CS Paper Radar

Integrating 3D Posture Neutralization with Statistical Shape Modeling for Head-Neck-Shoulder Ergonomic Design

Jinbo Luo, Hang Ren, Yadie Yang, Jie Zhang

cs.GR cs.CV ·submitted 2026-10-13 03:57 UTC · v1
unusual

Abstract

The design of ergonomic products and workspaces requires a deep understanding of human anatomy and posture. In particular, the head-neck-shoulder region is critical for many applications such as cervical orthoses, helmets, and other head-worn or neck-worn devices. This paper presents a framework that integrates posture neutralization with statistical shape modeling (SSM) for the head-neck-shoulder (HNS) region. We acquire a single three-dimensional (3D) scan of the head-neck-shoulder region from each of 200 Chinese adults in a natural posture for each subject. Every scan is then posture-neutralized before SSM. We fit a parametric head-neck model to each scan to separate cervical pose from anatomy, and reset the cervical pose to a common neutral configuration, so that the resulting model captures anatomical shape variation rather than posture-induced deformation. The resulting shape space yields a standardized template and population-wide modes of variation, providing baselines for parametric ergonomic design. We further discuss how the model supports population coverage analysis and the design of products that accommodate anatomical diversity while maintaining neutral cervical posture.

Comment
16 pages, 15 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

MedBOE: Optimization-Based Estimation of Complete Patient Body Models from Whole-Body Medical Imaging

cs.CV ·2026-10-20 ·Hoijoon Jung, Yuhao Wei, Mingxiao Tu, Younhyun Jung, Michael Fulham +1 more
similarity 0.59
Abstract · Hoijoon Jung and Yuhao Wei contributed equally to this work

True whole-body medical imaging captures a patient from head to toe and provides comprehensive anatomical and/or functional information. This coverage enables reconstruction of the external body surface, yielding patient body models. However, scanner geometry (e.g., bore diameter), patient characteristics, and positioning can leave body regions missing (e.g., lateral arms/torso, hands, forearms, elbows), producing incomplete patient body models. Such incompleteness limits downstream medical analyses, including derivation of body-habitus metrics (BHMs), such as body volume and surface area, for injected radiotracer activity regimens, cardiometabolic risk assessment, and computational anatomical modeling for medical imaging simulation and radiation dosimetry. We present the Medical Body model Optimization-based Estimator (MedBOE), an automated, training-free framework for estimating complete patient body models from whole-body images with missing body regions. Our innovation is to leverage the Skinned Multi-Person Linear (SMPL) template, a parametric body mesh representing a broad range of body shapes and poses, in medical imaging. MedBOE aligns the SMPL template to the incomplete patient body models via attribute-guided optimization and estimates missing body regions through geometrically and volumetrically constrained deformation. We evaluated MedBOE using two public datasets: AutoPET (91 whole-body PET-CT images) and Human Implicit Tissues (HIT; 40 whole-body segmentations from MRI images). MedBOE achieved the best overall volumetric and geometric performance among evaluated methods. BHMs derived from MedBOE were within 2% error, suggesting low percentage errors for downstream analyses. MedBOE offers an automated, training-free method for estimating complete patient body models from whole-body images with missing body regions.

0.23

TRACE: Artifact-Robust Statistical Shape Modeling from Imperfect Surface Scans - A Case Study in Craniosynostosis 3D Photography

cs.CV cs.AI ·2026-08-22 ·Sanjay Bhandari, Nawazish Khan, Alzbeta Novotna, Tiffany Jeong, Loretta Bowman +5 more
published similarity 0.57
Abstract · Accepted at ShapeMI workshop at MICCAI 2026

Craniosynostosis severity analysis increasingly relies on statistical shape models (SSMs) to quantify cranial morphology, but most existing workflows depend on computed tomography or heavily curated three-dimensional (3D) photographs. Raw clinical 3D photographs provide a radiation-free and repeatable alternative, yet often contain shoulders, hands, hair, clothing, scanner noise, and incomplete boundaries that corrupt correspondences. We introduce the Template-constrained Robust Artifact-aware Correspondence Estimation (TRACE) framework, an unsupervised method for constructing SSMs directly from artifact-contaminated clinical 3D head photographs. TRACE predicts sparse anatomically corresponding head-surface control points from the raw point cloud, refines them through a coarse-to-fine Surface-Aware Deformation cascade, and uses thin-plate spline warping to deform a clean template mesh into a subject-specific head reconstruction. This template-constrained formulation keeps dense correspondences on clinically relevant head anatomy while suppressing non-head artifacts. The correspondence module is decoupled from the point-cloud encoder, enabling the same deformation pipeline to be paired with different backbones, including PointNet, DGCNN, and Point Transformer V3. Across all backbones, TRACE substantially improves surface sampling, topology preservation, and shape-model quality over prior SSM methods, providing a scalable foundation for photograph-based craniosynostosis shape analysis and a framework that may extend to other artifact-contaminated surface scans when an appropriate clean template is available.

0.42

Validation of Smartphone-Based Photogrammetric 3D Body Scanning for Automated Anthropometric Measurements Compared with a Commercial Depth-Sensor-Based Body Scanner

cs.CV ·2026-08-13 ·Ruting Cheng, Boyuan Feng, Chuhui Qiu, Joaquin A. Calderon, Qing Pan +2 more
published similarity 0.56
Abstract · 16 pages, 5 figures, 4 tables

3D body scanning has become an important tool in healthcare applications because of its rapid and non-invasive nature. While smartphone-based photogrammetric reconstruction provide a low-cost and accessible alternative to commercial 3D body scanners, their performance for whole-body scanning remains insufficiently validated. Thus, we designed this study to comprehensively validate the photogrammetric 3D scanning application by evaluating automatically extracted whole-body measurements and longitudinal body-shape monitoring. We evaluated a representative application, PolyCam, against the commercial depth-sensor-based Fit3D ProScanner using 144 pregnant participants scanned longitudinally throughout pregnancy. We designed an automatic circumference extraction pipeline to get measurements at four anatomical landmarks from paired 3D scans. A linear mixed-effects model was used to evaluate scanner effects and longitudinal body-shape changes. Measurement consistency was assessed using repeated PolyCam scans and tape measurements on a rigid mannequin. PolyCam demonstrated strong agreement with Fit3D, with average biases below 16 mm, intraclass correlation coefficients above 0.8, and Pearson correlation coefficients above 0.9 across all landmarks. Both systems captured comparable longitudinal body-shape changes. Mannequin experiments showed mean biases below 3.5 mm and no significant differences from tape measurements. These findings support smartphone photogrammetry as a potential accessible alternative to commercial body scanners and applicable for longitudinal 3D body-shape assessment.

0.28

Prosthesis-Aware 3D Human Pose Estimation: A Dataset and Benchmark for RSP Users

cs.CV ·2026-09-16 ·Yilin Wen, Kechuan Dong, Fumiya Suginaka, Ken Endo, Yusuke Sugano
top venuebenchmarkdatasetcode/data similarity 0.55
Abstract · ECCV 2026. Project page: https://ut-vision.github.io/RSP3D/

Recovering 3D human body motion from video is important for applications such as rehabilitation assessment and sports performance evaluation. For prosthesis users, this requires capturing both natural body joints and the geometry of the prosthetic device, a challenge that existing methods are not designed to address. Model-based estimators rely on body models trained on non-amputee individuals and cannot represent prosthesis geometry, while model-free methods lack body kinematic priors and are unreliable under occlusion. This challenge is particularly prominent for users of running-specific prostheses (RSPs), where the RSP has a complex curved geometry and moves dynamically during exercise. To fill this gap, we collect RSP3D, the first 3D dataset of RSP users, covering essential daily-life and exercise actions from participants with varied amputation conditions, using a multi-camera marker-based motion capture setup. We formally define the task of prosthesis-aware 3D pose estimation, evaluate representative methods in a zero-shot setting, and confirm their individual limitations. We further propose a hybrid baseline combining model-based body joint estimation with model-free RSP shape recovery, establishing a starting point for future research.

0.50

Determination of the Human-Robot Interaction Workspace for Robot Assisted Head Stabilization Control

cs.RO physics.bio-phphysics.med-ph ·2026-10-19 ·Xinmin Liu, Alexander L. Van Slyke, Destinee Holloman, Ahmad Sakaamini, Rodney D. Wiersma
similarity 0.53
Abstract

Accurate head immobilization is critical for medical procedures such as neuroimaging and intracranial radiation therapy, where even minor motion can compromise precision. Traditional methods, such as rigid stereotactic frames and thermoplastic face masks, are invasive, uncomfortable for patients, and require a time-consuming setup. To overcome these limitations, a novel approach employs a 6-degree-of-freedom (6DoF) robotic head holder that is integrated with real-time optical motion tracking, enabling dynamic compensation for head movements without physical restraint. However, implementing this system requires a detailed biomechanical understanding of skull-cervical spine interactions to define safe and effective motion limits. In this study, we conduct a human volunteer investigation using a 6DoF Stewart platform robot to characterize biokinematic workspace of the head-neck system and establish foundational data for human-robot interaction in precision head stabilization.

0.21

Dressing in Motion: A Human Motion-Aware Diffusion Policy for Robot-Assisted Dressing

cs.RO ·2026-09-04 ·Haoxiang Sun, Fangyuan Wang, Songhao Huang, Justina Y. W. Liu, Jihong Zhu +2 more
similarity 0.53
Abstract · 9 pages, 11 figures

Robotic dressing assistance is a promising solution for supporting older adults with physical impairments in daily living. However, dressing under human motion remains challenging, as complex garment--human contact and occlusions make it difficult to generate actions aligned with arm movements. In this letter, we propose a visuomotor policy that learns dressing skills from static expert demonstrations and generalizes to dynamic user-motion scenarios. A diffusion policy tailored to garment--human interaction geometry learns from partially observed point clouds with varied arm postures. We then introduce an object-centric representation based on PDE diffusion to capture the axial distribution of the arm. By sampling motion-relevant regions and registering them across consecutive observations, the proposed method approximates arm motion and reactively adapts the executed trajectory. We evaluate our method in simulation and a real-world human study involving nine participants, three garment types, and six arm-motion patterns. Results show that our method outperforms baselines in dressing progress, freedom of movement, and user comfort. The project website is https://anonymous.4open.science/w/dressing-in-motion.

0.46

PressureMesh: 3D Human Mesh Estimation from Multi-Device Pressure Images

cs.CV ·2026-08-10 ·Changhai Ma, Ziyu Wu, Yunkang Zhang, Fangting Xie, Mengting Niu +6 more
similarity 0.53
Abstract

Human pose monitoring is crucial in fields such as rehabilitation assessment and human-computer interaction. Due to its privacy-preserving nature, pressure-based human pose monitoring has become a primary approach for unobtrusive sensing. However, existing methods are generally limited to a single device, which restricts the effective monitoring range. To address this limitation, we propose MDP-Net, an end-to-end network capable of directly estimating human meshes from temporal pressure data across multiple devices. We introduce a multimodal fusion mechanism inspired by the Mixture of Experts (MoE) framework to achieve effective complementarity and enhancement of cross-device pressure information. To support the training and evaluation of MDP-Net, we constructed MDP, a high-quality multi-device temporal pressure dataset that includes various pose labels such as 2D/3D joints and human meshes. Experimental results demonstrate that MDP-Net achieves a joint position error of 12.6 cm on the MDP dataset. These results prove that fusing multi-device pressure information is an effective and promising new solution for daily human pose monitoring.

0.04

Mesh-Agnostic Refinement Models for Latent Space Encoding of 3D Human Body Shapes

cs.CV ·2026-11-02 ·Chaima Zouaoui, Jonathan Cerqueira, Sylvain Arguillere, Martin Bauer, Nicolas Charon +2 more
similarity 0.53
Abstract

Parametric human body models such as the Skinned Multi-Person Linear (SMPL) model provide compact representations of human shape and pose, but their reconstructions remain affected by both errors in estimated latent parameters and limitations in the decoder's expressive capacity. We propose a framework for refining these reconstructions by exploiting the geometric discrepancy between an initial decoded surface and a target mesh, without requiring vertex correspondences between them. The framework comprises three complementary approaches. Latent-VaRefine uses varifold distance gradients to correct the estimated latent code while preserving the original parametric representation. Vertex-VaRefine processes multiscale varifold-gradient features with a DiffusionNet backbone to predict vertex displacements in a canonical pose, yielding an approximately pose-equivariant refinement pipeline. ElaOpt directly optimizes surface deformations under elastic regularization and normal direction constraints. On AMASS, Vertex-VaRefine reduces the mean vertex-to-vertex error of OmniFit reconstructions from 1.181 to 0.342 cm, a 71.0 percent reduction, while combining Latent-VaRefine with ElaOpt reduces the asymmetric Chamfer distance of ArtEq reconstructions from 1.681 to 0.717 cm, a 57.3 percent reduction. Evaluations with SMPL-H and SMPL-X demonstrate the framework's adaptability to different body models, while additional experiments on remeshed targets and raw scans assess its robustness to changes in discretization and geometry beyond the parametric model. These results highlight the complementary strengths of latent space correction, learned vertex refinement, and elastic optimization, offering different trade-offs between preserving the model parameterization and improving geometric fidelity.

0.24