Constrained Grid-Forming Control for Photovoltaic Systems: A Control Barrier Function Approach

Amir Afshari, Dominic Groß

eess.SY ·submitted 2026-10-13 02:27 UTC · v1

Abstract

This paper leverages control barrier functions (CBFs) to systematically account for constraints of voltage source converters (VSCs) and photovoltaic (PV) resources in grid-forming (GFM) control. The proposed control combines (unconstrained) dual-port GFM control with control barrier functions (CBFs) to ensure reliable and safe operation of a GFM PV system under grid faults, sudden changes in irradiance, and load perturbations. First, CBFs are used to encode physical and operational limits of the PV system, namely current and voltage limits at its ac and dc terminals. Then, CBFs are used to restrict the dynamics of dual-port GFM control to within the VSC and PV limits during both transient and steady states. To this end, a cost function is defined that encodes trade-offs between forming the ac voltage phase angle/frequency and voltage magnitude under constraints. Then, real-time optimization is used to make the least modification, as measured by the cost function, to the (unconstrained) dual-port GFM control state to remain within the safe set encoded by the CBFs. Finally, the performance of the developed constrained GFM control is evaluated through EMT simulations in MATLAB/Simulink.

Closest papers

Nearest neighbours by meaning across the whole index.

Safe Barrier Function Control for Grid-Following Inverters under Weak Grid Conditions

eess.SY ·2026-10-18 ·Grigoris Michos, Christos K. Verginis
similarity 0.61
Abstract · 10 pages

This paper proposes a barrier control approach for the safe regulation of grid-following voltage-source-converters (VSC), operating in weak grid conditions. The proposed controller aims to enhance the transient performance and synchronization properties of the VSC, providing frequency and current limiting guarantees by employing smooth control barrier functions. First, a dynamic model is derived that includes the dynamic state interactions that are omitted in quasi-steady-state approaches, revealing the destabilizing elements both during transient and steady-state performance. Then, it is analytically proven that the proposed control law guarantees frequency limitation and inner current evolution in prescribed safety regions, while counteracting the destabilizing strong coupling between PCC voltage and injected current. In addition, sufficient conditions are formulated that guarantee the stability of the closed-loop system with respect to desired operating points. The theoretic results are verified in simulations of case studies operating in varying grid strength.

0.32

Barrier Function Control for the Interconnection of DC Electronic Loads to Utility Grid

eess.SY ·2026-10-22 ·Grigoris Michos, Christos K. Verginis
similarity 0.59
Abstract · preprint for paper to appear in IEEE ISGT Europe conference 2026

This paper proposes a nonlinear control law that facilitates the safe integration of DC electronic loads to the utility grid. Specifically, by employing suitable reciprocal barrier functions, it is rigorously proven that the closed-loop system guarantees constrained operation within a desired operating region, despite the influence of fast converter dynamics and fluctuating constant power load demand. This way, the proposed controller guarantees safety of the electronic components from surges in power demand and high transients. The theoretic results are validated in simulation scenarios, where the performance of the proposed controller is compared against the conventional saturated-PI controller. Contrary to the latter, the proposed method guarantees stable and safe operation, enhancing the system robustness.

0.16

GFM Control Automatic Compliance Toolbox

eess.SY ·2026-11-08 ·Tejas Kunbi, Rahul Rane, Dan Wu, Aleksandra Lekić
similarity 0.58
Abstract

The increasing penetration of converter-interfaced generation reduces system inertia, short-circuit strength, and voltage support. European grid codes, including the ENTSO-E Network Code on Requirements for Generators and the ACER Demand Connection Code, now define disturbance-based validation procedures for grid-forming (GFM) generation and converter-based demand. Commercial RMS tools, however, lack an integrated workflow aligned with these recent requirements. This paper presents an automated Python-PowerFactory compliance toolbox and an RMS test bench for a co-located system comprising a 1 MW GFM photovoltaic (PV) plant, a 0.3 MW GFM battery energy storage system (BESS), and a 1 MW converter-interfaced dynamic load at a 20 kV point of common coupling fed from a 110 kV grid. Extended virtual synchronous machine models and a DCC-oriented load model are tested in batch, with results automatically extracted and plotted for assessment. Results show compliant RMS performance for the slower, electromechanical tests, while the paper identifies which tests require complementary electromagnetic transient (EMT) verification.

0.34

Resource-Aware Rolling-Horizon Controller for Renewable-Based Virtual Power Plants Providing Automatic Frequency Restoration Reserves

eess.SY ·2026-09-25 ·Marco Vinicio Avendaño-Caiza, Juan Diego Rios-Peñaloza, Javier Roldán-Pérez, José Luis Rodríguez-Amenedo, Milan Prodanovic
similarity 0.57
Abstract · Submitted to a scientific journal for possible publication. 10 pages, 11 figures

Virtual power plants (VPPs) are an effective solution for increasing the penetration of renewable energy sources (RES) in power systems. Moreover, VPPs can provide ancillary services if generators and loads are closely connected and properly coordinated. This aspect has been addressed in several studies, yet they mostly focus on the dispatch optimisation level, leaving real-time operation aspects unresolved. To close this gap, a central controller for VPPs based on a rolling-horizon optimisation is proposed in this work. Its main objective is to maximise revenues while delivering frequency restoration services. A day-ahead optimisation firstly defines the power setpoint and the upward and downward reserves of the VPP. Then, the rolling-horizon optimiser, executed every minute, distributes the power and reserve references between the VPP units to achieve their close tracking while taking into account resource availability (wind speed, irradiance, etc.), operational constraints and battery degradation. The effectiveness of the controller is tested using a two-area interconnected power system under different RES generation and demand profiles. The simulations are performed in MATLAB/Simulink and include detailed dynamic models of the VPP elements, demonstrating the applicability of the algorithm to real systems. The day-ahead and the rolling-horizon optimisation problems are modelled using YALMIP and solved using Gurobi. The obtained results demonstrate the VPP supporting grid frequency restoration by optimally allocating its resources, even under the presence of forecast uncertainty.

0.18

Internal-Model-Control-Based Virtual Admittance Emulation for Enhanced Grid-Forming Performance

eess.SY ·2026-09-18 ·Ruzica Cvetanovic, Lazar Stojanovic, Paolo Sbabo, Paolo Mattavelli, Massimo Bongiorno
similarity 0.56
Abstract

The large-scale integration of renewable energy into electrical power systems places a growing reliance on grid-forming converters (GFMs) to overcome critical stability and control hurdles. By emulating a slowly varying voltage source behind a tunable resistive?inductive impedance, GFMs enable precise setpoint tracking and vital grid support. In this regard, virtual admittance (VA)-based inner-loop control provides exceptional flexibility in shaping the converter's small-signal immittance at connection terminals, allowing for advanced GFM functionalities. This article addresses a novel internal-model-control-based VA approach, which inherently accounts for the effects of the inner current-control loop and the voltage feedforward. Unlike the state-of-the-art VA control, the proposed VA control ensures that, at frequencies outside the influence of outer loops, the converter's terminal admittance closely matches the target admittance, which is shown to be relevant for stability. It is revealed how, with the state-of-the art VA control, a small-signal instability in the harmonic range may arise if a low-pass filter with a high cut-off frequency is used for the voltage feedforward. However, the proposed VA control ensures stable operation regardless of this cut-off frequency. The methodology is experimentally validated using a laboratory prototype that features three-phase voltage-source converters.

0.21

Optimal Power Sharing for Hybrid Energy Storage Systems Based on Karush-Kuhn-Tucker Conditions

eess.SY ·2026-09-25 ·Juan Diego Rios-Peñaloza, Milan Prodanovic, Javier Roldán-Pérez
similarity 0.56
Abstract · Submitted to a scientific journal for possible publication. 10 pages, 15 figures

Renewable energy power plants are increasingly expected to provide ancillary services to the grid. Yet, the variability of sources such as solar photovoltaics requires additional operational flexibility to deliver these services. In this context, hybrid energy storage systems (HESSs) offer an appropriate solution, because different technologies with complementary characteristics can be applied and leveraged to share the power demand and improve the overall performance. Yet, a proper power sharing requires a detailed model of the storage elements. This aspect has barely been studied in the literature, where most models consider constant efficiencies. Moreover, most formulations are based on optimisation problems that are computationally too demanding to be solved in real time. In this paper, a controller is proposed to minimise the losses of a HESS considering detailed power-dependent efficiency curves of each storage technology. The power sharing method is based on the analytical verification of the Karush-Kuhn-Tucker (KKT) conditions, which makes it computationally efficient and suitable for real-world deployment. The proposed controller is applied to a test case consisting of a 10 MW PV power plant with a HESS based on a lithium-ion battery and a redox-flow battery, each with 2.5 MW power and 5 MWh capacity. The main contributions are verified via numerical simulations performed in MATLAB/Simulink, whereas a real-time implementation deployed in OPAL-RT demonstrates the viability of the algorithm for real-time applications.

0.29

Headroom-Aware Stochastic Adaptive Model Predictive Control for Load Frequency Control in Microgrids

eess.SY ·2026-09-04 ·Erfan Mehdipour Abadi, Shuo Yuan, Le Yi Wang, Caisheng Wang, Feng Lin
similarity 0.56
Abstract

As the penetration of inverter-based resources (IBRs) increases in microgrids, they are increasingly expected to play a greater role in load frequency control (LFC). Model predictive control (MPC) is attractive for LFC because it incorporates system dynamics and operational constraints. However, most MPC-based LFC formulations rely on fixed reserve headroom based on forecasted renewable availability or storage systems. Under short-term renewable intermittency, IBR headroom is stochastic and time-varying, causing optimal control commands to exceed the physically deliverable regulation capability and cause stochastic saturation. This control-actuator mismatch degrades LFC performance. Accordingly, this study develops two headroom-aware strategies for PV-dominated microgrids. First, stochastic headroom constrained MPC (SHCMPC) incorporates headroom predictions through time-varying input constraints to enforce control feasibility. Second, stochastic adaptive MPC (SAMPC) embeds headroom awareness into the MPC objective function by adaptively penalizing control actions based on predicted headroom, reducing reliance on units with limited headroom without hard time-varying constraints. Simulation results show that stochastic saturation degrades conventional MPC-based LFC, particularly under tight reserve margins. Both strategies improve regulation performance. SHCMPC eliminates saturation events, while SAMPC achieves substantial saturation mitigation with lower computational effort, offering a computationally efficient alternative for real-time LFC under stochastic renewable availability.

0.22

Battery Energy Storage Sizing in PV Ramp-Rate Smoothing using Constraint-Aware Reinforcement Learning-Based Controller

eess.SY ·2026-11-13 ·Arash Omidi, Tanmay Mishra, Mads R. Almassalkhi
benchmark similarity 0.55
Abstract

This paper presents a constraint-aware reinforcement learning (CARL) controller for battery energy storage system (BESS) sizing and photovoltaic (PV) ramp-rate smoothing. Rapid PV power fluctuations caused by cloud transitions can introduce operational and stability challenges in power systems. To mitigate these impacts, grid codes impose ramp-rate limits (RRL) on PV power injected to the grid. BESSs can support such grid codes by absorbing or supplying power during rapid variations. However, the extent to which BESSs can reduce PV-induced variability depends on (i) the BESS power and energy capacities; and (ii) the adopted controller. Thus, BESS sizing and controller design are coupled. Conventional moving-average control can increase battery usage due to filter-induced lag, while ramp-rate control is reactive and does not account for the long-term impact of actions on battery state of charge and future ramp events. Optimization-based methods can reduce BESS requirements by anticipating future PV variations, but their performance depends on accurate PV forecasts. To address these limitations, the CARL controller learns a causal state-feedback policy from historical PV data without requiring forecasts during deployment. Ramp-rate, converter-power, and state-of-charge constraints are incorporated into a causal feasibility interval that guarantees feasible actions by definition. A full-horizon input-convex neural network (ICNN)-based optimization is developed as a noncausal benchmark for the minimum achievable BESS requirements. Evaluation using three real-world PV datasets shows that, at a 10\%/min ramp-rate limit, CARL reduces peak BESS power by 8.7--10.4\% and energy capacity by 47.5--62.6\% relative to conventional ramp-rate control while maintaining the grid-codes compliance.

0.26