A Physics-Conditioned Neural Operator for Generalization of Atrioventricular Valve Mechanics across Pressure and Tissue Properties

Shawn Koohy, Wensi Wu, Matthew A Jolley, Paris Perdikaris

cs.LG ·submitted 2026-09-20 19:23 UTC · v2

Abstract

Mitral and tricuspid regurgitation are the most common regurgitant valvular lesions, yet only a minority of severe cases undergo corrective surgery. Rapid assessment of valve mechanics could enable earlier, more precise intervention, but finite element (FE) analysis is slow to repeat across the many loading and tissue-property values of interest, which for a given valve are not known in advance. We introduce the Physics-Conditioned Neural Operator (PCNO), a transformer-based neural operator predicting leaflet displacement, strain, and stress fields conditioned on systolic blood pressure and tissue properties. PCNO is trained on, and evaluated against, FEBio simulations of functional and regurgitant mitral and tricuspid valves and of three mitral pathologies. With pressure and all material parameters simultaneously outside the training support, displacement error against FE reaches 4.48% and the mean errors of unsupervised geometric measures of valve function stay within 3.5%, indicating a conditioned solution operator over parameter space rather than an interpolator of the training set. Under this shift, PCNO is also more accurate than graph neural network and graph neural operator baselines trained on the same simulations, with the largest margins in stress.

Comment
Preprint submission v2

Closest papers

Nearest neighbours by meaning across the whole index.

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

cs.LG physics.med-phphysics.flu-dyn ·2026-08-31 ·Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
similarity 0.61
Abstract

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.

0.18

Physics Informed Neural Network model for the dynamical study of Abdominal Aortic Aneurysm

cs.AI physics.flu-dyn ·2026-09-14 ·Adrián Robles Arques, Martín Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo
similarity 0.61
Abstract · 38 pages, 9 figures and 2 tables

We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodynamic behaviour in the human aorta. The model incorporates a time-resolved simulation of pulsatile blood flow over a two-minute interval, enabling the extraction of pressure and velocity fields with high temporal fidelity. The mechanical stress exerted on the aortic wall was quantified through Laplace's law, with temporal averaging applied to derive representative stress distributions. This approach circumvents the computational overhead associated with conventional computational fluid dynamics (CFD) methods by eliminating mesh generation and exploiting the automatic differentiation capabilities inherent to neural networks. The proposed methodology demonstrates that PINNs can serve as an efficient and accurate alternative for modelling complex vascular flow phenomena, offering significant advantages in scalability and computational cost reduction while maintaining physical consistency.

0.20

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.57
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03

Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography

cs.CE ·2026-11-13 ·Davide Tondi, Vijay K. Dubey, Collin E. Haese, Colton J. Kostelnik, Mrudang Mathur +21 more
similarity 0.56
Abstract · Draft manuscript of 3D TEE to FEM modelling pipeline for human tricuspid valves

Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.

0.39

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.52
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.51
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

cs.CV physics.med-ph ·2026-11-10 ·Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
similarity 0.51
Abstract · Under review

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

0.17

Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry

cs.AI cs.CGcs.CV ·2026-08-21 ·Madina Kojanazarova, Sidaty El Hadramy, Philippe C. Cattin
similarity 0.50
Abstract

Accurate soft tissue simulation is essential for surgical training, pre-operative planning, and haptic feedback systems. While learning-based surrogate models trained on data using the finite element method (FEM) offer a promising path to real-time inference, their reliability depends on well-calibrated constitutive models. Existing approaches neither provide systematic guidance on model selection across stiffness levels, nor generalize across different tissue stiffnesses or geometries. We perform a comprehensive calibration of hyperelastic constitutive models in the SOFA Framework using gravity-loaded silicone beams with different stiffnesses. Using calibrated simulations as training data, we use a softness conditioned equivariant graph neural network, enabling deformation and force prediction across multiple tissue types and unseen geometries. Our model achieves sub-millimeter mean deformation accuracy at 0.010s inference time, while showing that force prediction quality is directly tied to upstream calibration consistency.

0.31