CS Paper Radar

Control-Oriented Modeling of Heat Exchangers with Improved Low-Flow Dynamics

Noah Hofmann, Stefan L. Hölzl, Robert Bauer, Martin Steinberger

eess.SY ·submitted 2026-10-30 07:31 UTC · v1

Abstract

Existing low-order models of heat exchangers can lose dynamic accuracy at low flow rates, when fluid residence times become significant. This paper proposes two control-oriented models that improve the low-flow performance. The first extends a finite-volume formulation with the first spatial temperature moment, whereas the second uses Chebyshev--Lobatto collocation. Both capture the coupled heat-transfer and transport dynamics and improve the performance when the system behavior is dominated by the inlet-temperature dynamics. At equal state dimension, comparisons with a high-order reference show more accurate delayed outlet-temperature responses while retaining steady-state accuracy.

Comment
6 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-informed neural control of heat flow rate in a counter-flow heat exchanger: modeling, identification and experimental validation

eess.SY ·2026-10-04 ·Konstantinos Skantzikas, Emmanuel Witrant, Bojan Mavkov
similarity 0.70
Abstract

The advanced operation of heat exchangers plays a critical role in the development of efficient and sustainable multivector energy systems. This paper proposes a hybrid physics-informed and data-driven framework for the analysis, identification, and regulation of transient heat transfer in counter-flow heat exchangers. A parameterized physical model combines classical heat-transfer relations with transport equations to capture convective propagation, transport-induced delays, and nonlinear effects associated with flow-rate variations. The heat-transfer coefficient is identified from experimental data, enabling the characterization of flow-dependent heat-transfer dynamics over a broad operating range. The identified model is then used to develop a hierarchical real-time control strategy. An inner loop regulates the volumetric flow rate using a high-order data-driven linear model, while an outer loop regulates the exchanged heat power using a machine-learning controller initially trained on the physical model and subsequently refined with experimental data. Experimental results demonstrate accurate reproduction of transient heat-transfer dynamics and effective heat-flow-rate regulation under varying thermal boundary conditions (identification fit above 94\% in normalized root-mean-square error and total variation of the flow rate reduced by half compared to a proportional-integral controller). The proposed framework combines physical interpretability with data-driven adaptation for the analysis and real-time operation of dynamic heat-transfer systems.

0.29

A Plantwide Simulation Library for Control-Oriented Design: Analytical and Data-driven Use Cases

eess.SY ·2026-10-21 ·Kyle Territo, Luis A. Briceno-Mena, Jose A. Romagnoli
similarity 0.50
Abstract · 6 pages, 3 figures, Submitted to the American Control Conference (ACC) 2027

Control structures and operability indices for plantwide processes are developed and compared on fixed simulated flowsheets, and the configuration of a study is rarely reported in a form that another group can reproduce. In this contribution, plantbench, a library of plantwide process simulations in which the design, the controller tuning and the instrumentation of a plant are declared as hashed plain-data configurations, is presented. On a heat-integrated reactor--separator--recycle plant with an open-loop unstable reactor, a heuristic plantwide control design prices four heat-exchanger networks (HENs) by the least damping ratio of the linearized closed loop, and 2016 closed-loop runs over networks, tuning, analyzer deadtime and upsets test that ranking. Results show that the damping ratio orders the networks as the runs do with the network that recovers the most heat reaching 0.013 against 0.157 for the selected one and cycling under a throughput increase, but that it is a weak detector of which operation will oscillate. At the recall of a random forest on the first 100 min after an upset, 60 of 82 limit cycles, a damping-ratio threshold raises 173 false alarms against 5. The integral time of the temperature loop, to which the damping ratio is nearly insensitive, decides in part whether the plant holds an operating point.

0.26

Model Predictive Control for Dynamic Hydraulic Balancing in Building Radiator Heating Systems: Modeling, Design, and Experimental Validation

eess.SY math.OC ·2026-09-08 ·Erfan Shakhesi, Maurice Heemels, Paula Chanfreut
similarity 0.50
Abstract

Hydronic radiator systems are among the most widely used heating systems in buildings. In the literature, radiator heat outputs are often assumed to be independent of one another and arbitrarily adjustable in time when designing controllers. However, in practice, radiators are supplied by one or multiple common heat sources and are hydraulically coupled through the water circulation system. Maintaining occupant comfort in multi-zone buildings therefore requires not only an appropriate supply temperature but also proper hydraulic balancing to distribute the available water flow according to the heating demand of each zone. To this end, we develop a grey-box thermal model that captures the hydraulic interactions among radiators and the effects of radiator valves, circulation pumps, and heat sources. In a real building, we show that accounting for hydraulic interactions reduces the root mean square error (RMSE) between the measured and modeled zone temperatures by approximately 11% compared with a model that neglects these interactions. Additionally, we integrate the developed model into a model predictive control (MPC) framework for dynamic hydraulic balancing that jointly optimizes valve openings and the supply temperature to maintain thermal comfort in each zone while reducing energy consumption. Through both real-world experiments and numerical case studies, we demonstrate that, compared with existing MPC formulations that neglect hydraulic interactions or do not control radiator valves, the proposed MPC reduces comfort-range violations by at least 27% while requiring a similar or even lower cumulative supply temperature.

0.40

A Mixed $H_{\infty}$--Passivity Approach for Leveraging Heat-Pump-Connected District Heating Systems as Frequency Support in Electric Power Systems

eess.SY ·2026-10-29 ·Xinyi Yi, Ioannis Lestas
code/dataunusual similarity 0.48
Abstract

Heat-pump (HP)-connected district heating systems (DHSs) can support grid frequency by rapidly modulating HP electrical consumption while accommodating the resulting heat imbalance. Thermal-state-informed HP control improves EPS--DHS coordination, but introduces slower DHS dynamics and heat-side disturbance propagation at the electrical interface on the time scale of secondary frequency control. This paper formulates the regulated DHS as a grid-facing dynamic port and develops a mixed $H_\infty$--passivity framework for disturbance-independent temperature regulation while preserving a clean electrical response during secondary frequency control. Sufficient conditions guarantee local asymptotic stability of the EPS--HP--DHS interconnection across primary frequency control, secondary frequency control, and DHS regulation. These stability conditions are integrated with multi-channel $H_\infty$ attenuation of DHS-state-dependent electrical dynamics, heat-disturbance propagation, and DHS-regulation errors, yielding a tractable convex LMI program for controller synthesis. Cross-model validation deploys controllers synthesized on control-oriented EPS--DHS models, without retuning, on an open-source electromechanical IEEE 39-bus model coupled with four high-fidelity finite-volume DHS models retaining thermal transport, storage, and heat-loss dynamics. The resulting controller improves EPS--DHS coordination without compromising the grid-facing electrical response.

0.40

Model Predictive Control of Heating Systems via Koopman-Operator Bilinearization

eess.SY ·2026-11-02 ·Paula Chanfreut, Erfan Shakhesi, Mircea Lazar, Maurice Heemels
similarity 0.48
Abstract

Hydronic heat emitters are widely used in buildings, but their control is challenging due to nonlinear dynamics, arising from both the heat transfer in each emitter and the hydraulic coupling among those that share a circulating pump. These nonlinearities are often simplified or neglected in the literature. In this paper, we use Koopman theory to make the resulting model more tractable for control. In particular, we propose an input reparameterization and construct an infinite-dimensional set of observables that yields an exact bilinear representation of the system in the chosen lifted space. We then show that truncating the infinite-dimensional representation leads to bounded approximation errors that decrease as the truncation order increases, as well as bounded trajectory deviations over a finite horizon. The resulting bilinear model is incorporated into a model predictive control (MPC) framework to provide thermal comfort in multi-zone buildings while reducing energy use. Using a numerical case study of a five-story building with 20 zones, we show that the proposed Koopman-based MPC achieves a realized performance cost close to that of nonlinear MPC with faster solve times, and outperforms MPC formulations based on time-invariant and time-varying linearizations.

0.27

Transient multimode heat transfer of an industrial automated tape laying process under rapidly changing conditions

cs.RO ·2026-08-26 ·Bernhard Rameder, Hubert Gattringer, Andreas Müller, Ronald Naderer
publishedunusual similarity 0.47
Abstract · 20 pages

This work presents a transient heat-transfer model of an industrial automated tape laying (ATL) process designed to overcome the limitations of conventional thermal models in composite manufacturing. The model solves the heat-conduction equation with coupled advection, conduction, convection, and radiation. A key innovation is the implementation of an analytical view factor approach that accounts for finite emitter and tape widths, thereby correcting systematic overestimations of radiative heat flux inherent in 1.5D simplifications. Furthermore, a local convection assessment incorporates mixed convection effects characterized by the Richardson number, ensuring accuracy across a wide range of process speeds. The ATL system is represented by two interacting subsystems: the moving tape substrate and the infrared heat sources. The tape is discretized using a two-node model that resolves the physical phase shift between the heated and monitored surfaces. Numerical stability under high dynamics is ensured by a monolithic solution strategy using a high-order implicit integration scheme. Model predictions were validated on an industrial ATL line, demonstrating an overall deviation of only 1.08% (NRMSE) under rapid velocity and current modulations. This framework provides a high-fidelity, physics-based foundation for thermal state estimation, supporting consistent in-situ consolidation and improved part quality.

0.42

Cova-PINN: Cross-Domain Conservation Physics-Informed Neural Network for Fluid-Solid Conjugate Heat Transfer in Complex Geometries

cs.LG physics.flu-dyn ·2026-10-08 ·Weizheng Zhang, Xunjie Xie, Hao Pan, Lin Lu
similarity 0.47
Abstract

Multi-domain physics-informed neural networks (PINNs) flexibly model medium-specific representations to solve fluid--solid conjugate heat transfer (CHT). However, standard multi-domain PINNs enforce governing equations and interface conditions on separately sampled domain supports, which can yield plausible temperature fields but inaccurate end-to-end energy transfer and outlet temperatures. We propose Cova-PINN, a multi-domain PINN framework that aligns conservation support with thermal interaction paths in complex geometries. Cova-PINN jointly optimizes cross-domain composite control-volume balances at the local scale and paired-wall closure at the global exchanger scale. We evaluate Cova-PINN on four triply periodic minimal surface (TPMS) heat exchangers and a geometrically distinct DualMS design against CHT-specific, optimization-oriented, and complex-geometry PINN baselines under a common protocol. Relative to the closest baseline, MUSA-PINN-CHT, Cova-PINN reduces average outlet-temperature and device-level closure errors across the four TPMS topologies by $37.7\%$ and $60.2\%$, respectively, while also improving full-field and heat-duty accuracy, with consistent gains on DualMS.

0.25

Control design for a class of nonlinear convection-reaction systems with storage effects and relative degree one

eess.SY ·2026-10-15 ·Jens Wurm, Frank Woittennek
similarity 0.46
Abstract · 14 pages, 7 figures

This article addresses the control design for systems of several convection-reaction equations distributively coupled to a reaction equation. In typical applications, input and output are associated exclusively with the convection-reaction subsystems. Along the common characteristics of the transport processes, the system can be reduced to a single delayed evolutionary ODE. Based on the latter representation, an inversion-based feedforward control is proposed, whose properties depend on the coupling structure of the original system. While the relative degree of the output is zero in many cases, a relative degree of one is of particular interest for practical applications. To compensate for uncertainties and disturbances, the feedforward control is extended by a tracking controller with a predictor based on the transformed system to account for the resulting delays.

0.26