CS Paper Radar

FallGown: A Soft Pneumatic Wearable Device for Fall Prevention

Megan C. Coram, Haoran Lei, Steven H. Collins, Steve B. Cousins, Michelle Baldonado, Cynthia Sung, Allison M. Okamura

cs.RO ·submitted 2026-10-08 20:36 UTC · v2
unusual

Abstract

Concerns about falling and potential resulting injuries prevent many older adults from participating in forms of health-improving exercise such as walking, dance, and tai chi. Existing passive devices like walkers require use of the arms for support, and active devices like exoskeletons and robotic frames are often rigid, bulky, and stigmatized, which limits their use. The FallGown is a soft wearable support structure consisting of pressurized pneumatic pouches within a fabric shell; it can support the full weight of a user's body and aims to prevent falls. It is portable (6.9 kg and 0.051 m3 when stored), minimally burdensome (7.24-20.8 N drag force depending on floor type and whether an optional rolling base frame is used), and convenient (less than 2.5 minutes on average to don and less than 0.5 minutes on average to doff). The optional rolling base lowers friction with the floor, but reduces portability and skirt deformation (which can be useful to fit through doors and other tight spaces). Fall prevention testing with a single user revealed a tradeoff between device size and stability against tipping; a skirt with 12 pneumatic pouches and a floor diameter of 1.4 meters with a base frame prevented all falls except in one case with a mechanical failure. On-board pressure sensors can sense the user's weight distribution, providing an opportunity for monitored exercise and adaptive support.

Closest papers

Nearest neighbours by meaning across the whole index.

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

cs.RO ·2026-11-03 ·Sherry Choi, Sitao Sunny Li, Joseph Romero, Lillian Chin, Ashwin G. Ramayya +2 more
benchmark similarity 0.50
Abstract · 8 pages, 7 figures. Supplementary video in ancillary files. Sherry Choi and Sitao Sunny Li contributed equally to this work

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

0.25

Hugging Suit: Pneumatically-Actuated System Design for Remote Haptic Experiences

cs.HC cs.ET ·2026-10-06 ·Russian, Wu, Luke Hespanhol, Marius Hoggenmueller, Hannes Waldschütz +1 more
published similarity 0.49
Abstract · Accepted Work in Progress at the IEEE World Haptics Conference 2025, July 8-11, 2025, Suwon, South Korea. 2 pages, 1 figure

The COVID-19 pandemic emphasised the importance of remote emotional communication and highlighted a gap in existing technologies that lack haptic channels. While video calls maintain visual and auditory presence, they cannot convey the emotional depth of physical contact, especially hugging, a universally recognised form of intimacy and support. To explore this challenge, we developed the Hugging Suit, a pneumatically-actuated wearable system that enables users to simulate and receive remote hugs in real time. Unlike prior haptic systems that focus solely on tactile sensation, our approach integrates both technical and experiential considerations. The system integrates a programmable Air Actuator Matrix (AAM), a portable high-pressure pneumatic unit, and a fabric-based pressure sensor layer, enabling precise, wearable haptic feedback while remaining lightweight and mobile. Guided by a Research through Design (RtD) methodology, we iteratively refined the prototype to improve tactile resolution, overall usability, and user comfort, while introducing modular components to support flexible and scalable haptic configurations. In parallel, we explored how specific contextual factors, such as lighting, privacy, and the visibility of the remote partner, might shape the emotional and perceptual experience of receiving a remote hug. Preliminary feedback suggests that low-lit, private spaces, especially when users could also see their remote partner via video, improved emotional engagement and comfort during mediated haptic experiences. Our low-cost, maker-space-friendly approach contributes to affective haptics applications in long-distance relationships, emotional regulation, and remote therapeutic support.

0.29

SmartFlex: An Adaptive Lumbar Support System Based on Posture Recognition and Air Bag Array

cs.HC ·2026-09-16 ·Ben Xiaolu Huang
similarity 0.47
Abstract · 4 pages, 5 figures, Accepted for publication in the Companion of the 2026 ACM International Joint Conference on Pervasive and Ubiquitous Com…

Low back pain (LBP) is a leading cause of disability worldwide and affects populations ranging from working adults to students with prolonged sitting habits. Conventional lumbar support belts are generally static and non-adaptive, which limits their ability to accommodate dynamic postural changes and individualized comfort requirements. This paper presents SmartFlex, an intelligent wearable lumbar support system that integrates real-time posture recognition with an adaptive air bag array. The system uses a JY901S gyroscope sensor to detect user posture and a lightweight TinyML neural network deployed on an Arduino R4 UNO to process posture data at the edge. Based on the recognized posture state, a closed-loop pneumatic control system dynamically inflates or deflates 14 distributed air bags through four independent micro air pumps to provide targeted biomechanical support. Evaluation results show that SmartFlex achieves over 94% posture recognition accuracy and generates corresponding pressure-control commands with a sensing-to-command delay of less than 120 ms. The pneumatic system operates within a calibrated pressure range of 15-85 kPa. A user study with 20 participants produced a 4.5/5 rating for support effectiveness, suggesting that adaptive wearable support may improve daily sitting comfort and reduce lumbar fatigue.

0.33

Beyond Simulated Benchmarks: Evaluating Motion Representations for Fall Detection Under Real-World Data Scarcity

cs.LG ·2026-08-13 ·Timilehin B. Aderinola, Ilaria D'Ascanio, Luca Palmerini, Lorenzo Chiari, Jochen Klenk +3 more
similarity 0.47
Abstract

Falls are a major health concern for older adults, and wearable sensors have been widely explored for detecting falls and enabling timely intervention. However, real-world falls are extremely rare: collecting 100 of them requires an estimated 100,000 days of monitoring, resulting in severely limited labelled data for training machine learning models. Consequently, many approaches rely on simulated datasets, often reporting high laboratory performance but limited real-world generalisation. We present a systematic evaluation of motion representations for wearable fall detection under real-world data scarcity. Using accelerometer signals, we compare interval-based, kernel-based, symbolic, and foundation model representations. As an interpretable baseline, we additionally investigate a lightweight symbolic representation that converts short motion segments into symbolic sentences augmented with physically-grounded impact descriptors. Experiments use FallAllD, a simulated falls dataset, and FARSEEING, a clinically verified real-world falls dataset. Through cross-validation, controlled data scarcity, and cross-dataset transfer, we examine how representation choices affect robustness under realistic deployment. Our results reveal that highly parameterised kernel and foundation models excel on simulated data but degrade severely under both data scarcity and domain shift. Although the interval-based representation achieves the strongest absolute real-world performance, augmenting a symbolic representation with physically-grounded impact descriptors yields the smallest degradation under domain shift and retains detection sensitivity under extreme scarcity, albeit at lower precision. These findings highlight the importance of evaluating beyond simulated benchmarks and show that representation choice is critical for deployable fall detection given the scarcity of real-world data.

0.04

A Wearable Pneumatic Device for Continuous, Closed-Loop, Bidirectional Tactile Interaction

cs.RO ·2026-09-01 ·Cosima du Pasquier, Aliyah Smith, Serin Huber, Joshua Phelps, Ilana A. Cohen +3 more
similarity 0.46
Abstract

We present a system of two wearable pneumatic haptic devices that supports continuous, closed-loop, bidirectional tactile interaction at perceptually relevant force and temporal scales. A single device can contain up to twelve pressure sensing channels connected to textile-based pneumatic pouches. Each channel in a device can be used as a sensor, an actuator, or both. As an actuator with integrated sensing, the channel generates stable skin indentation through local closed-loop control. As a sensor, a channel can be mounted (or worn) on any surface, including on a robot gripper or on the human body, and used to measure touch interactions with the environment or a human user. A distributed architecture supports sustained pressure output, rapid dynamic response, and wireless pairing of identical devices in a system to transmit and reproduce tactile pressure signals in real time. Device-level characterization demonstrates force bandwidth exceeding 30 Hz, rapid and well-damped step responses, and extended pressure retention compared to prior compact pneumatic platforms. Human studies show that pressure-based fingertip feedback enables discrimination of force and stiffness, improves teleoperated manipulation by reducing applied pressures by up to 23.1% and task duration by up to 27.4%, and lowers subjective mental workload by 18.8%, particularly under visually constrained conditions. By unifying tactile sensing and haptic feedback within a single pneumatic modality, the device provides a practical foundation for bidirectional touch interaction in teleoperation.

0.14

ShowerFlex: Achieving Pseudo-Static Balancing in a Continuum Shower Hose

cs.RO ·2026-10-01 ·Zhiyu Ren, Girish Krishnan
published similarity 0.45
Abstract · 10 pages, 9 figures. Accepted to ASME IDETC/CIE 2026, Mechanisms and Robotics Conference

With the global population rapidly aging, maintaining independence in Activities of Daily Living (ADLs), particularly bathing or showering, has become a critical challenge. Older adults who sit while showering currently have limited options, often relying on rigid overhead showerheads or flexible hand-held hoses that require continuous gripping and precarious user maneuvers, increasing the risk of falls. To address this need, this paper introduces a highly articulated, pseudo-static balanced continuum mechanism designed specifically for accessible bathing assistance. The proposed mechanism features a modular continuum architecture composed of friction-locked ball-and-socket joints (loc-line), seamlessly integrated with a retractable spring-loaded reel for effective gravity compensation. This hybrid design achieves an intuitive "Push-and-Stay" interaction logic, maintaining an approximate static equilibrium with ergonomically low actuation force, without any external electronic power, while significantly minimizing the force needed for repositioning. Theoretically, we established a recursive forward kinematics framework to construct the geometric model of the structure, coupled with a comprehensive static equilibrium analysis to evaluate the system's holding capacity across its 51-DOF structure. Numerical simulations utilizing Monte Carlo methods validate the system's morphological adaptability and stability at various extreme positions within a standard bath space. Physical experiments further validate the prototype's real-world performance, confirming its intrinsic static stability against gravity and ensuring that the actuation force remains well within the ergonomic capabilities of older adults. Ultimately, this research provides a low-cost, intrinsically safe showerhead design that reduces physical strain, restoring dignity and autonomy in personal hygiene.

0.35

Elbow Angle Guidance System Based on Surface Haptic Sensations Elicited by Lightweight Wearable Fabric Actuator

cs.HC cs.RO ·2026-08-11 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
published similarity 0.45
Abstract · This is the accepted version of the paper published in Proc. 2024 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), …

The demand for wearable haptic devices has rapidly increased for various applications. However, many haptic devices interfere with the wearer's activities and movements. In addition, several haptic devices fail to elicit intuitive haptic sensations by adjusting to the natural posture of the wearer. To address these issues, we propose an elbow angle guidance system using a lightweight wearable fabric actuator. The proposed actuator is made of fabric and has two McKibben-type artificial muscles attached to it, rendering it extremely lightweight and facilitating the delivery of surface haptic sensations to intuitively induce elbow extension and flexion. The surface haptic sensation elicited by the fabric actuator is adjusted to natural body movements without interfering with the wearer's movements. Moreover, the proposed system measures and guides the elbow angle by changing the intensity of the surface haptic sensation delivered to users in real time. The accuracy of the proposed system is demonstrated through experiments involving human participants.

0.65

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

cs.RO ·2026-11-17 ·Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij
similarity 0.45
Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

0.24