CS Paper Radar

Explicit Convex Inner Approximation of TSO-DSO Flexibility Regions via Exact Second-order Cone Relaxation in Radial Networks

Wenyu Liu, Mario Paolone

eess.SY ·submitted 2026-10-20 09:16 UTC · v1
benchmark

Abstract

Accurate representations of the flexibility in distribution grids via tractable algorithms are essential for TSO-DSO coordination. However, flexibility region (FR) estimation based on nonlinear optimal power flow (OPF) generally lacks feasibility guarantees, while conventional convex relaxations may suffer from inexactness. This paper proposes a framework for constructing explicit inner approximations of active-reactive power FRs in radial networks based on the augmented relaxed OPF (AR-OPF). First, less-conservative sufficient conditions for the AR-OPF exactness are derived and extended to generalized objectives. Furthermore, an interior-feasibility analysis is established, guaranteeing that the entire region enclosed by the traced boundary is AC feasible under the proposed sufficient conditions. Building on these theoretical results, two adaptive algorithms are developed to construct explicit inner approximations and numerically convex representations of FRs. Numerical evaluations on different benchmark networks demonstrate consistently small relaxation residuals and high flexibility area retention in most cases, showing that the proposed methods provide a grounded approach to construct operationally admissible FRs for TSO-DSO coordination.

Comment
10 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Quantifying the Cost of Restoring AC Feasibility for Approximate Optimal Power Flow Solutions

eess.SY math.OC ·2026-11-11 ·Sanjay Johnson, Sungho Shin
theory similarity 0.62
Abstract · 5 pages, 4 figures, submitted to 2027 IEEE Power & Energy Society General Meeting

Power system operations rely on approximate solutions of the AC optimal power flow problem, most notably the DC optimal power flow used in security-constrained unit commitment and economic dispatch, while convex relaxations, machine learning surrogates, and other approximations are studied extensively in the academic literature. Because these approximations neglect or relax parts of the AC power flow equations, their solutions must be adjusted before dispatch; for example, the DC optimal power flow, which neglects transmission losses, reactive power, and voltage magnitude variations, is known to produce solutions that are always infeasible. The cost of this adjustment is not adequately understood. This paper proposes a method that quantifies, for any approximate solution, the minimum cost of the adjustments that restore AC feasibility, which is a lower bound on the cost of the heuristic adjustments used in practice. We apply it to the DC optimal power flow, the second-order cone and quadratic convex relaxations, and the AC optimal power flow solved to a loose relative tolerance of $10^{-4}$ instead of $10^{-8}$. Relative to the AC optimal power flow solution obtained from a local nonlinear optimization solver, and even with the minimum adjustment, the DC optimal power flow requires adjusting, on average, generators that account for 15.6% of total generation capacity and incurs a 1.10% cost increase; the convex relaxations require more adjustment (17.2% and 16.9%) but smaller cost increases (0.68% and 0.78%); and the loose-tolerance AC optimal power flow requires 6.1% and incurs 0.42%. These results indicate significant value in operating markets directly on the AC optimal power flow, which avoids the distortion of the dispatch and prices caused by heuristic feasibility restoration.

0.35

Controller- and Communication-Aware Flexibility Margins for Electric Distribution Networks

eess.SY ·2026-10-14 ·Saif R. Kazi, Kaarthik Sundar
similarity 0.61
Abstract · 11 pages

This paper develops a framework for quantifying operational flexibility in radial electric distribution systems under coupled active- and reactive-load uncertainty. Flexibility is defined as the largest scaling of a prescribed uncertainty set that can be accommodated while satisfying network and actuator limits under a given control architecture. We consider a one-sided Euclidean set for robust demand-growth capability, with a direct extension to bidirectional variations. Under LinDistFlow, controllable distributed resources and feeder-head exchange with the upstream grid jointly balance active-power disturbances, while local Volt/VAR feedback regulates reactive power. The resulting affine closed-loop disturbance response admits exact second-order-cone robust counterparts. For fixed Volt/VAR gains, a convex reformulation jointly optimizes the flexibility margin and active-power participation factors, including feeder-head participation. A sparse load-to-generator feedforward map further captures communication constraints. Numerical studies on the Iowa-240 feeder demonstrate how the amount of control authority and communication structure shape the achievable flexibility margin.

0.24

Harmonic-Constrained Hosting Capacity of Active Distribution Networks Using ESS Compensation and Certified Adaptive Decision-Tree Envelopes

eess.SY ·2026-11-16 ·Pengyu Ren, Wei Sun, Fei Teng, Gareth Harrison
similarity 0.61
Abstract

Active distribution networks increasingly rely on coordinated inverter-based resources to accommodate renewable generation, while harmonic limits constrain the capacity that can be connected. This paper proposes a harmonic optimal power flow (HOPF) method with active energy-storage-system (ESS) support. ESS charging, discharging and harmonic-current compensation are jointly scheduled under state-of-charge dynamics and a shared converter-current rating. An adaptive decision tree learns voltage-current partitions from OPF operating points. Within each leaf, an affine plane is fitted on an analytic grid and certified as a lower envelope. A disaggregated mixed-integer formulation embeds these envelopes in a second-order-cone-relaxed network model. Annual hourly data are assessed through daily capacity optimization, followed by componentwise capacity aggregation and chronological full-year feasibility validation. In the case study, the OPF reference of 65.572 MW exceeds the adopted harmonic bounds, whereas HOPF without harmonic support yields an annually validated capacity of 56.892 MW. With each generator capacity bounded by its OPF reference, the proposed method recovers the complete reference allocation. Coordinated energy dispatch and harmonic compensation thus recover generation capacity within the installed ESS converter ratings.

0.25

Modeling of Network Constraints in Large-scale Capacity Expansion Optimization of Power Grids

eess.SY math.OC ·2026-08-28 ·Yu Weng, Lara Booth, Priya L. Donti, Ruaridh Macdonald
publishedtheoryhot direction similarity 0.59
Abstract

Capacity expansion modeling plays a critical role in optimizing the deployment of new generation, storage, and transmission, typically at national and regional levels. To support long-term planning, these models consider a large set of energy technologies and policies, along with decades of weather and demand data. Realistic capacity expansion models thus become high-dimensional optimization problems, with hundreds of millions of variables and constraints, which are challenging to solve. A common strategy to address this complexity is to omit non-linear, non-convex AC optimal power flow (ACOPF) constraints and instead use linearized power balance equations or transport formulations. While these simplifications improve tractability, they limit our understanding of how power flow and the physical properties of power networks impact investment decisions across generation, storage, and transmission infrastructure. This paper addresses this gap by extending the GenX capacity expansion model to incorporate fixed point theorem-based network constraints. These embed ACOPF-based considerations while maintaining the tractability of the planning model, nearly preserving the dimensionality of the transport formulation and incurring only modest runtime increases. This approach is much cheaper than embedding ACOPF directly, making it appropriate for large-scale capacity planning problems. We compare our approach to the original transport-based GenX model as well as a non-linear, non-convex version that incorporates the full ACOPF constraints, for a case study of the ISO New England grid.

0.47

Computationally Transparent Power Flexibility Aggregation via Directional Support Evaluation

eess.SY ·2026-10-21 ·Mingyu Zhai, Liang Du, Yue Chen
similarity 0.59
Abstract · Preprint. Submitted for journal review

The growing penetration of distributed energy resources (DERs) creates new opportunities for improving resource adequacy, operational flexibility, and power-system reliability. However, efficiently characterizing the aggregate flexibility of heterogeneous DER portfolios remains challenging because of high dimensionality, diverse operating dynamics, and spatio-temporal coupling constraints. This paper proposes a computationally transparent framework that formulates aggregate flexibility characterization as a sequence of linear programming (LP)-based directional support evaluations. The framework accommodates heterogeneous DER technologies and configurable device-, feeder-, and portfolio-level constraints. The convex hull of the resulting boundary trajectories provides a feasible inner approximation of the coupled aggregate power flexibility region. Theoretical analysis establishes feasibility and non-overestimation guarantees and characterizes the computational dependence on portfolio size, scheduling horizon, and direction budget. In the small-scale case, the proposed method produces tighter projected regions than box, zonotope, and Chebyshev inner-ball benchmarks and matches a dense directional reference within numerical tolerance using 16--64 construction directions. Large-scale simulations with up to 2000 DERs demonstrate approximately linear empirical runtime scaling with the portfolio size and direction budget over the tested ranges. The results establish a scalable and theoretically grounded approach for aggregate DER flexibility characterization.

0.27

A Deficiency-Based Approach for Unbalanced Three-Phase Distribution System Expansion Planning

eess.SY ·2026-10-12 ·Eli Brock, Miguel Heleno, Javad Lavaei, Somayeh Sojoudi
benchmark similarity 0.58
Abstract · 12 pages, 1 figure, 3 tables. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice…

Distribution planners typically characterize grid needs through power flow studies and fit upgrades to those needs by hand. More principled one-shot optimization methods either do not scale or misrepresent unbalanced three-phase networks. This paper proposes an iterative planning process that alternates between two problem classes with mature off-the-shelf solvers. An optimal power flow (OPF) problem quantifies the deficiency of a candidate portfolio by optimizing the dispatch of controllable devices and measuring thermal and voltage violations on a common scale, with an optimal value of zero exactly at adequate portfolios. The OPF multipliers give a first-order approximation of the relief each investment candidate would provide. We bound the error of this approximation and show that structural properties of the deficiency guard it against overestimation. Building on this property, a heuristic cutting-plane search uses a mixed-integer linear program to propose each next portfolio from these approximations. On six unbalanced three-phase feeders from the SMART-DS dataset, the search outperforms a linearized optimization-based benchmark, and the results agree across five variants of the deficiency.

0.21

Strengthening AC optimal power flow relaxation through offline bound tightening and linear approximations

eess.SY math.OC ·2026-10-23 ·Xiangxin An, Constance Crozier, Santanu S. Dey
similarity 0.57
Abstract · 15 pages, 4 figures

The alternating-current optimal power flow (ACOPF) problem is fundamental to power system operation and planning, but its nonconvexity makes globally optimal solutions of large-scale instances computationally challenging. Convex relaxations provide tractable lower bounds for assessing solution quality and supporting global optimization, although their effectiveness depends strongly on relaxation strength. This paper proposes an offline convexification and bound tightening framework for constructing strong linear programming (LP) relaxations for families of related ACOPF instances. Rather than repeating the tightening procedure for each instance, we compute variable bounds and second-order cone outer-approximation (SOC-OA) cuts offline using a demand-slack model and reuse them for subsequent instances with the same topology and admissible demand variations. Computational results on PGLib instances show that the fully offline approach achieves an average gap of $4.32\%$, compared with $3.80\%$ for the fully online approach, while achieving an average speedup of approximately $272\times$. The results demonstrate that offline convexification and bound tightening can recover most of the relaxation improvement of online tightening while significantly reducing the computational burden for repeated ACOPF evaluations.

0.32

Scalable Self-Supervised Learning for Multiphase AC-OPF in Distribution Systems with Topology Reconfiguration

eess.SY cs.LGmath.OC ·2026-08-25 ·Hoang T. Nguyen, Shaohui Liu, Reetam Sen Biswas, Varsha Pendyala, Nurali Virani +2 more
similarity 0.57
Abstract · Source code will be published following the review process

The proliferation of distributed energy resources (DERs) in distribution grids enables the active coordination of these assets to reduce costs and enable cleaner operations. Realizing this potential requires solving multiphase AC optimal power flow (AC-OPF) quickly across varying loads, DER availabilities, and topology reconfigurations, at much greater speed and scale than conventional nonlinear solvers. Learning-based surrogates can offer millisecond inference, yet existing methods target largely balanced transmission systems and do not scale to the multiphase, unbalanced, and reconfigurable nature of distribution feeders at utility scale. We present the Penalty + Sequential Linearized Feasibility Seeking (SLFS) algorithm, a self-supervised learning framework for multiphase distribution AC-OPF under switch-induced topology changes. Penalty+SLFS requires no labeled optimal solutions and trains directly from the AC-OPF objective and constraints through a differentiable fixed-point power flow solver, avoiding expensive label generation and admitting robust training procedures. Topology changes are handled efficiently using Sherman-Morrison-Woodbury updates of the admittance-matrix inverse, while an M-step Jacobian approximation accelerates differentiation through the power flow solver. At inference, SLFS repairs any infeasible predictions, providing feasibility guarantees with low computational overhead. On IEEE feeders ranging from 13 to 8,500 nodes, Penalty+SLFS achieves negligible optimality gaps and near-zero constraint violations, delivers up to three orders of magnitude speedups over IPOPT, and remains robust under large distributional shifts, demonstrating a viable path toward real-time, topology-aware AC-OPF for large-scale distribution grids.

0.23