CS Paper Radar

LatticeRank: Spacing-Ranked Consistency for Native-Grid 3D Medical Image Segmentation

Jingjia Yan, Yue Zhuo, Zhonghua Xie

cs.CV ·submitted 2026-10-20 12:08 UTC · v1
published

Abstract

Variable voxel spacing changes more than image resolution: it alters the discrete sampling lattice, tensor geometry, and anatomical evidence available to a 3D segmentation network. While conventional pipelines restore images to a canonical grid, direct-grid deployment requires the model itself to tolerate these changes. We observe that candidate grids are not exchangeable views -- a coarse grid removes more structural information than a mildly resampled one -- yet standard consistency objectives assign them equal influence. We therefore propose LatticeRank, a training-only framework that aligns candidate posteriors in physical space and allocates consistency supervision by voxel-spacing order: among endpoint-matched candidates, the auxiliary loss concentrates on the coarsest requested grid, while inference retains a single network forward with no candidate branch or ensemble. On MSD Task04, LatticeRank improves coarse-grid Extra Dice over mean consistency by 0.03436 across five seeds while meeting the prespecified reference-grid noninferiority criterion. A controlled ladder shows that grid exposure provides the largest recovery, posterior consistency adds a second gain, and spacing-ranked allocation yields the strongest direct-grid result; requested spacing thus provides a simple, model-independent ordering signal for direct-grid consistency learning.

Comment
14 pages, 6 figures. Accepted at MMM 2027

Closest papers

Nearest neighbours by meaning across the whole index.

JoVox: Joint Hierarchical Flow Matching for Lightweight Voxel Generation

cs.CV cs.GT ·2026-11-07 ·Xiangjun Tang, Jianqi Chen, Peter Wonka
similarity 0.68
Abstract

Generating high-fidelity voxels while keeping their lightweight nature remains an open problem in computer vision. Current generators are either high-fidelity but computationally heavy, or lightweight but of lower fidelity. Hierarchical methods keep the lightweight nature of voxels. However, their coarse levels, which decide where all finer cells can appear, are generated with the least information about the shape and are never revisited, so they are often plausible but wrong. Our key insight is to let finer cells take part in deciding coarse cells. To this end, we propose JoVox, a discrete flow matching framework that learns the joint distribution of all levels of the voxel hierarchy, instead of a separate distribution for each level, so that coarse cells can be predicted with finer cells already generated nearby. Within this framework, we further introduce a two-level prediction, which outputs the cells two levels finer at once instead of one level finer, halving the number of levels that the network processes and yielding voxels of higher fidelity. We also introduce an unmasking strategy that revisits early decisions once finer cells are generated and corrects inconsistencies in masked diffusion models. Our framework outperforms the baselines on both unconditional and image-conditioned voxel generation. Compared with the current state-of-the-art TRELLIS.2, we achieve 8x higher training throughput, 1/15 of the FLOPs in a forward pass, train on 4 vs. 32 GPUs, and obtain higher quality with an 11% lower Chamfer distance.

0.36

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.65
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

cs.CV cs.AI ·2026-08-30 ·Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
benchmark similarity 0.64
Abstract · 10 pages, 4 figures;

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

0.46

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.64
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

Inference-Time Orthogonal Seeding Enables Geometry-Aligned 3D Organ Segmentation for Slice-Propagation Methods

cs.CV ·2026-08-12 ·Md Rakibul Haque, Tushar Kataria, Shireen Y. Elhabian
published similarity 0.63
Abstract · 8 Pages Accepted at MLMI Workshop MICCAI 2026

Dense voxel-level annotation remains a major bottleneck in 3D medical image segmentation. Single-slice propagation methods such as Sli2Vol reduce this burden by propagating one annotated seed slice through a volume using label-free registration. However, axial-only propagation accumulates errors with distance from the seed, especially in surface-distance metrics, because it ignores coronal and sagittal evidence and therefore underuses the 3D information available in CT/MRI volumes. To better leverage volumetric geometry, we study how key training and inference choices affect slice-propagation models, including single-axis versus multi-axis label-free registration, single-seed versus multi-seed propagation, and orthogonal seed configurations. Instead of propagating from a single axial seed, we use three orthogonal seeds---one axial, one coronal, and one sagittal---and fuse their propagated labels with a simple label-free rule. Our results show that the training paradigm has limited impact: an axially trained network applied to off-axis seeds captures nearly all the improvement, while explicit three-axis training adds little. Instead, performance is driven by inference-time seed geometry, especially orthogonality rather than the number of annotated slices, as a budget-matched three-axial control provides no benefit and can even degrade performance. On a multi-organ CT cohort, orthogonal seeding with the axial Sli2Vol backbone improves Dice by 21.9%, Normalized Surface Dice by 25.5%, and reduces Average Hausdorff Distance by 53.5% over the single-axis baseline.

0.54

Where to Look Matters: Rethinking Sub-Volume Sampling in 3D Medical Self-supervised Learning

cs.CV ·2026-10-09 ·Junkai Liu, Le Zhang
publishedcode/data similarity 0.63
Abstract · NeurIPS 2026. Project page: https://volumeprobe.github.io/

Self-supervised learning on 3D medical images commonly relies on random sub-volume sampling during pretraining. However, random cropping implicitly treats all spatial regions as equally worth observing, despite anatomical priors and spatial redundancy that make regions inherently unequal in their value for representation learning. To this end, we first show through controlled crop-quality manipulations that better sub-volumes lead to better downstream transfer, revealing the observation policy as an overlooked bottleneck in 3D medical SSL. Motivated by this finding, we revisit sub-volume sampling as a where-to-look problem. We propose VolumeProbe, a plug-and-play framework that replaces random cropping with an offline coarse-to-fine probe bank guided by anatomy-awareness, informativeness, and diversity. We instantiate VolumeProbe as a lightweight Lite variant using geometric and image-statistical cues, and a diagnostic Feat variant using frozen visual features, to examine whether lightweight volume-intrinsic priors suffice or richer semantic cues reliably provide additional value. Extensive experiments across multiple 3D medical SSL backbones and downstream tasks demonstrate that VolumeProbe-Lite consistently improves transfer performance over random sampling. Mechanistic analyses further link these gains to more anatomically plausible and informative observations, reduced spatial redundancy, more efficient learning dynamics, and more structured representations.

0.22

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

cs.CV ·2026-11-06 ·Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
top venue similarity 0.63
Abstract · 32 pages, 6 figures, Accepted to NeurIPS 2026 ED Track

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

0.50

Fed-ADApt: Federated Anytime Depth Adaptation for Resource-Aware Medical Image Segmentation

cs.CV ·2026-10-02 ·Abhijeet Parida, Zhifan Jiang, Pooneh Roshanitabrizi, Austin Tapp, Maria J. Ledesma-Carbayo +4 more
published similarity 0.63
Abstract · Accepted to The 4th International Conference on Federated Learning Technologies and Applications (FLTA 2026)

Federated learning (FL) enables collaborative training of medical image segmentation models without sharing raw patient data, yet existing approaches assume a homogeneous compute budget across institutions, limiting participation of low-resource sites. We propose Fed-ADApt, a depth-adaptive federated framework for UNet-based segmentation that jointly addresses low-compute training and inference. Fed-ADApt integrates multi-depth supervision with hierarchical depth-wise aggregation, allowing each site to train according to its local compute budget while contributing to a global model that supports dynamic depth selection at deployment. We evaluated Fed-ADApt on multi-site 2D retinal fundus disc segmentation and 3D brain tumor segmentation. Across both tasks, federated collaboration substantially improves robustness under domain shift. Fed-ADApt matched the full-resource FedAvg performance in 3D and achieved competitive 2D performance with a 4.7% average Dice reduction, while reducing average inference cost by 19.5% in 3D and 34.5% in 2D and substantially reducing training cost by 98% at the most constrained sites. Importantly, Fed-ADApt enables low-resource institutions that cannot train full-capacity models to participate in federations while maintaining competitive global performance under a favorable accuracy to efficiency trade-off. By considering training and inference compute budgets, Fed-ADApt provides a practical and equitable solution for federated medical image segmentation across heterogeneous clinical and edge-enabled imaging environments.

0.22