CS Paper Radar

XoNav: An Exoskeleton as a Personalized Haptic Interface for Assisted Navigation

Debadrata Sarkar, Soumen Sen, Aman Arora

cs.RO ·submitted 2026-10-19 20:44 UTC · v1

Abstract

Walking without vision requires timely, unambiguous guidance, yet many wearable aids encode directions as audio or vibrotactile signals that users must translate into movement. We present XoNav, a four-actuator hip exoskeleton that renders guidance cues directly at the hip joints. It renders an Advance cue and two-level Braking cues through sagittal-plane actuators and two-level Steering cues through frontal-plane actuators. A bilateral LSTM-based gait-state classifier uses two thigh-mounted IMUs to identify gait states, enabling haptic cues to be delivered in coordination with the wearer's gait while suppressing them during standing. The classifier generalized to unseen users with recalls of 95.2-97.9%, with mean detection delays of 38.6 and 63.1 ms for stance-to-swing and swing-to-stance transitions, respectively. Constrained human-in-the-loop Bayesian optimization personalized Braking for minimum resistance and Steering for maximum comfort while ensuring detectability and safety. All participants reliably distinguished between grades of their personalized cues and the firmest Braking cue remained below 53% of the safety limit. In blindfolded Wizard-of-Oz navigation trials along three paths, the participants kept 98.8% of the walked distance within a 0.75 m wide passage, with a 4.9% increase in mean progression speed per trial. A body-worn camera, RTAB-Map and Nav2 further enabled a feasibility study of autonomous navigation and detours around previously unmapped obstacles.

Comment
A supplementary video illustrating the XoNav hardware, haptic cues, Wizard-of-Oz trials and autonomous navigation is available at https://doi.org/10.6084/m9.figshare.34701648

Closest papers

Nearest neighbours by meaning across the whole index.

Blind Dexterity: Whole-Body Humanoid Manipulation via Pure Proprioception

cs.RO ·2026-08-30 ·Aditya Bhatt, Oleg Kaidanov, Puze Liu, Jan Peters
positioncode/data similarity 0.64
Abstract · 9 pages, 6 figures. Project page: https://aditya.bhatts.org/BlindDexterity/

We present blind, whole-body manipulation skills on a Unitree G1 humanoid using only onboard proprioception, without cameras, markers, force-torque, or tactile sensors. Despite this minimal sensing, the trained policies exhibit surprising capability across qualitatively different tasks: push-resilient bipedal walking without IMU feedback, active soccer ball trapping with a foot, seeking and lifting a suitcase by its handle, and mounting a randomly positioned skateboard. We argue that these capabilities arise from a key underappreciated signal: the way the joint encoder readouts evolve under purposeful compliant contact, effectively forming a whole-body tactile channel. By generating contact-rich motions, the trained policies actively probe the environment; as a result, task-relevant object state (e.g., pose) becomes increasingly decodable from short proprioceptive histories. We expose this information using compact task-specific state estimators trained alongside, but fully separately from, the policies; their prediction errors decrease rapidly after informative contact. Our results indicate that joint encoder-based proprioception, combined with compliant actuation (now widely available on commercial robots and low-cost motors) is already a strong, practical substrate for whole-body dexterous manipulation and interactive perception, and therefore a natural foundation on which richer sensing can be layered.

0.43

Autonomous Telerehabilitation via Skeletal Motion Prediction and Joint-Level Performance Assessment

cs.CV cs.LG ·2026-08-12 ·Lara Pereira, João Ruivo Paulo, Pedro Santos, Paulo Peixoto
published similarity 0.62
Abstract · Accepted at IEEE RO-MAN2026

Autonomous rehabilitation systems must not only recognize human motion but also provide structured feedback to support users without continuous therapist supervision. This paper presents a telerehabilitation pipeline that integrates skeleton-based exercise quality assessment and short-term motion prediction into a two-module system operating on marker-free RGB video. A self-attentive Bidirectional LSTM performs exercise quality classification using MMD-NCA metric learning, while a graph-based motion prediction module computes per-joint position errors between predicted and observed poses, generating spatially localized deviation signals. Each module is evaluated independently on established benchmarks: the classifier achieves 96.45% mean-class accuracy on squat sequences from the PROZIS dataset, and the adopted STARS predictor achieves a mean MPJPE of 75.8 mm at 560 ms on Human3.6M, outperforming graph and recurrent baselines across all prediction horizons. The framework is designed for eventual deployment in assistive robotics and home-based rehabilitation contexts; end-to-end integration and clinical validation are important directions for future work. By combining motion recognition and prediction in a single system, this work contributes a step toward autonomous, feedback-driven telerehabilitation, for more accessible and scalable rehabilitation solutions.

0.23

Learning a Speed-adaptive Hip Exoskeleton Control Policy Via Sim-to-real Reinforcement Learning

cs.RO ·2026-09-23 ·Bin Li, Zhimin Hou, Jiacheng Hou, Zenian Liang, Tong Wu +2 more
similarity 0.62
Abstract

Providing personalized exoskeleton assistance across varying walking speeds remains challenging. Existing online optimization methods are sample-inefficient, requiring extensive human-in-the-loop (HIL) evaluations to optimize the entire assistive torque profile. Sim-to-real reinforcement learning (RL) offers a promising alternative but cannot directly account for individual user preferences. We propose a framework integrating sim-to-real RL with online preference learning for personalized exoskeleton assistance. Specifically, assistance timing is learned in simulation by training RL policies with human musculoskeletal models across varying walking speeds. The learned policies are then distilled and deployed on a physical hip exoskeleton using onboard sensory observations. Gaussian-process-based preference learning further personalizes the assistance magnitude through pairwise user comparisons. By decoupling assistance timing learning in simulation from magnitude optimization in real-world experiments, our framework substantially reduces the online optimization space. Human-subject experiments demonstrate efficient identification of personalized assistive torque profiles across varying walking speeds with fewer real-world evaluations.

0.14

Tread: A Visuo-Inertial Framework for Terrain and Locomotion Context-Aware Gait-Phase and Speed Estimation in Wearable Robotics

cs.RO ·2026-10-13 ·Debadrata Sarkar, Akash Bachhar, Aman Arora
similarity 0.61
Abstract · Supplementary video: A video demonstrating real-time operation of the complete visuo-inertial inference pipeline is available at https://doi…

A wearable assistive robot must continuously estimate terrain, locomotion mode, gait phase, and walking speed. These quantities are commonly addressed by separate, terrain-specific models, with datasets rarely collected under a common protocol. This paper presents a visuo-inertial framework that connects these estimates through a causal pipeline using a chest-mounted camera and four lower-limb inertial measurement units (IMUs). Anticipatory Terrain Perception (ATP) classifies incoming terrain with 96.3% accuracy and anticipates terrain transitions by 1.46 s on average. Terrain-Aware Locomotion Mode Identification (TALMI) achieves 93.7% and 98.8% accuracy for its level-ground and stairs experts respectively, with mean transition latencies being below 200 ms. The relevant TALMI posterior is retained as a Probabilistic Locomotion Context (PLC) vector and provided to a shared Gait Kinematic Encoder (GKE), which supports 50-Hz bilateral gait-phase estimation and 2-Hz walking-speed estimation. Leave-one-subject-out evaluation yields gait-phase RMSEs of 1.75%, 2.97%, and 4.55% for level walking, stair ascent, and stair descent respectively while estimating speed over 3.5-5.5 km/h with a RMSE of 0.218 km/h. All inertial sensing based models use sensor-fused Euler angles as input rather than raw accelerometer and gyroscope signals, reducing dependence on sensor mounting variation.

0.26

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.61
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.48

Designing wearable haptic cueing for neurological gait rehabilitation: user requirements across residential care and community settings

cs.HC ·2026-10-30 ·Riasat Islam, Annemarie Zijlema, Theodoros Georgiou, Simon Holland, Blaine Price +3 more
similarity 0.61
Abstract · 38 pages, 2 figures, 4 tables. Preprint; manuscript currently under review in following journal - Disability and Rehabilitation: Assistive T…

Wearable haptic cueing offers rhythmic prompts for neurological gait rehabilitation while leaving hearing available for communication and environmental awareness. We investigated the user, design, and implementation requirements needed to make these systems usable in practice. We analysed six linked studies involving 17 people with neurological conditions affecting gait and three physiotherapists across formative sessions, residential care, and community self-management. Wearable devices served as technology probes. Observations, interviews, diaries, physiotherapist records, gait analysis, and activity logs informed thematic analysis and cross-study comparison. Seven recurring requirement areas concerned haptic perceptibility and placement, wearability and fastening, interaction burden, rhythm personalisation, real-world walking contexts, supported use, and perceived value beyond gait outcomes. Requirements interacted: perceptible cue locations could be difficult to access for fastening or control, while fixed rhythms did not always accommodate terrain, fatigue, interruptions, or changing pace. Carers and clinicians supported configuration, operation, safety, and interpretation. Participants described confidence, routine formation, and willingness to walk; these accounts were interpreted as perceived value rather than evidence of therapeutic efficacy. Low sensation, cognitive burden, and mobility limitations could make wearable cueing impractical. Future systems should offer adjustable haptic output, flexible placement, accessible fastening, simple controls, personalised rhythms, and robustness during everyday walking. Design should accommodate support from carers and clinicians and consider trade-offs between requirements. These findings inform wearable rehabilitation design rather than establish clinical efficacy.

0.28

MotionDecipher: LLM-Assisted Clinical Interpretation of Human Motion Signals for Efficient Gait Analysis

cs.HC cs.AI ·2026-11-05 ·Mingrui Ma, Tian Tan, Jinsi Guo, Jessica Rose, Yiwen Dong
published similarity 0.61
Abstract · 33 pages, 19 figures, 2 tables. Accepted to Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies (IMWUT), Vol…

Clinical gait and motion analysis is widely used to guide targeted interventions for patients with neurological disorders, the outcome of which is typically a report with descriptions of joint movements and forces. Current practices rely on experts' manual effort, which is labor-intensive and time-consuming. Recent advancements in Large Language Models (LLMs) provide opportunities to address this problem, but translating human motion into clinical gait descriptions remains challenging because the quality of the context directly affects LLMs' reasoning capability over continuous motion signals. To tackle this, we introduce MotionDecipher, a novel framework bridging the semantic gap between motion data and clinical interpretations. Specifically, we made 3 key advancements: 1) a Human Motion Tokenizer that converts motion signals into domain-specific tokens for time- and frequency-informed gait interpretation; 2) a Meta Feature Selector that transforms tokens into Structured Representations; and 3) a Hybrid Context Constructor to determine the optimal demonstration-based prompt for In-Context Learning. We evaluated MotionDecipher on data collected at an accredited gait lab from 122 patients and 46 controls. Results show that MotionDecipher achieves 0.91 BERTScore (13% over GPT-5), while expert evaluation ranks MotionDecipher highest in Correctness, Completeness, and Conciseness compared to baselines, highlighting its promise for efficient gait analysis.

0.31

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.61
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13