT, not clinical use.

0.34

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.54
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51