Accurate head immobilization is critical for medical procedures such as neuroimaging and intracranial radiation therapy, where even minor motion can compromise precision. Traditional methods, such as rigid stereotactic frames and thermoplastic face masks, are invasive, uncomfortable for patients, and require a time-consuming setup. To overcome these limitations, a novel approach employs a 6-degree-of-freedom (6DoF) robotic head holder that is integrated with real-time optical motion tracking, enabling dynamic compensation for head movements without physical restraint. However, implementing this system requires a detailed biomechanical understanding of skull-cervical spine interactions to define safe and effective motion limits. In this study, we conduct a human volunteer investigation using a 6DoF Stewart platform robot to characterize biokinematic workspace of the head-neck system and establish foundational data for human-robot interaction in precision head stabilization.

Closest papers

Nearest neighbours by meaning across the whole index.

A Biomimetic Gaze Control to Restore Head-Neck Movements

cs.RO ·2026-10-02 ·Colin Rubow, Haohan Zhang
top venue similarity 0.61
Abstract

Powered neck exoskeletons are developed to restore head-neck motions for those with neck muscle weakness. Current methods using hand-held input devices to control these robotic systems are unintuitive or non-viable for these populations. Alternatively, the eyes coordinate with the head to accomplish many daily tasks. Therefore, movements of the eyes can be a useful signal to control the neck exoskeletons without needing to use the hands. However, previous control models lack biobehavioral basis as well as means to personalize the control behavior, causing unnatural head-neck movements. This paper presents a novel eye-tracking controller design leveraging the vestibulo-ocular reflex to emulate natural eyehead coordination. Personalization tools were also designed, consisting of sliders to allow users to adjust the parameters of this controller. Here, we present the technical design and validation of this system in human users. Compared to the previous eye-tracking model, the new controller provides natural head motions personalized to the user through more natural velocity profiles and a 24 percent average increase of accurate motion intent detection. This system provides a powerful platform for studying eye-tracking controllers in the context of personalization and preference, and ultimately restoring the lost head-neck mobility in patient populations.

0.51

Bi-manual Stabilization of the Cervical Spine for Safe Physical Human-Robot Interaction in Rolling Maneuvers

cs.RO ·2026-10-03 ·Elizabeth Peiros, Moira Bohley, Lucas Yager, Derek Chen, Rebecca Fellbaum +4 more
similarity 0.57
Abstract · 8 pages, 8 figures

The neck, specifically the cervical spine, is a highly fragile and mobile part of the body with a high risk of catastrophic injury. Whether someone is injured on a battlefield, in a natural disaster, or in an athletic event, great care is always taken with the cervical spine when transporting, rolling, or moving the patient. In this work, we present an algorithm and adaptations for bi-manual robots to stabilize the cervical spine during rolling maneuvers. We investigate techniques to maximize grip strength within safety bounds and present a control approach for proper neck rotation. We found that with our approach, a bi-manual robot is capable of achieving human-level performance in maintaining target rotational alignments. The axial alignment for the robot with prediction was within .21 degrees of human novices.

0.29

Integrating 3D Posture Neutralization with Statistical Shape Modeling for Head-Neck-Shoulder Ergonomic Design

cs.GR cs.CV ·2026-10-13 ·Jinbo Luo, Hang Ren, Yadie Yang, Jie Zhang
unusual similarity 0.53
Abstract · 16 pages, 15 figures, 1 table

The design of ergonomic products and workspaces requires a deep understanding of human anatomy and posture. In particular, the head-neck-shoulder region is critical for many applications such as cervical orthoses, helmets, and other head-worn or neck-worn devices. This paper presents a framework that integrates posture neutralization with statistical shape modeling (SSM) for the head-neck-shoulder (HNS) region. We acquire a single three-dimensional (3D) scan of the head-neck-shoulder region from each of 200 Chinese adults in a natural posture for each subject. Every scan is then posture-neutralized before SSM. We fit a parametric head-neck model to each scan to separate cervical pose from anatomy, and reset the cervical pose to a common neutral configuration, so that the resulting model captures anatomical shape variation rather than posture-induced deformation. The resulting shape space yields a standardized template and population-wide modes of variation, providing baselines for parametric ergonomic design. We further discuss how the model supports population coverage analysis and the design of products that accommodate anatomical diversity while maintaining neutral cervical posture.

0.25

A Head Camera Is (Almost) All You Need: An Electronics-Free UMI Glove Labelled and Observed by One Moving Camera

cs.RO cs.AI ·2026-10-20 ·Yosub Shin, Yuan Liu, Igor Molybog
similarity 0.53
Abstract

Handheld demonstration devices decouple data collection from the robot, but conventional designs burden the hand with a wrist camera, cables and a pose tracker (SLAM, an IMU, a VR controller, or a fixed external camera that the collector's body occludes), and burden the pipeline with as many data streams to timestamp, synchronise and cross-calibrate. We show that a single egocentric camera (USD 122) worn on the collector's head replaces the wrist camera, the pose tracker and their separate streams with one. It reads printed fiducials on an electronics-free glove (USD 22) against paper tiles taped around the workspace, giving the 6-DoF gripper pose and the jaw width from the same frames the policy will see; at deployment the same camera rides a low-cost (USD 120) arm beside the robot that mimics the collector's head from the robot's joint state. Against the robot's encoders the labels are accurate to 6.5 mm and 1.6 degrees median with 93-100% frame coverage, and a policy trained on them instead of encoders pays 3% in validation loss. Adding 194 glove demonstrations to 48 teleoperated episodes lifts rollout success from 10/25 to 17/25, level with 172 teleoperated episodes alone (18/25), and the full co-trained head-camera policy succeeds in 20/25 against 15/25 for the wrist-camera recipe, whose policies drop the object when the goal leaves their view, and 12/25 for a fixed camera.

0.14

Novel Ex-vivo Calf Brain Model with Integrated Sub-Skull Force Sensors to Access Simulated Neurosurgical Procedures

cs.RO eess.SY ·2026-09-13 ·Hamad Binhammad, Matheus Ballestero, Mohammed Babgi, Seana Shaka, Nima Hemati +7 more
similarity 0.52
Abstract

Surgical tissue manipulation demands precision; however, tool-tissue manipulation force magnitudes under realistic conditions are rarely quantified. To address this gap, we proposed and validated a portable ex-vivo force-sensing platform that measures tool-tissue interaction forces across the skull-brain interface during simulated neurosurgery. The system involves fresh calf brain tissue, used as a biological surrogate for brain parenchyma, placed in a 3D-printed human skull model equipped with a 6 degree-of-freedom force/torque sensor and a real-time data acquisition system. Five validation protocols assessed the accuracy and dynamic fidelity of the platform against ground-truth measurement, static accuracy and linearity using calibrated weights (0.5-50 g), minimum detectable force, spatial consistency across different anatomical regions, effect of surgical draping, and long-duration stability. Across protocols, measured forces showed excellent agreement with reference loads (correlation R = 0.9997), with RMSE < 0.005 N and mean relative error under 2%. The platform reliably detected low-magnitude forces down to 1 g (9.8 mN), while surgical drapes introduced no meaningful signal distortion and prolonged recordings exhibited minimal drift. Overall, the proposed framework provides objective, high-fidelity force quantification for skill training and performance assessment using fresh calf brain tissue and may serve as a foundation for force-based evaluation across other surgical procedures. Future work will integrate clinically used surgical instruments to increase procedural realism and will progress toward clinical trials to evaluate usability, educational impact, and translational relevance in practice-adjacent settings.

0.25

LARK: A Low-Cost, Accurate, Occlusion-Resilient, Kalman Filter-Assisted Tracking System for Image-Guided Surgery

cs.CV eess.IV ·2026-10-06 ·George Sideris, Justin Cree, Andrew Stirling, Mamadou Ly, Étienne Léger +1 more
similarity 0.52
Abstract · 24 pages, 15 figures, including appendices. Supplementary document included as an ancillary file. Supplementary video: https://youtu.be/ApZ8…

Image-guided surgery (IGS) depends on accurate tracking of surgical instruments to provide real-time navigation relative to anatomical structures. Commercial stereo infrared trackers are accurate but prone to occlusion and cost-prohibitive for many settings. This work presents LARK, a multi-camera optical tracking system using commodity RGB hardware and multi-view redundancy and fusion. We develop and evaluate two complete tracking methods: multi-view monocular pose fusion and multi-view triangulation. Both methods are assessed under varying occlusion levels using a precision-machined grid and an anatomical head phantom, and compared against a gold-standard stereo infrared system. With five cameras and adaptive Kalman filtering, LARK achieves median target registration errors of 0.64 mm for point localization with triangulation and 0.73 mm for trajectory tracking with pose fusion on the machined grid. Camera-subset experiments show graceful degradation in adaptive pose-fusion accuracy as fewer views remain available. With tracking hardware costing under $1,000 USD, LARK provides a low-cost platform for image-guided surgery research. Hardware designs and software are publicly available at https://nist.mni.mcgill.ca/software/ , and datasets at https://nist.mni.mcgill.ca/data/ .

0.25

Active Constraints for Simultaneous Guidance and Safety in Handheld Micromanipulation

cs.RO ·2026-10-27 ·Roger Ho, Robert A. MacLachlan, Cameron N. Riviere
similarity 0.51
Abstract · 8 pages, 3 figures, submitted to ICRA 2027

In micromanipulation, erroneous hand motion limits unaided manipulation accuracy, which can affect task performance and safety in critical applications like microsurgery. Handheld robots (micromanipulators) enable motion accuracy beyond human limits by providing robotic assistance in a low-cost, compact, intuitive form factor. Particularly, active constraints are an effective form of robotic assistance, which aids the operator by restricting the robot's permissible motion based on task-specific requirements or objectives, thereby providing task guidance and enforcing safety. However, existing formulations of active constraints for handheld systems are limited, most notably because of the inability to provide guidance and enforce safety simultaneously. Implementing active constraints with optimization-based methods can address these limitations, but existing implementations are designed for free-standing robots, and neglect that handheld robots actuate relative to the operator's hand with a limited workspace. In this work, we propose an optimization-based active constraint framework for handheld micromanipulation that enables simultaneous guidance and safety enforcement. The formulation was implemented in a handheld robot and demonstrated on a medically relevant artificial task. Results show that the proposed formulation reduced safety violation rate by more than two orders of magnitude relative to baselines, while recovering the threefold accuracy loss from enforcing safety alone.

0.38

Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

cs.RO ·2026-09-22 ·Chang Liu, Chenhao Yu, Honghao Zhao, Hao Ding, Haochen Wei +3 more
published similarity 0.50
Abstract · 8 pages, 8 figures. Accepted to IROS 2026

Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital twin-driven virtual reality (VR) teleoperation platform, where the digital twin is created from markerless perception of the surgical environment and streamed for display on the HMD. This overcomes the limitations of video pass-through by providing multi-view rendering and natural motion-parallax cues, enabling decoupling of the user's hand posture from strict instrument alignment. The system utilizes VR hand controllers to increase the teleoperation workspace and to improve the robustness and stability of instrument control compared to the hand tracking approach adopted by most prior systems. A 15-participant user study on the da Vinci Research Kit (dVRK) shows that our VR platform significantly outperforms a state-of-the-art HoloLens 2 mixed reality baseline, reducing path length by 86% and jerk by 95%, while achieving depth perception confidence comparable to or exceeding the traditional console across all conditions.