CS Paper Radar

Transient multimode heat transfer of an industrial automated tape laying process under rapidly changing conditions

Bernhard Rameder, Hubert Gattringer, Andreas Müller, Ronald Naderer

cs.RO ·submitted 2026-08-26 07:37 UTC · v1
publishedunusual

Abstract

This work presents a transient heat-transfer model of an industrial automated tape laying (ATL) process designed to overcome the limitations of conventional thermal models in composite manufacturing. The model solves the heat-conduction equation with coupled advection, conduction, convection, and radiation. A key innovation is the implementation of an analytical view factor approach that accounts for finite emitter and tape widths, thereby correcting systematic overestimations of radiative heat flux inherent in 1.5D simplifications. Furthermore, a local convection assessment incorporates mixed convection effects characterized by the Richardson number, ensuring accuracy across a wide range of process speeds. The ATL system is represented by two interacting subsystems: the moving tape substrate and the infrared heat sources. The tape is discretized using a two-node model that resolves the physical phase shift between the heated and monitored surfaces. Numerical stability under high dynamics is ensured by a monolithic solution strategy using a high-order implicit integration scheme. Model predictions were validated on an industrial ATL line, demonstrating an overall deviation of only 1.08% (NRMSE) under rapid velocity and current modulations. This framework provides a high-fidelity, physics-based foundation for thermal state estimation, supporting consistent in-situ consolidation and improved part quality.

Comment
20 pages
Journal ref
Composites Part A: Applied Science and Manufacturing (2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Control-Oriented Modeling of Heat Exchangers with Improved Low-Flow Dynamics

eess.SY ·2026-10-30 ·Noah Hofmann, Stefan L. Hölzl, Robert Bauer, Martin Steinberger
similarity 0.47
Abstract · 6 pages

Existing low-order models of heat exchangers can lose dynamic accuracy at low flow rates, when fluid residence times become significant. This paper proposes two control-oriented models that improve the low-flow performance. The first extends a finite-volume formulation with the first spatial temperature moment, whereas the second uses Chebyshev--Lobatto collocation. Both capture the coupled heat-transfer and transport dynamics and improve the performance when the system behavior is dominated by the inlet-temperature dynamics. At equal state dimension, comparisons with a high-order reference show more accurate delayed outlet-temperature responses while retaining steady-state accuracy.

0.22

Physics-informed neural control of heat flow rate in a counter-flow heat exchanger: modeling, identification and experimental validation

eess.SY ·2026-10-04 ·Konstantinos Skantzikas, Emmanuel Witrant, Bojan Mavkov
similarity 0.47
Abstract

The advanced operation of heat exchangers plays a critical role in the development of efficient and sustainable multivector energy systems. This paper proposes a hybrid physics-informed and data-driven framework for the analysis, identification, and regulation of transient heat transfer in counter-flow heat exchangers. A parameterized physical model combines classical heat-transfer relations with transport equations to capture convective propagation, transport-induced delays, and nonlinear effects associated with flow-rate variations. The heat-transfer coefficient is identified from experimental data, enabling the characterization of flow-dependent heat-transfer dynamics over a broad operating range. The identified model is then used to develop a hierarchical real-time control strategy. An inner loop regulates the volumetric flow rate using a high-order data-driven linear model, while an outer loop regulates the exchanged heat power using a machine-learning controller initially trained on the physical model and subsequently refined with experimental data. Experimental results demonstrate accurate reproduction of transient heat-transfer dynamics and effective heat-flow-rate regulation under varying thermal boundary conditions (identification fit above 94\% in normalized root-mean-square error and total variation of the flow rate reduced by half compared to a proportional-integral controller). The proposed framework combines physical interpretability with data-driven adaptation for the analysis and real-time operation of dynamic heat-transfer systems.

0.29

Iterative Learning Control of the Cooling Rate in a Dual-Laser Powder Bed Fusion Process

eess.SY ·2026-09-23 ·Lauren Bogo, Adam Clare, Dominic Liao-McPherson
published similarity 0.43
Abstract · 7 pages, 9 figures, 2 tables. Accepted to the 2026 IEEE Conference on Control Technology and Applications (CCTA)

The thermal history of the melt pool in laser powder bed fusion (LPBF) additive manufacturing processes governs the solidification microstructure and the mechanical properties of the resulting 3D-printed parts. Dual-laser systems offer additional degrees of freedom to control the cooling profile by reheating material behind the melt pool, but calibrating process parameters is challenging due to the complex physics of the process. We present an optimization-based iterative learning controller that determines optimal power, velocity, and offset settings by judiciously combining simulations and experiments: the model supplies search directions while feedback obtained from experiments on the real plant corrects for parameter errors, enabling convergence despite model inaccuracies. The approach is validated in simulation using a high-fidelity thermal model as a plant surrogate, with deliberate mismatches in absorption coefficient, latent heat treatment, and powder-bed effective conductivity between plant and model. Results show that the controller drives the plant cost down by over an order of magnitude and reaches a tight band of low-cost solutions across seeds, while model-only feedforward optimization stalls at a substantially higher plant cost despite appearing to converge on the surrogate.

0.37

Generative Design of Liquid-Cooling Channels for Thermal Management of 2.5D and 3D Integrated Advanced Packaging

eess.SY ·2026-08-24 ·Michael Acquah, Zheng Liu
similarity 0.40
Abstract · 29 pages, 5 figures

High-power multi-chip packages require increasingly effective cooling as intensive heat is generated within a limited package area. This work presents a physics-guided generative design framework for liquid-cooling channel topology optimization in a 2.7 kW multi-chip package containing two high-power graphics processing units (GPUs) and one central processing unit (CPU). A conditional diffusion model generates symmetric channel layouts using maximum GPU temperature, GPU temperature spread, and pressure drop as performance targets. Generated designs undergo connectivity and dead-end-branch screening and are evaluated using a calibrated reduced-order thermal-fluids model. Based on 5,000 generated layouts, the multi-objective analysis identified the optimal design for thermal properties, with estimated maximum GPU temperature of 70.30 degree Celsius, GPU temperature spread of 24.90 degree Celsius, and pressure drop of 89.72 kPa. Compared to a conventional reference topology, the optimal design reduced the maximum GPU temperature, temperature spread, and pressure drop by 33.6%, 52.5%, and 72.8%, respectively. High-fidelity three-dimensional conjugate heat-transfer simulation in OpenFOAM estimated a maximum GPU temperature of 66.70 degree Celsius and a pressure drop of 92.1 kPa, showing only differences of 8.6% in temperature rise and 2.6% in pressure drop. The results demonstrate that physics-guided generative design based on the reduced-order model can efficiently discover unconventional cooling channel architectures while reducing reliance on repeating computationally expensive simulation.

0.46

Temperature-Dependent Multiphysics Modeling of Additive Friction Stir Deposition Using Multi-Task Coupled Physics-Informed Neural Networks

cs.CE physics.comp-ph ·2026-10-02 ·Dhrubajyoti Gupta, Nikhil Gotawala, Raghav Gnanasambandam, Rohit Kannan, Jian Yu +2 more
benchmark similarity 0.40
Abstract · 14 pages, 12 figures, 7 tables

Additive friction stir deposition (AFSD) involves coupled thermal and material-flow fields governed by frictional heating, plastic deformation, and tool-imposed boundary conditions. High-fidelity finite-volume methods (FVMs) can resolve these fields but are computationally expensive, while constant-property approximations can distort the predicted thermo-mechanical response. This work develops a steady-state multi-task coupled physics-informed neural network (MCoPINN) to predict three-dimensional temperature and material-flow fields while reconstructing temperature-dependent thermal conductivity, density, and specific heat from sparse property measurements. A theoretical analysis decomposes prediction error into property reconstruction and neural field-solver contributions and characterizes the discrepancy associated with constant-property models. A controlled one-dimensional nonlinear-conduction study evaluates property reconstruction under sparse measurements. The framework is then evaluated for AFSD against a temperature-dependent FVM benchmark and experimental thermocouple measurements. MCoPINN reproduces the reference thermal and material-flow fields and reduces average temperature root-mean-square error from 50.13 K for the constant-property CoPINN to 30.28 K across four traverse speeds. MCoPINN requires approximately 8.5 hours of training per condition, compared with 52 hours for the FVM benchmark. These results demonstrate computationally efficient, physics-coupled prediction with temperature-dependent material properties.

0.34

A Composable AI-Accelerated Iterative Solver for 3D-IC Thermal Modeling

cs.LG ·2026-10-01 ·Yixing Li, Jiahang Zhou, Zhiyu Zeng, Xin Ai
similarity 0.39
Abstract

Accurate thermal analysis of heterogeneous 2.5D/3D-IC packages is essential yet computationally prohibitive. A single full-package FEM simulation can take hours, while AI-based surrogates treat the entire stack as a monolithic prediction target and must be retrained whenever the die count or topology changes. To address this limitation, this work proposes Domain-Decomposed AI-Accelerated Iterative Solver for Thermal Analysis (DAIST), a composable thermal solver that decomposes the global package simulation into block-level subdomain problems, replaces subdomain solvers with neural operators, and couples them through iterative exchanges of interfacial temperature and heat flux. This local-to-global architecture eliminates the topology lock-in of monolithic models: block-level neural operators can be directly reused in unseen package assemblies without retraining. The iterative coupling strategy further provides a controllable accuracy-runtime tradeoff, where the iteration budget can be adjusted to trade accuracy for runtime. Evaluated on a multi-chiplet system and an advanced packaging system, DAIST achieves up to $178\times$ speedup over traditional FEM solvers with mean temperature errors of 0.068% and 0.323%, respectively, while demonstrating cross-topology reuse of block-level models across structurally distinct package assemblies.

0.06

Localized Thermal Management of Induction-Heated Microrobots for Hyperthermia Applications

eess.SY ·2026-10-06 ·Advika Balaji, Miguel F. Arevalo-Castiblanco, Aaron T. Becker
unusual similarity 0.39
Abstract · 6 pages, 10 figures, Submitted to ICRA 2026

Induction-heated microrobots face a fundamental thermal management challenge: the alternating magnetic fields required for localized hyperthermia simultaneously generate parasitic ohmic heating within the actuation coils. Conventional cooling approaches can fail because conductive cooling structures placed near the coil can couple to the time-varying field, generating additional electromagnetic losses. This paper addresses this architectural limitation by evaluating two liquid-cooling frameworks designed to isolate the electromagnetic workspace: an indirect configuration utilizing an external copper water block, and a direct architecture routing coolant internally through a hollow helical coil. Evaluated over a 100~s window with multi-point thermocouple telemetry, the indirect water-block configuration failed due to secondary inductive coupling with the block itself, acting as an unintended susceptor that drove the block temperature to an extreme peak of 805$^{\circ}$C. In contrast, the direct internal cooling architecture successfully extracted ohmic losses at the source, sustaining a localized ablation tip temperature of 63.4$^{\circ}$C while strictly restricting surrounding fluid and boundary surfaces below defined thresholds of 33.9$^{\circ}$C and 37.6$^{\circ}$C, respectively. These results establish coil-level fluidic integration as a key design principle for thermally isolated microrobot actuation and provide a hardware foundation for future spatially controlled hyperthermia.

0.29

Stacked Fluid Metasurfaces: Mutual-Coupling-Aware Modeling and Optimization

eess.SP ·2026-09-25 ·Giovanni Iacovelli, Chandan Kumar Sheemar, Symeon Chatzinotas
similarity 0.37
Abstract

Stacked intelligent metasurfaces process the transmitted field layer by layer, and fluid antennas make the position of every radiator a design variable. Combined, they pack radiators at sub-wavelength spacings within and across layers, where mutual coupling governs the physics that current models omit. This paper develops a coupling-consistent model of a fluid transmit layer illuminating a stack of passive fluid beyond-diagonal layers. The multiport impedance matrix of any port constellation is shown to be the impedance kernel sampled at the three-dimensional separations, in one closed spherical-Hankel form whose in-plane restriction is intra-layer coupling and whose axial restriction replaces the scalar Rayleigh--Sommerfeld propagator. Only the transmitter is driven: the layer currents are induced, and the familiar cascade is the single-pass limit of one matrix inversion. In the wavenumber domain the light circle still separates radiation from reaction, now with a plane-wave propagator attached, every Fourier mode sees a transmission line loaded by the layers, and an efficiency identity shows that what the stack costs in efficiency is set by its total induced-current norm, not by its layer count. Because the load is never assumed layer-diagonal, interconnections may join atoms on different sheets, and vertical networks repeated at every site are spectrally local. Alternating optimization designs precoders, positions, and loads with closed-form gradients. Numerically, fluid ports on a $λ/8$ grid perform within a few per cent of continuously movable ones, while a design based on the conventional cascade model can do worse than open-circuiting the stack.

0.21