CS Paper Radar

A Strong Linear Baseline for Whole-Heart Cardiac Shape Completion on CT, with an Open Eleven-Structure Statistical Shape Model

Matej Gazda, Jakub Gazda, Juraj Gazda, Peter Drotar

cs.AI ·submitted 2026-08-20 11:45 UTC · v1
publishedbenchmark

Abstract

Public cardiac cohorts annotate different subsets of the heart, so shapes from separate sources cannot be pooled without shared correspondence. Among released cardiac shape resources, none we identified carries the atrial appendage, pulmonary veins, and caval stumps as separate blocks in one mesh. Completion benchmarks also compare deep models against a least-squares projection onto shape modes, not the conditional estimator the same fitted model implies. We release an eleven- structure cardiac computed-tomography (CT) statistical shape model, built from 383 automatically labelled cases in 11 571-vertex correspondence, and compare completion estimators under one frozen internal split and endpoint. On a 76-case internal list held out from fitting, a closed-form conditional-Gaussian estimator reconstructed the missing non-chamber structures at 3.717 mm mean per-vertex error, averaged equally over one, three, five, and nine observed structures. A five-refit mask-conditioned graph variational autoencoder reached 5.248 mm and nearest-neighbour retrieval 8.931 mm. The paired difference was 1.531 mm (95% confidence interval 1.384 to 1.711), and the ordering held in a raw-coordinate sensitivity arm. Expert manual labels exist for 58 external CT cases, but our registered reference is close enough to score only five structures. There the closed-form estimator again had lower average surface distance, 95th-percentile Hausdorff distance, and Chamfer error for both completed atria. On a second public benchmark of 20 cases the reference was close enough for three of four completed structures, and the same ordering held there. Four structures have no expert reference. The released model and its completion operator support cohort-unification research on aligned CT, not clinical use.

Closest papers

Nearest neighbours by meaning across the whole index.

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.65
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51

CNVAE: Anatomically Correct Segmentation via Conditional Generative Modeling

eess.IV ·2026-11-04 ·Freddy Jiang, Loic Le Folgoc, Elsa Angelini
similarity 0.62
Abstract

Supervised deep learning segmentation models, although unparalleled in performance, are not immune to anatomical mistakes. We develop a segmentation-by-generation paradigm extending the Nouveau VAE (NVAE) generative framework for anatomically correct cardiac segmentation. In particular, we propose a novel conditional NVAE model (CNVAE) for conditional shape generation, and explore its capabilities for image segmentation in two scenarios: (1) direct image-to-mask CNVAE for one-step segmentation; (2) mask-to-mask CNVAE for refinement of segmentation masks produced by third-party segmentation models. Both models are lightweight and return consistently anatomically valid segmentation masks (> 98% success rate, an improvement of 15% above state-of-the-art segmentation models) on the cardiac segmentation/editing tasks of interest, without loss of accuracy in segmented contours.

0.25

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.62
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

GLR-MM: Graph-Based Global-Local Reconstruction for Robust Multimodal Chest X-ray and EHR Representation Learning under Missing Modalities

cs.LG cs.AI ·2026-09-20 ·Surbhi Sharma, Nikhil Manali, Devesh Maheshwari
published similarity 0.62
Abstract · Accepted in MICCAI

Clinical multimodal models must often predict before all chest X-ray (CXR) and electronic health record (EHR) inputs are available. Existing approaches align observed representations, model missingness, or reconstruct across modalities, but do not jointly exploit within-patient and clinically similar inter-patient evidence. We propose GLR-MM, a Graph-Based Global-Local Reconstruction framework for early ICU mortality prediction. It maps five CXR-EHR modalities to a shared space, reconstructs missing embeddings through complementary local cross-modal and global graph-attention branches, adaptively fuses their estimates, and optimizes class-balanced prediction, reconstruction, and contrastive objectives. On 9,620 MIMIC-derived ICU stays, we evaluate 10%, 30%, and 50% random modality missingness with shared deterministic masks. MUSE performs better under mild and moderate missingness, whereas GLR-MM achieves higher AUROC and AUPRC at 50% by 0.0088 and 0.0249, respectively. These results indicate that graph-guided reconstruction is most useful when inputs are severely incomplete.

0.24

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.62
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23

MedBOE: Optimization-Based Estimation of Complete Patient Body Models from Whole-Body Medical Imaging

cs.CV ·2026-10-20 ·Hoijoon Jung, Yuhao Wei, Mingxiao Tu, Younhyun Jung, Michael Fulham +1 more
similarity 0.61
Abstract · Hoijoon Jung and Yuhao Wei contributed equally to this work

True whole-body medical imaging captures a patient from head to toe and provides comprehensive anatomical and/or functional information. This coverage enables reconstruction of the external body surface, yielding patient body models. However, scanner geometry (e.g., bore diameter), patient characteristics, and positioning can leave body regions missing (e.g., lateral arms/torso, hands, forearms, elbows), producing incomplete patient body models. Such incompleteness limits downstream medical analyses, including derivation of body-habitus metrics (BHMs), such as body volume and surface area, for injected radiotracer activity regimens, cardiometabolic risk assessment, and computational anatomical modeling for medical imaging simulation and radiation dosimetry. We present the Medical Body model Optimization-based Estimator (MedBOE), an automated, training-free framework for estimating complete patient body models from whole-body images with missing body regions. Our innovation is to leverage the Skinned Multi-Person Linear (SMPL) template, a parametric body mesh representing a broad range of body shapes and poses, in medical imaging. MedBOE aligns the SMPL template to the incomplete patient body models via attribute-guided optimization and estimates missing body regions through geometrically and volumetrically constrained deformation. We evaluated MedBOE using two public datasets: AutoPET (91 whole-body PET-CT images) and Human Implicit Tissues (HIT; 40 whole-body segmentations from MRI images). MedBOE achieved the best overall volumetric and geometric performance among evaluated methods. BHMs derived from MedBOE were within 2% error, suggesting low percentage errors for downstream analyses. MedBOE offers an automated, training-free method for estimating complete patient body models from whole-body images with missing body regions.

0.23

Flow-based conditional cardiac anatomy generation for virtual cohorts

cs.LG cs.CVq-bio.QMq-bio.TO ·2026-08-10 ·Konstantinos Kevopoulos, Beatrice Moscoloni, Benjamin Alheit, Cameron Beeche, Julio A. Chirinos +2 more
similarity 0.60
Abstract

Cardiac digital twin research is moving from subject-specific anatomical replicas toward virtual cohorts that represent clinically relevant population subgroups. Yet access to representative imaging-derived anatomy datasets remains limited by cohort size, subgroup sparsity, and data-sharing constraints. Conditional generative models could help address this gap, but virtual cohorts are useful only if they preserve realistic, metadata-dependent anatomical variability. Existing cardiac anatomy generators largely rely on conditional variational autoencoders (cVAEs), which couple representation learning and metadata conditioning through a shared regularized latent prior. We introduce CAN-FLOW, a two-step Conditional ANatomy generation framework based on normalizing FLOWs that first learns geometry-only latent representations of diffeomorphic cardiac shape momenta and then models their sex-, age-, and body-mass-index-dependent distribution with a conditional normalizing flow. We trained CAN-FLOW on 2,208 healthy UK Biobank subjects and compared it with cVAEs across regularization strengths. CAN-FLOW generated plausible stochastic biventricular anatomies that better reproduced clinical phenotype distributions, metadata-dependent trends, subgroup variability, point-cloud coverage, and high-dimensional shape variability. Together, these results establish CAN-FLOW as a shareable framework for generating realistic, stochastically varying, metadata-conditioned biventricular anatomies for virtual cohort construction and in silico clinical trial workflows.

0.04

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.60
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29