CS Paper Radar

SmartFlex: An Adaptive Lumbar Support System Based on Posture Recognition and Air Bag Array

Ben Xiaolu Huang

cs.HC ·submitted 2026-09-16 07:05 UTC · v1

Abstract

Low back pain (LBP) is a leading cause of disability worldwide and affects populations ranging from working adults to students with prolonged sitting habits. Conventional lumbar support belts are generally static and non-adaptive, which limits their ability to accommodate dynamic postural changes and individualized comfort requirements. This paper presents SmartFlex, an intelligent wearable lumbar support system that integrates real-time posture recognition with an adaptive air bag array. The system uses a JY901S gyroscope sensor to detect user posture and a lightweight TinyML neural network deployed on an Arduino R4 UNO to process posture data at the edge. Based on the recognized posture state, a closed-loop pneumatic control system dynamically inflates or deflates 14 distributed air bags through four independent micro air pumps to provide targeted biomechanical support. Evaluation results show that SmartFlex achieves over 94% posture recognition accuracy and generates corresponding pressure-control commands with a sensing-to-command delay of less than 120 ms. The pneumatic system operates within a calibrated pressure range of 15-85 kPa. A user study with 20 participants produced a 4.5/5 rating for support effectiveness, suggesting that adaptive wearable support may improve daily sitting comfort and reduce lumbar fatigue.

Comment
4 pages, 5 figures, Accepted for publication in the Companion of the 2026 ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp Companion '26)
DOI
10.1145/3798063.3837839

Closest papers

Nearest neighbours by meaning across the whole index.

Hugging Suit: Pneumatically-Actuated System Design for Remote Haptic Experiences

cs.HC cs.ET ·2026-10-06 ·Russian, Wu, Luke Hespanhol, Marius Hoggenmueller, Hannes Waldschütz +1 more
published similarity 0.56
Abstract · Accepted Work in Progress at the IEEE World Haptics Conference 2025, July 8-11, 2025, Suwon, South Korea. 2 pages, 1 figure

The COVID-19 pandemic emphasised the importance of remote emotional communication and highlighted a gap in existing technologies that lack haptic channels. While video calls maintain visual and auditory presence, they cannot convey the emotional depth of physical contact, especially hugging, a universally recognised form of intimacy and support. To explore this challenge, we developed the Hugging Suit, a pneumatically-actuated wearable system that enables users to simulate and receive remote hugs in real time. Unlike prior haptic systems that focus solely on tactile sensation, our approach integrates both technical and experiential considerations. The system integrates a programmable Air Actuator Matrix (AAM), a portable high-pressure pneumatic unit, and a fabric-based pressure sensor layer, enabling precise, wearable haptic feedback while remaining lightweight and mobile. Guided by a Research through Design (RtD) methodology, we iteratively refined the prototype to improve tactile resolution, overall usability, and user comfort, while introducing modular components to support flexible and scalable haptic configurations. In parallel, we explored how specific contextual factors, such as lighting, privacy, and the visibility of the remote partner, might shape the emotional and perceptual experience of receiving a remote hug. Preliminary feedback suggests that low-lit, private spaces, especially when users could also see their remote partner via video, improved emotional engagement and comfort during mediated haptic experiences. Our low-cost, maker-space-friendly approach contributes to affective haptics applications in long-distance relationships, emotional regulation, and remote therapeutic support.

0.29

What the Sleeve Feels: Explainable Machine Learning for Textile Pressure-Based Postural Screening

cs.AI ·2026-10-07 ·Limon Bin Hossain, Md Sadib Rahman Ananta
similarity 0.55
Abstract

Pressure-sensing smart textiles convert body-surface contact into a dense, image-like signal closely tied to posture and movement, making them a promising low-cost route to wearable posture screening. Realizing that promise, however, requires more than classification accuracy: a deployable system must generalize to wearers unseen during training, expose the physical evidence behind its decisions, and tolerate the small donning offsets that occur whenever a garment is removed and re-worn. This paper addresses these three requirements jointly using a knitted piezoresistive sleeve worn on the forearm as a testbed. We regroup fine-grained everyday activities into three coarser screening categories (neutral, potentially undesirable, and functional or transitional), engineer 29 interpretable pressure-distribution features spanning global intensity, spatial center of pressure, quadrant asymmetry, distribution complexity, and short-horizon temporal change, and evaluate under a strict subject-wise split. A tuned XGBoost classifier reaches 0.818 accuracy, 0.788 balanced accuracy, and 0.801 macro F1 on unseen test subjects, with tight frame-level bootstrap 95% intervals of about plus-minus 0.01 and a subject-to-subject standard deviation near 0.06 under leave-one-subject-out cross-validation. A simple 2D-CNN baseline trained on raw frames achieves broadly similar performance, showing that hand-engineered features are not left behind by a learned spatial representation on this task. SHAP-based explanation, a feature-group ablation, per-activity error analysis inside the pooled undesirable class, class-mapping sensitivity, and a simulated donning-rotation stress test together locate what the model relies on, where it degrades, and why, directly targeting the generalization, interpretability, and robustness gaps that determine whether such a system is deployable.

0.25

A Wearable Pneumatic Device for Continuous, Closed-Loop, Bidirectional Tactile Interaction

cs.RO ·2026-09-01 ·Cosima du Pasquier, Aliyah Smith, Serin Huber, Joshua Phelps, Ilana A. Cohen +3 more
similarity 0.55
Abstract

We present a system of two wearable pneumatic haptic devices that supports continuous, closed-loop, bidirectional tactile interaction at perceptually relevant force and temporal scales. A single device can contain up to twelve pressure sensing channels connected to textile-based pneumatic pouches. Each channel in a device can be used as a sensor, an actuator, or both. As an actuator with integrated sensing, the channel generates stable skin indentation through local closed-loop control. As a sensor, a channel can be mounted (or worn) on any surface, including on a robot gripper or on the human body, and used to measure touch interactions with the environment or a human user. A distributed architecture supports sustained pressure output, rapid dynamic response, and wireless pairing of identical devices in a system to transmit and reproduce tactile pressure signals in real time. Device-level characterization demonstrates force bandwidth exceeding 30 Hz, rapid and well-damped step responses, and extended pressure retention compared to prior compact pneumatic platforms. Human studies show that pressure-based fingertip feedback enables discrimination of force and stiffness, improves teleoperated manipulation by reducing applied pressures by up to 23.1% and task duration by up to 27.4%, and lowers subjective mental workload by 18.8%, particularly under visually constrained conditions. By unifying tactile sensing and haptic feedback within a single pneumatic modality, the device provides a practical foundation for bidirectional touch interaction in teleoperation.

0.14

Intuitive Directional Sense Presentation to the Torso Using McKibben-Based Surface Haptic Sensation in Immersive Space

cs.HC cs.RO ·2026-08-10 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
top venue similarity 0.55
Abstract · This is the accepted version of an article published in IEEE Transactions on Haptics 18(1), 244-254 (2025). DOI: 10.1109/TOH.2024.3522897. O…

In recent years, systems that utilize immersive space have been developed in various fields. Immersive spaces often contain considerable amounts of visual information; therefore, users often fail to obtain their desired information. Therefore, various methods have been developed to guide users toward haptic sensations. However, many of these methods have limitations in terms of the intuitive perception of haptic sensation and require practice for familiarization with haptic sensation. Fabric actuators are wearable haptic devices that combine fabric and McKibben artificial muscles to provide wearers with surface haptic sensation. These sensations can be provided to a wide area of the body with intuitive perception, instead of only to a part of the body. This paper presents a novel air pressure adjustment method for whole-body motion guidance using surface haptic sensations provided by a wearable fabric actuator. The proposed system can provide users with a directional sense without visual information in an immersive space. The effectiveness of the proposed system was evaluated through subject experiments and statistical data analysis. Finally, a directional sense presentation was conducted for users performing micromanipulations in a mixed-reality space to demonstrate the applicability of the proposed system for teleoperation.

0.73

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

cs.RO ·2026-11-17 ·Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij
similarity 0.53
Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

0.24

MiBOT: A head-worn robot that modulates cardiovascular responses through human-like soft massage

cs.RO eess.SY ·2026-08-30 ·Alice Mylaeus, Stephanie Vogt, Berken Utku Demirel, Marcel Gort, Mirko Meboldt +2 more
top venue similarity 0.52
Abstract · Published at 2024 IEEE International Conference on Robotics and Automation (ICRA)

Massage therapy is helpful for the rehabilitation of various diseases, such as headaches caused by migraines and stress. Existing robotic systems have focused on massage therapy on the torso and limbs, but performing massage motions through suitable actuation on a person's head has been a challenge. In this paper, we present MiBOT, a head-worn massage robot that actuates two soft tactors to produce touch motions mimicking human massage. A key design principle behind MiBOT is its silent actuation, which we achieve through pneumatic artificial muscles in conjunction with a controller loop to respond to contact pressure. We evaluated the effectiveness of MiBOT in a controlled study and assessed subjects' blood pressure and heart rate levels while applying MiBOT. We found that our mechanical system generated positive and conclusive quantitative outcomes that are similar to the human-administered massage, decreasing participants' mean systolic and diastolic blood pressure by 2.8 mmHg and 1.7 mmHg, respectively, as well as calming their heart rate by 8-10% on average.

0.41

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

cs.SD ·2026-10-27 ·Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan +3 more
similarity 0.52
Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

0.21

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

cs.RO ·2026-11-03 ·Sherry Choi, Sitao Sunny Li, Joseph Romero, Lillian Chin, Ashwin G. Ramayya +2 more
benchmark similarity 0.51
Abstract · 8 pages, 7 figures. Supplementary video in ancillary files. Sherry Choi and Sitao Sunny Li contributed equally to this work

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

0.25