CS Paper Radar

A Plantwide Simulation Library for Control-Oriented Design: Analytical and Data-driven Use Cases

Kyle Territo, Luis A. Briceno-Mena, Jose A. Romagnoli

eess.SY ·submitted 2026-10-21 16:14 UTC · v1

Abstract

Control structures and operability indices for plantwide processes are developed and compared on fixed simulated flowsheets, and the configuration of a study is rarely reported in a form that another group can reproduce. In this contribution, plantbench, a library of plantwide process simulations in which the design, the controller tuning and the instrumentation of a plant are declared as hashed plain-data configurations, is presented. On a heat-integrated reactor--separator--recycle plant with an open-loop unstable reactor, a heuristic plantwide control design prices four heat-exchanger networks (HENs) by the least damping ratio of the linearized closed loop, and 2016 closed-loop runs over networks, tuning, analyzer deadtime and upsets test that ranking. Results show that the damping ratio orders the networks as the runs do with the network that recovers the most heat reaching 0.013 against 0.157 for the selected one and cycling under a throughput increase, but that it is a weak detector of which operation will oscillate. At the recall of a random forest on the first 100 min after an upset, 60 of 82 limit cycles, a damping-ratio threshold raises 173 false alarms against 5. The integral time of the temperature loop, to which the damping ratio is nearly insensitive, decides in part whether the plant holds an operating point.

Comment
6 pages, 3 figures, Submitted to the American Control Conference (ACC) 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-informed neural control of heat flow rate in a counter-flow heat exchanger: modeling, identification and experimental validation

eess.SY ·2026-10-04 ·Konstantinos Skantzikas, Emmanuel Witrant, Bojan Mavkov
similarity 0.54
Abstract

The advanced operation of heat exchangers plays a critical role in the development of efficient and sustainable multivector energy systems. This paper proposes a hybrid physics-informed and data-driven framework for the analysis, identification, and regulation of transient heat transfer in counter-flow heat exchangers. A parameterized physical model combines classical heat-transfer relations with transport equations to capture convective propagation, transport-induced delays, and nonlinear effects associated with flow-rate variations. The heat-transfer coefficient is identified from experimental data, enabling the characterization of flow-dependent heat-transfer dynamics over a broad operating range. The identified model is then used to develop a hierarchical real-time control strategy. An inner loop regulates the volumetric flow rate using a high-order data-driven linear model, while an outer loop regulates the exchanged heat power using a machine-learning controller initially trained on the physical model and subsequently refined with experimental data. Experimental results demonstrate accurate reproduction of transient heat-transfer dynamics and effective heat-flow-rate regulation under varying thermal boundary conditions (identification fit above 94\% in normalized root-mean-square error and total variation of the flow rate reduced by half compared to a proportional-integral controller). The proposed framework combines physical interpretability with data-driven adaptation for the analysis and real-time operation of dynamic heat-transfer systems.

0.29

OperAItor: An Agentic Framework for Fault-Tolerant Operation of Chemical Processes

eess.SY cs.AI ·2026-11-03 ·Javal Vyas, Mehmet Mercang{ö}z
benchmarkcode/data similarity 0.52
Abstract

OperAItor, an open-source framework for developing and evaluating large language model agents for supervisory fault management in chemical processes. The framework is demonstrated on a dynamic reactor-distillation process representing isopropanol dehydrogenation, with physically based thermodynamics and modified reaction kinetics to permit liquid-phase operation. The process is represented by a 113-variable differential-algebraic model and operates at a nominal feed rate of 100kmol/h, producing approximately 4t/h of acetone. The simulated plant includes 8 PI control loops, 22 process alarms, 5 duty-standby pump trains, and 11 independent safety instrumented functions. The agent architecture integrates multivariate statistical process monitoring, fault diagnosis, knowledge-graph retrieval, action planning, and supervisory action generation. Five action-validation configurations are investigated, comprising operation without validation, an LLM-based judge, digital-twin simulation, and deterministic admissibility checks with and without consequence projection. The framework is evaluated using four LLMs across 20 scenarios involving single and multiple simultaneous faults. Without agent intervention, 18 scenarios result in plant stops, corresponding to an economic loss of $399,000 relative to fault-free operation under the assumed benchmark economics. For GPT-5 nano, Qwen3 8B, and Mistral 7B, validated agent configurations reduce the number of stops to 5-8 and recover $265,000 of the loss. The study provides a reproducible benchmark for comparing agent architectures, language models, and action-validation methods for supervisory fault management in chemical processes.

0.33

Control-Oriented Modeling of Heat Exchangers with Improved Low-Flow Dynamics

eess.SY ·2026-10-30 ·Noah Hofmann, Stefan L. Hölzl, Robert Bauer, Martin Steinberger
similarity 0.50
Abstract · 6 pages

Existing low-order models of heat exchangers can lose dynamic accuracy at low flow rates, when fluid residence times become significant. This paper proposes two control-oriented models that improve the low-flow performance. The first extends a finite-volume formulation with the first spatial temperature moment, whereas the second uses Chebyshev--Lobatto collocation. Both capture the coupled heat-transfer and transport dynamics and improve the performance when the system behavior is dominated by the inlet-temperature dynamics. At equal state dimension, comparisons with a high-order reference show more accurate delayed outlet-temperature responses while retaining steady-state accuracy.

0.22

Adaptive control of pool-type research nuclear reactors: theory limits, pragmatic actuation constraints, and realized performance and adaptation

eess.SY math.OC ·2026-10-05 ·Dimitrios Pylorof, Linyu Lin
similarity 0.49
Abstract

Adaptive control is attractive for nuclear reactors expected to operate predictably with extensive automation or bounded autonomy under dynamic electric and nonelectric demands, even as reactor and actuator characteristics depart from their nominal values. Standard adaptive control results, however, assume fixed matched dynamics and an input applied as computed. In this work we evaluate a recent model reference adaptive control with linear quadratic regulation (MRAC-LQR) construction on the nonlinear point-kinetics model of Purdue University Reactor Number One (PUR-1), with a moving physical reference, nonlinear rod worth, rate and travel limits, quantization, deadband, and optional power-only state reconstruction. An exact sampled decomposition separates matched adaptation from observer, command processing, actuator realization, independent reactivity, and unmatched-dynamics residuals. Numerical results emphasize compatible reference trajectories, plant parameter variation, response to unexpected rod motion, and actuator duty. Across sampled plants, one unchanged nominal design yields closely aligned responses through adaptively calculated, plant-dependent actuation histories, illustrating both the premise and the theory limits of adaptation at a pool-reactor scale that can support follow-on experimental verification and progression toward higher-consequence nuclear applications.

0.25

Co-designing a Layered Control Architecture

eess.SY math.OC ·2026-10-14 ·Chris Verhoek, Charis Stamouli, George J. Pappas, Nikolai Matni
similarity 0.49
Abstract · 19 pages, extended version

Layered control architectures (LCAs) are ubiquitous in complex engineering systems. However, in practice they are largely designed ad hoc and mostly dictated by the experience of the designer. This is because there is currently no systematic and practically applicable theory available to holistically design LCAs. Hence, systematically reasoning about the optimality, stability, and feasibility of the LCA design is not possible. We set a first step toward such a theory by presenting a framework for co-designing a two-layer LCA for a linear time-invariant plant. The resulting co-design problem optimizes over architectural design variables (e.g., reduced order model dimension and sampling ratio between the layers) and tuning-based design variables (e.g., the numerical values of the feedback gain or the matrices of the reduced order model), all subject to constraints that ensure stability, feasibility, and compute properties of the closed-loop LCA. The proposed formulation allows to make informed tradeoffs along the Pareto front traced over different axes of optimality, e.g., speed, accuracy or computational effort. We demonstrate the effect of making various tradeoffs in a simple numerical example.

0.45

Multi-time-scale Control of Power Systems

eess.SY math.OC ·2026-10-26 ·Emiliano Dall'Anese, John W. Simpson-Porco, Florian Dorfler, Saverio Bolognani, Sairaj Dhople
survey similarity 0.49
Abstract · Submitted for publication

The power grid has been dominated by large synchronous generators and clearly separated control layers. Today, power-electronics energy conversion interfaces are rapidly being deployed calling for another look at system-level control hierarchies. This article examines how multi-time-scale modeling, feedback control, and feedback optimization can help reinterpret the traditional organically grown hierarchy of primary control, automatic generation control, and economic dispatch, and enable new approaches for control of contemporary power systems. Beginning with an overview of power system models and conventional operational practices, the article develops connections to modern control architectures that can coordinate heterogeneous resources, account for operational constraints, and exploit faster actuation without overlooking first-principles physics.

0.28

Model-Free PID Tuning by Step-Response Inspection

eess.SY eess.SP ·2026-09-14 ·Daniel Pachner, Pavel Otta, Jiří Dostál, Vladimír Havlena
unusual similarity 0.49
Abstract · 12 pages, 4 figures, ready for submission

Industrial PID loops are still tuned by hand: step the setpoint, look at the response, change a gain. This paper turns that procedure into an algorithm, SPIN, for Step-response Phase-portrait INspection. From a single closed-loop step response we form three phase portraits of the control deviation and count how many times each trajectory winds around its settling point. The counts are dimensionless and independent of the step size and of the clock. They show which channel is under-damped: integral, proportional, or derivative. A triangular rule reads the three counts, cutting the gain of the one band whose fault is certain and raising that of every band the same test shows to be within its limit. No model is identified and no optimization is solved. The iteration is deterministic and its gains stay inside a fixed box. Because a ringing count is itself the evidence that the loop is in the regime where cutting that band's gain reduces the count, the iteration settles into a cycle at the edge of the well-damped set. It needs no excitation beyond a routine setpoint step, so it can run on a process in operation, and it may start from arbitrary gains, including destabilizing ones. SPIN assumes a stable, self-regulating process whose gain and phase both fall with frequency, which covers the lag-plus-dead-time models common in process control, and a controller from the nested family $\mathrm{I} \subset \mathrm{PI} \subset \mathrm{PID}$ with integral action present. We validate it on a battery of process-typical plants with one fixed step size and one set of dimensionless constants throughout. Every decision is visible: the operator sees what the algorithm sees. A reference implementation and an interactive demonstration are public.

0.28

Techno-Economic Boundary Analysis of Small Modular Reactor Cogeneration for Hyperscale Data Center IT and Cooling Loads

eess.SY ·2026-08-11 ·Honglin Li, Buxin She, Jie Zhang
similarity 0.48
Abstract

Hyperscale data centers are adding firm, high-utilization demand faster than grids can serve it, renewing interest in colocating them with small modular reactors. Such a plant could earn revenue in two ways, selling low-carbon power and diverting steam to absorption chillers that serve a cooling load accounting for 20-40% of facility electricity use, but neither revenue stream has been priced across the conditions that must coincide. Here we co-optimize reactor dispatch, steam extraction, absorption cooling and grid exchange hourly for a 200 MW$_\mathrm{e}$ data center in the Electric Reliability Council of Texas (ERCOT) region, across 109 runs spanning capital, market, policy, financing and cooling efficiency. At 2023 mid-range reactor capital, the nuclear configurations cost 49-62% more than grid supply even with the Section 45Y production tax credit. The viable region opens near \$5,000 kW$_\mathrm{e}^{-1}$, and nth-of-a-kind capital makes them 77-89% cheaper in 2023, though between parity and 34% more expensive in the low-price 2024 market. A carbon price of \$53-64 tCO$_2^{-1}$ closes the mid-range gap under hourly export crediting. Absorption cooling is dispatched in response to hourly electricity prices and supplies 38% of annual cooling, at an added cost of \$9.2 million yr$^{-1}$ relative to the reactor-only plant; that gap closes at an installed absorption cost of \$60 kW$_\mathrm{c}^{-1}$ at baseline efficiency and \$570 kW$_\mathrm{c}^{-1}$ on a legacy-efficiency campus, against surveyed commercial prices of \$450-1,200 kW$_\mathrm{c}^{-1}$. Together these results delineate the capital, market and policy conditions under which colocated reactor cogeneration is competitive with grid procurement, and the range over which each condition moves the outcome.

0.04