CS Paper Radar

Headroom-Aware Stochastic Adaptive Model Predictive Control for Load Frequency Control in Microgrids

Erfan Mehdipour Abadi, Shuo Yuan, Le Yi Wang, Caisheng Wang, Feng Lin

eess.SY ·submitted 2026-09-04 16:36 UTC · v1

Abstract

As the penetration of inverter-based resources (IBRs) increases in microgrids, they are increasingly expected to play a greater role in load frequency control (LFC). Model predictive control (MPC) is attractive for LFC because it incorporates system dynamics and operational constraints. However, most MPC-based LFC formulations rely on fixed reserve headroom based on forecasted renewable availability or storage systems. Under short-term renewable intermittency, IBR headroom is stochastic and time-varying, causing optimal control commands to exceed the physically deliverable regulation capability and cause stochastic saturation. This control-actuator mismatch degrades LFC performance. Accordingly, this study develops two headroom-aware strategies for PV-dominated microgrids. First, stochastic headroom constrained MPC (SHCMPC) incorporates headroom predictions through time-varying input constraints to enforce control feasibility. Second, stochastic adaptive MPC (SAMPC) embeds headroom awareness into the MPC objective function by adaptively penalizing control actions based on predicted headroom, reducing reliance on units with limited headroom without hard time-varying constraints. Simulation results show that stochastic saturation degrades conventional MPC-based LFC, particularly under tight reserve margins. Both strategies improve regulation performance. SHCMPC eliminates saturation events, while SAMPC achieves substantial saturation mitigation with lower computational effort, offering a computationally efficient alternative for real-time LFC under stochastic renewable availability.

Closest papers

Nearest neighbours by meaning across the whole index.

Battery Energy Storage Sizing in PV Ramp-Rate Smoothing using Constraint-Aware Reinforcement Learning-Based Controller

eess.SY ·2026-11-13 ·Arash Omidi, Tanmay Mishra, Mads R. Almassalkhi
benchmark similarity 0.63
Abstract

This paper presents a constraint-aware reinforcement learning (CARL) controller for battery energy storage system (BESS) sizing and photovoltaic (PV) ramp-rate smoothing. Rapid PV power fluctuations caused by cloud transitions can introduce operational and stability challenges in power systems. To mitigate these impacts, grid codes impose ramp-rate limits (RRL) on PV power injected to the grid. BESSs can support such grid codes by absorbing or supplying power during rapid variations. However, the extent to which BESSs can reduce PV-induced variability depends on (i) the BESS power and energy capacities; and (ii) the adopted controller. Thus, BESS sizing and controller design are coupled. Conventional moving-average control can increase battery usage due to filter-induced lag, while ramp-rate control is reactive and does not account for the long-term impact of actions on battery state of charge and future ramp events. Optimization-based methods can reduce BESS requirements by anticipating future PV variations, but their performance depends on accurate PV forecasts. To address these limitations, the CARL controller learns a causal state-feedback policy from historical PV data without requiring forecasts during deployment. Ramp-rate, converter-power, and state-of-charge constraints are incorporated into a causal feasibility interval that guarantees feasible actions by definition. A full-horizon input-convex neural network (ICNN)-based optimization is developed as a noncausal benchmark for the minimum achievable BESS requirements. Evaluation using three real-world PV datasets shows that, at a 10\%/min ramp-rate limit, CARL reduces peak BESS power by 8.7--10.4\% and energy capacity by 47.5--62.6\% relative to conventional ramp-rate control while maintaining the grid-codes compliance.

0.20

Grid-Mode-Aware Model Predictive Control of Hybrid Energy Storage Systems for AI Data Center Power Smoothing

eess.SY ·2026-09-03 ·Xin Chen
similarity 0.63
Abstract

To facilitate the grid-friendly integration of highly variable AI data center loads, this paper proposes a grid-mode-aware model predictive control (G-MPC) framework for managing a hybrid energy storage system (HESS) to smooth grid-side power demand. The framework optimally coordinates a battery energy storage system (BESS) and a supercapacitor (SC) by solving a multi-step optimization problem in a receding-horizon manner. In particular, band-pass filter dynamics are directly embedded in the G-MPC formulation to extract and suppress grid-side power components associated with vulnerable grid oscillatory modes, thus mitigating load-induced grid oscillations. The resulting G-MPC optimization jointly minimizes violations of grid-side power-envelope, ramp-rate, and modal-power requirements and the degradation and power-ramping costs of the BESS and SC, while satisfying power limits, state-of-charge limits, and other operational constraints. To enable real-time implementation, a fix-and-re-optimize algorithm is developed to solve each G-MPC problem efficiently while preventing simultaneous charging and discharging. Extensive simulations demonstrate the effectiveness, flexibility, and computational efficiency of the proposed framework. The results also highlight the importance of explicitly suppressing power components associated with vulnerable grid modes, rather than merely reducing overall load variations, to effectively mitigate grid oscillations.

0.40

Optimal Coordination of Heat Pump Demand Flexibility and Battery Energy Storage Considering the Operation of Distribution Networks

eess.SY ·2026-10-06 ·Gustavo L. Aschidamini, Guilherme S. Castiglio, Mariana Resener
similarity 0.63
Abstract

Electrifying space heating with heat pumps (HP) and backup electric-resistance heaters (ERH) is incentivized to support decarbonization but increases voltage and thermal issues in distribution networks. Direct load control (DLC) of smart thermostats (ST) provide grid support, yet, to the best of our knowledge, existing methods do not co-optimize this flexibility with grid-scale battery energy storage systems (BESS) and voltage-regulation devices, and do not use ERH for preheating, limiting peak demand reduction and undervoltage mitigation. We propose a mixed-integer linear programming (MILP)-based model predictive control (MPC) framework that coordinates ST setpoints for preheating and setback, grid-scale BESS, on-load tap changers, switched capacitor banks, and step voltage regulators. The framework is evaluated on 23-node and 733-node distribution networks, including a real-data-based feeder, across multiple realized days. On the 23-node feeder with 50% HP penetration and 50% DLC participation, the proposed framework reduces the feeder peak by 23.1%, and by 27.1% with the co-optimized BESS. Rolling-horizon setpoint optimization contributes 6.5 percentage points beyond a day-ahead ST schedule (16.6%), and dispatching the ERH for preheating adds 2.7 percentage points beyond backup-only operation (20.4%). On the 733-node feeder, where thermal congestion is the binding constraint, the framework reduces overloaded branches by 94% and overloaded transformers by 47%. These results demonstrate the potential of coordinated demand flexibility and voltage regulation to accommodate heating electrification.

0.12

Real-Time Control of Sustainable Data Centers: A Two-Layer Model Predictive Control Framework with Workload Flexibility and Heat Recovery

eess.SY ·2026-08-17 ·Wenyu Liu, Enea Figini, Mario Paolone
similarity 0.62
Abstract · 22 pages, 14 figures

This paper proposes a two-layer model predictive control (MPC) framework for the real-time operation of data centers integrated with on-site photovoltaic generation, battery energy storage, waste heat recovery, and district heating. The upper layer employs scenario-based stochastic optimization to jointly optimize intraday market participation, workload scheduling, and energy management under uncertainty. The lower layer adopts an adaptive tube-based MPC strategy that compensates short-term disturbances while tracking the dispatch references given by the upper layer. The framework further integrates multi-horizon forecasting to support real-time decision making. Microservice-based simulation studies under representative clear-sky and overcast operating conditions demonstrate that the proposed framework accurately tracks dispatch plans despite fast photovoltaic and workload fluctuations. Compared with single-layer control strategies, the adaptive lower-layer controller substantially reduces real-time dispatch deviations and the associated imbalance costs. In addition, the proposed framework naturally adapts to seasonal operating conditions and responds to carbon-aware operating signals, offering a practical approach for economically efficient, sustainable, and grid-supportive operation of future data centers.

0.29

The Impact of PV Generation Forecast and Multi-Objective Control Policy on Optimal Operation of Grid Connected PV-BESS Microgrid

eess.SY ·2026-08-26 ·Berhane Darsene Dimd, Steve Voller, Ole-Morten Midtgård
similarity 0.62
Abstract

The variability of photovoltaic (PV) generation poses significant challenges to the reliable and efficient operation of grid-connected microgrids. Accurate PV output power forecasting and efficient energy scheduling strategies are essential not only for optimizing PV system operation but also for improving the overall performance and reliability of the system. This study proposes a long short-term memory (LSTM)-based PV power forecasting model integrated with a multi-objective scheduling framework for a grid-connected PV-battery energy storage system (BESS). The proposed approach enables detailed performance monitoring and assessment by quantifying how PV forecast accuracy influences key operational metrics, including PV self-consumption ratio, grid energy cost, grid injection, and battery utilization. Three forecasting scenarios (perfect forecast, persistence model, and LSTM-based forecast) are compared to evaluate their impact on system performance and operational reliability. Results show that the LSTM-based forecast reduces root mean squared error (RMSE) by 6% compared with the persistence model, increases the PV self-consumption ratio from 78.1% to 84.5%, and reduces grid injections by 82%. The analysis also highlights trade-offs, as higher battery throughput associated with improved performance may contribute to accelerated aging. These findings demonstrate the importance of accurate PV forecasting in improving system performance and ensuring reliable operation. Future work will focus on probabilistic forecasting to properly quantify uncertainties, incorporate load prediction, and develop smart control strategies that allow grid-support functionalities from the PV side.

0.32

Decision-Focused Learning for Optimal Battery Scheduling Under Load and Photovoltaic Power Uncertainty in Microgrids

eess.SY ·2026-10-10 ·Marios Saleptsis, Antoine Lesage-Landry, Marco Mussetta, Sonia Leva
similarity 0.62
Abstract · 20 pages, 13 figures, submitted to Sustainable Energy, Grids and Networks

The increasing penetration of renewable energy sources in microgrids demands accurate day-ahead forecasting to support optimal battery energy storage system (BESS) scheduling. Yet the conventional predict-then-optimize paradigm trains forecasters on statistical accuracy metrics that are agnostic to the asymmetric and time-varying cost impacts of forecast errors. This work proposes a decision-focused learning (DFL) framework that trains gated recurrent unit forecasters for both load demand and photovoltaic generation directly on the downstream operational cost of a two-stage energy management system, where day-ahead BESS commitments are fixed prior to real-time balancing. Gradients are backpropagated from the real-time operational cost through both optimization stages to the forecaster weights via implicit differentiation, enabling the forecasters to internalize the penalty structure of the scheduling problem. The framework is validated on the MG2Lab experimental microgrid testbed at Politecnico di Milano across two operational scenarios of increasing grid constraint and eight forecasting configurations comprising single-source and combined-forecaster settings. Results illustrate that the DFL-trained pipeline reduces operational cost by 3.78% under normal grid conditions and by 30.60% under grid-constrained conditions relative to the accuracy- optimized baseline, while nearly eliminating load shedding events. Notably, the DFL forecasters exhibit higher statistical errors than their accuracy-trained counterparts yet achieve consistently lower operational costs, confirming that forecast accuracy and decision quality do not share a monotonic relationship in constrained microgrid scheduling.

0.12

Adaptive Model Predictive Control for Damping IBR-Induced SSOs

eess.SY ·2026-11-11 ·Fiaz Hossain, Nilanjan Ray Chaudhuri, Constantino M. Lagoa
similarity 0.61
Abstract

We propose an adaptive model predictive control (MPC) approach to damp sub-synchronous oscillations (SSOs) induced by grid-following (GFL) inverter-based resources (IBRs). Unlike traditional model predictive controller designed considering the nominal plant that may not perform well in other conditions, we use plants that alter with changing operating point. To capture the plant dynamics, we use recursive least squares (RLS) based system identification with variable forgetting factor. This approach allows us to discount past data and avoid bias caused by large transient outliers while performing system identification. We present a proof of the convergence of the model parameters in the presence of finite outliers. We propose to update the model inside the MPC optimization problem periodically after a predetermined time interval instead of each sampling instant since the operating point changes slowly in a practical power system. The MPC design allows us to directly impose constraints on control inputs so that the IBR current limits are respected. Our approach also addresses the issue of unavailability of IBR models. We show the accuracy of the system identification and the superior performance of the proposed controller on the modified IEEE $4$-machine system and the modified IEEE $68$-bus system as compared with the traditional MPC.

0.29

Optimal Coordination of Multiple Ancillary Service Provisions in Active Distribution Networks

eess.SY ·2026-11-14 ·Xinbao Jia, Yi Guo, Ognjen Stanojev, Zhen Chen, Yuning Jiang +1 more
similarity 0.61
Abstract · 16 pages

We propose a multi-rate model predictive control (MPC) framework for coordinating primary frequency control (PFC), automatic generation control (AGC), and voltage control (VC) in active distribution networks. The framework allocates distributed energy resource (DER) flexibility among these three ancillary services while retaining their different update rates. To account for the intertemporal flexibility of electric vehicle aggregations and aggregations of buildings with thermostatically controlled loads (TCLs), we incorporate time-varying power-energy envelopes into our multi-rate MPC formulation. These constraints couple the combined PFC and AGC response to the demand-side flexibility available later in the prediction horizon. Furthermore, the input-multirate structure enables coordinated ancillary service provision by DERs with different response dynamics. The controller optimizes the three services together, allowing fast regulation to be coordinated with the developing slow response within the available DER flexibility. We demonstrate the coordinated provision of the three ancillary services through closed-loop simulations on a modified IEEE 33-bus system using a nonlinear differential-algebraic model.

0.25