CS Paper Radar

FreeBrush: Motor Signals-Based Toothbrushing Monitoring System for Electric Toothbrushes

Pinhao Lin, Xuanyu Liu, Guoheng Ma, Haoxian Liu, Zongqi Yang, Jin Zhang

cs.HC ·submitted 2026-10-11 17:43 UTC · v1
unusual

Abstract

Oral health is vital for overall well-being, yet many users brush different tooth surfaces for insufficient or excessive durations. Toothbrushing monitoring systems can help improve brushing habits by reminding users of under-brushed and over-brushed surfaces, but existing approaches often rely on external sensors, increasing cost and reducing practicality. We observe that the intrinsic motor signals of electric toothbrushes can reflect the brushing surfaces and durations. When brushing different tooth surfaces, the brush head experiences different constraints from the surrounding oral cavity, changing the motor's driving currents and position feedback. Based on this observation, we propose FreeBrush, a toothbrushing monitoring system that uses the intrinsic motor signals of electric toothbrushes to recognize brushed tooth surfaces and estimate brushing durations without any external sensors. We prototype the system on a commercial off-the-shelf electric toothbrush and conduct a comprehensive evaluation with 18 participants. FreeBrush achieves 92.8% accuracy for 16-surface recognition and 92.0% accuracy for brushing duration estimation. The system further shows robustness across different toothpastes, brush heads, vibration modes, usage scenarios, and long-term use, and is capable of running on edge devices. By recognizing brushed tooth surfaces and estimating the brushing duration, FreeBrush can help users identify under-brushed and over-brushed surfaces and build balanced brushing habits.

Comment
15 pages. Includes a 2-page supplementary document as an ancillary file. Extended version of our workshop paper "BrushSense: Toothbrushing Region Recognition Using Motor Signals" (UbiSense 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

TapID: Rapid touch interaction in virtual reality using wearable sensing

cs.HC eess.SP ·2026-10-19 ·Manuel Meier, Paul Streli, Andreas Fender, Christian Holz
top venuepositionhighly cited similarity 0.50
Abstract · accepted to IEEE VR 2021

Current Virtual Reality systems typically use cameras to capture user input from controllers or free-hand mid-air interaction. In this paper, we argue that this is a key impediment to productivity scenarios in VR, which require continued interaction over prolonged periods of time---a requirement that controller or free-hand input in mid-air does not satisfy. To address this challenge, we bring rapid touch interaction on surfaces to Virtual Reality---the input modality that users have grown used to on phones and tablets for continued use. We present TapID, a wrist-based inertial sensing system that complements headset-tracked hand poses to trigger input in VR. TapID embeds a pair of inertial sensors in a flexible strap, one at either side of the wrist; from the combination of registered signals, TapID reliably detects surface touch events and, more importantly, identifies the finger used for touch. We evaluated TapID in a series of userstudies on event-detection accuracy (F1 = 0.997) and hand-agnostic finger-identification accuracy (within-user: F1 = 0.93; across users: F1 = 0.91 after 10 refinement taps and F1 = 0.87 without refinement) in a seated table scenario. We conclude with a series of applications that complement hand tracking with touch input and that are uniquely enabled by TapID, including UI control, rapid keyboard typing and piano playing, as well as surface gestures.

0.63

PalmSpace: Towards a Versatile On-Palm Interaction Space through Unified Touch Modeling

cs.HC cs.CV ·2026-10-07 ·Chentao Li, Mingze Gao, Runze Sun, Zhaoguo Wang, Jianjiang Feng +1 more
similarity 0.50
Abstract · Preprint. Initial version

As smart glasses and lightweight MR devices become increasingly practical, input remains a key challenge. The bare palm is an always-available, tactile, and proprioceptively accessible surface, but it has neither an explicit coordinate system nor embedded touch sensing. Prior on-palm systems typically expose isolated touch events, discrete regions, continuous trajectories, or task-specific gestures, limiting the palm's ability to support precise selection and gesture manipulation through a common input representation. We present PalmSpace, a wrist-worn infrared system that exposes mode-aware, body-referenced absolute input on the bare palm without per-user sensing calibration. At the interaction level, PalmSpace jointly represents contact occurrence, interaction mode, and palm-referenced absolute location; at the model level, it learns these coupled outputs through a shared real-time representation. In leave-one-participant-out evaluation with 17 participants, PalmSpace achieved 6.7 mm mean localization error, 98.9% contact detection accuracy, and 96.7% F1 for four-class interaction-state recognition. User studies further demonstrated absolute pointing and dragging, eyes-free digit input, and representative multi-finger controls including scrolling and pinch-based map manipulation. These results show that a morphologically variable bare palm can function as a transferable, mode-aware interaction surface.

0.17

EITWatch: Smartwatch-Integrated Planar Electrical Impedance Tomography for Hand Gesture Recognition

cs.HC ·2026-08-29 ·Xuanyou Liu, Novel Alam, Karan Ahuja
top venuecode/data similarity 0.50
Abstract · 7 pages, 6 figures, 2 tables. Accepted to UIST '26. Code: https://github.com/XuanyouLiu/EITWatch_Hardware

Wrist Electrical Impedance Tomography (EIT) senses hand gestures from muscle- and tendon-driven impedance changes, but prior wrist-EIT systems require electrode coverage beyond the watch-back contact patch and separate analog front ends. We present EITWatch, the first wrist-EIT system built around smartwatch case-back geometry, asking whether this contact patch alone can support gesture recognition: eight planar electrodes in a 31 mm ring acquire 35 impedance measurements at 48 Hz. Because a planar array cannot encircle the wrist, EITWatch uses multi-depth scanning to sample multiple source-sink distances and current paths; it beat matched adjacent injection by 15.1/10.4 percentage points (macro/micro) across all 12 participants. In a prompted study, within-session leave-one-round-out accuracy reached 91.4%/92.5% (window/trial) for six macro-gestures, and 90.1%/91.5% (window/segment) for five micro-gestures plus relax; window-level cross-session and leave-one-user-out transfer reached 73.2%/70.4% and 63.1%/55.3% (macro/micro).

0.58

TableControl: Gesture Interaction Through Surface Vibrations

cs.HC cs.LG ·2026-11-18 ·Florian Hettstedt, Andreas Erbslöh, Gregor Schiele
published similarity 0.48
Abstract · 4 pages, 3 figures, accepted as demo paper on the ACM ISS

Integrating gesture sensing into furniture offers a way to interact with digital applications and physical devices through familiar surfaces. We present TableControl, an interactive demonstration of continuous surface-vibration-based gesture recognition with the complete processing pipeline running on a microcontroller. Using four concealed piezoelectric sensors, the system combines signal acquisition and preprocessing with neural event detection and gesture classification. The resulting labels for knock, swipe-up, and swipe-down gestures are transmitted to a host computer without streaming the underlying sensor signals. Visitors explore two example applications through hands-on interaction: an endless runner game and a physical table lamp with on/off and brightness control. A dashboard displays recognized gestures, class probabilities, and processing times.

0.42

Wearable Multimodal Human-Machine Interface for Integrated Hand Intentions Decoding in Dynamic Teleoperation

cs.RO ·2026-09-07 ·Jiaxuan Li, Yinshi Wu, Xiao Zhang, Hongyu Wang, Renzhen Le +2 more
similarity 0.48
Abstract

Under ubiquitous teleoperation environments with optically challenging conditions, an interface for tele-operated grasping that combines wearability with precise decoding of hand intentions (hand pose, gestures, and grasping force) is essential. Yet, existing interfaces often fall short in meeting these demands, compromising either the diversity of multiple intentions decoding or wearability. To address this, we developed a novel Multiple Intentions Decoding Human-Machine Interface (MI-DHMI) that integrates high-throughput surface electromyography (sEMG) sensors with hand-mounted and forearm-mounted inertial measurement units (IMUs). The developed interface is supported by a unified framework for simultaneous multiple intentions decoding. By employing multimodal deep learning and hardware design with a low noise floor, the decoding framework selectively focuses on the sEMG components that are genuinely associated with finger movements. This effectively reduces decoding errors caused by sEMG variability during unconstrained upper-limb motions, thereby significantly enhancing robustness. Even under unconstrained wrist and forearm motion, the interface achieves a gesture recognition accuracy exceeding 97%, grasping force estimation with $R^2 = 0.95$, and hand pose decoding consistent with the actual hand pose, outperforming baseline devices and algorithms. Ablation studies further validate the effectiveness of the proposed decoding framework. Finally, two online experiments were conducted to validate the device, demonstrating its superior performance in high-stability tasks, including a pouring task and object grasping. The developed interface provides a new solution of a fully wearable, multiple intentions decoding system, offering effective support for ubiquitous teleoperation and contributing to the advancement of human-machine interaction research.

0.27

Data-Centric Neuromotor Interfaces for Portable Human-Machine Interaction

cs.RO ·2026-08-31 ·Jiaxuan Li, Di Wu, Jianhua Liu, Yuxin Zhao, Jinnuo Li +5 more
publishedbenchmark similarity 0.47
Abstract

Dexterous human-machine interaction requires intuitive and expressive interfaces that can be efficiently deployed on constrained edge devices. Flexible material-based neuromotor interfaces hold considerable promise, as they decode human movement intention into natural control. Although emerging flexible electronic skins enable wearable high-fidelity data acquisition, practical deployment inevitably involves trade-offs between computational resources and portability. We present a data-centric paradigm where physiological features yield fundamental separability, providing sufficient discriminative cues for recognition. A wireless, high-bandwidth system developed for collecting various electrophysiological signals, when integrated with muscle-specific electrodes, forms a surface electromyography-based interface. Exploiting highly separable data, a 2,210-parameter model achieves 94.36% accuracy across 34 gestures and can be rapidly deployed on edge devices, establishing a new thousand-parameter benchmark for dexterous decoding. The underlying data-algorithm interactions in the data-centric paradigm are further clarified, demonstrating its feasibility in real-world scenarios. This study provides a principled and validated pathway for practical deployment of reliable neuromotor interfaces.

0.22

EventHOI: Event-Driven Resource-Efficient Hand-Object Interaction Logging on Smartglasses

cs.DC cs.CVcs.HC ·2026-11-06 ·Le Zhang, Kailai Cui, Hao Chen, Vlad Roznyatovskiy, Jianzhong Zhang +3 more
benchmark similarity 0.47
Abstract · 15 pages, 21 figures, 3 tables

Hand-object interactions (HOIs) can be captured by smartglasses to learn how people manipulate objects in daily life. Automatic logging of these interactions from an egocentric perspective provides time-stamped evidence of daily actions for applications like memory assistance. However, continuous RGB capture and wireless transmission exceed the energy and bandwidth budgets of smartglasses. We present EventHOI, an event-driven sensing and compression system that couples selective RGB capture with HOI-aware encoding to enable egocentric logging over Bluetooth Low Energy (BLE) while preserving downstream HOI logging performance. Our key insight is to use low-power event sensing both to determine when RGB capture is needed and to identify where visual detail must be preserved. A lightweight IMU-based egomotion cancellation pipeline suppresses egomotion-induced events so that residual HOI motion can guide RGB triggering and spatial compression. We build a smartglasses prototype and conduct an end-to-end evaluation of EventHOI on a 50-hour egocentric benchmark with 97 subjects and a 20-hour real-world dataset we collect from 10 participants, together covering a broad range of daily-life scenarios and environments. Compared to RGB-only baselines, EventHOI reduces always-on backend power consumption by 5.8-10.4x and uplink bandwidth by 2.9x, with minimal HOI recognition accuracy loss. The resulting RGB uplink of less than 130 kbps fits within commodity BLE bandwidth budgets, making stable BLE video streaming feasible for egocentric HOI logging. Demo video and project website: https://eventhoi.github.io

0.35

OpenZilo: An Open Smart-Ring Platform for Human-Centric Sensing and Interaction with Robots

cs.RO cs.HC ·2026-11-02 ·Qianggang Ding, Xingyao Wang, Rui Feng, Chi Qin, Weijian Lin +5 more
similarity 0.46
Abstract · 17 pages, 5 figures, 8 tables

Wearable robot interfaces must connect user input to timely physical action. We present the proposed platform, an open smart-ring platform for studying this connection across task stages. The ring integrates a microphone, an inertial measurement unit, photoplethysmography, and skin-temperature sensing. Its software architecture separates acquisition, event interpretation, interaction policy, and robot execution. We characterize seven operating modes and evaluate speech and gesture control with 10 participants. Across five commands and 250 trials per modality, speech and gestures achieved task success rates of 90.4% and 88.8%, respectively. Recognition accuracy exceeded task success for both modalities. Gaussian hidden Markov models achieved higher accuracy than a support vector machine across three vocabulary sizes, with longer scoring times. Following a shared spoken task start, gesture-based adjustments had shorter median response times than speech. Whole-task success was 70.0% with gestures and 64.0% with speech. We further examine physiological-event-triggered robot interaction using simulated event notifications. Mean notification-receipt-to-arrival times were 11.71 s for the robot and 9.20 s for an on-site person. These descriptive findings support evaluating wearable robot interfaces through both recognition and physical outcomes, with timing measures appropriate to each task stage.

0.32