CS Paper Radar

Localized Thermal Management of Induction-Heated Microrobots for Hyperthermia Applications

Advika Balaji, Miguel F. Arevalo-Castiblanco, Aaron T. Becker

eess.SY ·submitted 2026-10-06 20:15 UTC · v1
unusual

Abstract

Induction-heated microrobots face a fundamental thermal management challenge: the alternating magnetic fields required for localized hyperthermia simultaneously generate parasitic ohmic heating within the actuation coils. Conventional cooling approaches can fail because conductive cooling structures placed near the coil can couple to the time-varying field, generating additional electromagnetic losses. This paper addresses this architectural limitation by evaluating two liquid-cooling frameworks designed to isolate the electromagnetic workspace: an indirect configuration utilizing an external copper water block, and a direct architecture routing coolant internally through a hollow helical coil. Evaluated over a 100~s window with multi-point thermocouple telemetry, the indirect water-block configuration failed due to secondary inductive coupling with the block itself, acting as an unintended susceptor that drove the block temperature to an extreme peak of 805$^{\circ}$C. In contrast, the direct internal cooling architecture successfully extracted ohmic losses at the source, sustaining a localized ablation tip temperature of 63.4$^{\circ}$C while strictly restricting surrounding fluid and boundary surfaces below defined thresholds of 33.9$^{\circ}$C and 37.6$^{\circ}$C, respectively. These results establish coil-level fluidic integration as a key design principle for thermally isolated microrobot actuation and provide a hardware foundation for future spatially controlled hyperthermia.

Comment
6 pages, 10 figures, Submitted to ICRA 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Autonomous thermodynamic cycles via robotic mobility and sensing

cs.CE cond-mat.softcs.ROeess.SY+1 ·2026-10-08 ·Sofia Kuperman, Ezra Ben-Abu, Yaron Veksler, Anna Zigelman, Sefi Givli +1 more
similarity 0.44
Abstract

Thermodynamic cycles are the foundation of energy conversion across natural and engineered systems, transforming heat into useful work. However, these cycles traditionally operate between fixed thermal reservoirs, restricting them to specific locations and temperature differences. Here, we introduce autonomous thermodynamic cycles enabled by robotic mobility and sensing, allowing robots to perform thermodynamic cycles by accessing spatially varying temperature fields. We experimentally realize this concept using multistable gas-filled capsules that circulate within the system across a thermal gradient. Our model reveals that rapid transitions in the capsules' energy states allow the system to operate as a mobile heat engine that harvests and stores energy. By linking the capsule-scale internal energy dynamics to the robot's large-scale navigation strategy, we optimize locomotion paths that balance motion cost and energy harvesting. These findings demonstrate that thermodynamic cycles can emerge when autonomous systems navigate their environments, offering an artificial analog of organisms that forage for energy across spatial resources.

0.28

SunLightBots: Turning sunlight into self-sustained, high-power motion in soft robots

cs.RO cond-mat.softphysics.app-ph ·2026-11-10 ·Yoo Jin Lee, Melanie Torres Crespo, Zhongxiao Deng, Andrew Tejada-Vega, Rebecca Kramer-Bottiglio +2 more
similarity 0.41
Abstract · 17 pages, 7 figures

Soft robots built from active materials can directly convert environmental stimuli into motion, offering a route to energy autonomy and embodied control. However, environmental energy is generally harvested at low power, whereas rapid, mechanically demanding actions require high mechanical output power. Reconciling this mismatch while sustaining self-regulated cyclic actuation is challenging, particularly at the subgram scale, where limited payload capacity constrains the integration of conventional power and control hardware. Here, we present SunLightBots, a class of subgram, sunlight-powered, untethered soft robots that achieve autonomous locomotion under continuous illumination near 1 Sun (100 mW/cm2). Their operation is enabled by a self-resetting snapping (SRS) mechanism that integrates liquid crystal elastomers (LCEs) with snap-through instability to accumulate solar energy supplied at low power, release it as rapid, high-power motion, and reset through photothermal-mechanical feedback. Through coordinated optimization of the LCE actuation temperature, photothermal conversion, actuation stress, and structural energy barrier, the system operates near 1 Sun and achieves a peak mass-specific mechanical power of 89 W/kg. At this irradiance, the optimized LCE generates an actuation stress of 0.1 MPa at approximately 60 deg C. SunLightBots demonstrate sustained swimming, crawling, and repeated impulsive jumping. Under 1.5 Suns, the swimmer advances more than three body lengths per cycle. This work provides a materials-mechanics route toward autonomous soft robots powered entirely by the environment.

0.27

Winding-Pack Quench Simulation of Stellarator Coils: Hydraulic Field-Network Coupling and Transverse Heat Conduction in OPENSC$^2$

cs.CE physics.comp-phphysics.plasm-ph ·2026-11-05 ·Laura A. M. D'Angelo, Felix Warmer
code/dataunusual similarity 0.40
Abstract · 31 pages, 24 figures, 2 tables. Submitted for publication in Superconductor Science and Technology

Quench propagation in cable-in-conduit conductors is thermo-hydraulically driven, yet existing 1D models treat a conductor as one straight adiabatic cable with prescribed pressure and mass-flow boundaries, so secondary quenches and flow redistribution between windings cannot be resolved. We extend the open-source code OPENSC$^2$ with transverse heat conduction between turns, a 3D field resolving the current-sharing temperature, induced losses, and a lumped hydraulic network coupled to the conductors by a mass-flow formulation. Validated against the 2006 W7-X coil tests, it predicts the quench site, cuts the outlet-temperature error from 55 K to 12 K, and reproduces the neighboring windings' heating as flow reversal through the coil inlet.

0.41

Modeling Liquid-Cooled Data Centers in EnergyPlus

eess.SY cs.CEcs.DCcs.LG ·2026-10-23 ·Yun-Dam Ko, Dipashreya A. Sur, Cade Napier, Carlos D. Díaz-Marín, Rishee K. Jain
code/data similarity 0.40
Abstract · 14 pages, 7 figures, 6 tables. Code: https://github.com/Urban-Informatics-Lab/energyplus-liquid-cooling

As AI workloads accelerate data center transition toward high-density racks with direct-to-chip (DTC) liquid cooling, existing simulation tools remain limited in evaluating whole-building and multi-year efficiency. To bridge this gap, we develop a native EnergyPlus object, ElectricEquipment:ITE:LiquidCooled, that models DTC liquid cooling for chilled-water and warm-water architectures as plant-loop components. It couples facility-water loops, rack-side secondary loops, coolant distribution units, and chip-junction temperatures within a single solver. Validation against an independent Modelica implementation across 21 operating conditions, including two full-year runs compared at one-minute resolution, yields loop-temperature RMSE at or below 0.021 K, well within the 0.1 K acceptance threshold. Our case study demonstrates that warm-water liquid cooling reduces annual PUE from 1.43 to 1.25, eliminates on-site water use, and cuts total facility energy by 37.9% relative to an air-cooled baseline. By embedding liquid-cooling logic into EnergyPlus, our work provides whole-building, long-term energy modeling for high-density AI infrastructure within an open-source framework.

0.31

Generative Design of Liquid-Cooling Channels for Thermal Management of 2.5D and 3D Integrated Advanced Packaging

eess.SY ·2026-08-24 ·Michael Acquah, Zheng Liu
similarity 0.40
Abstract · 29 pages, 5 figures

High-power multi-chip packages require increasingly effective cooling as intensive heat is generated within a limited package area. This work presents a physics-guided generative design framework for liquid-cooling channel topology optimization in a 2.7 kW multi-chip package containing two high-power graphics processing units (GPUs) and one central processing unit (CPU). A conditional diffusion model generates symmetric channel layouts using maximum GPU temperature, GPU temperature spread, and pressure drop as performance targets. Generated designs undergo connectivity and dead-end-branch screening and are evaluated using a calibrated reduced-order thermal-fluids model. Based on 5,000 generated layouts, the multi-objective analysis identified the optimal design for thermal properties, with estimated maximum GPU temperature of 70.30 degree Celsius, GPU temperature spread of 24.90 degree Celsius, and pressure drop of 89.72 kPa. Compared to a conventional reference topology, the optimal design reduced the maximum GPU temperature, temperature spread, and pressure drop by 33.6%, 52.5%, and 72.8%, respectively. High-fidelity three-dimensional conjugate heat-transfer simulation in OpenFOAM estimated a maximum GPU temperature of 66.70 degree Celsius and a pressure drop of 92.1 kPa, showing only differences of 8.6% in temperature rise and 2.6% in pressure drop. The results demonstrate that physics-guided generative design based on the reduced-order model can efficiently discover unconventional cooling channel architectures while reducing reliance on repeating computationally expensive simulation.

0.46

Selectively Actuated Fiberbots for High-precision Minimally Invasive Surgery

cs.RO ·2026-10-08 ·Jinshi Zhao, Libaihe Tian, Alex Ranne, Qindong Zheng, Yue Li +7 more
similarity 0.39
Abstract · 7 pages, 7 figures

Long, slender instruments are essential for minimally invasive surgery (MIS), but achieving precise distal manipulation becomes increasingly difficult when actuation extends along the entire instrument. Here, we present an electrothermally actuated fiber-based robot designed for MIS procedures, in which Joule heating is concentrated in the distal active segment. The fiber is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 $μ$m. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allow independent motion. A phantom demonstration combining the robotic fiber with a da Vinci instrument conceptually demonstrated its compatibility with existing endoscopic systems for clinical applications. Our robotic fiber enables precise distal motion and holds the potential to improve clinical outcomes by enhancing precision in MIS procedures.

0.33

Velocity Optimization via Thermal Imaging Enhances Autonomous Tumor Resection

cs.RO ·2026-10-20 ·Naveed D. Riaziat, Jiawei Ge, Ethan Kilmer, Michael W. Mikula, Paul Maria Scheikl +4 more
similarity 0.39
Abstract · submitted to IEEE Access

Objective: To demonstrate and evaluate THERMO, a thermal-velocity optimization algorithm for autonomous electrosurgery, in ex vivo porcine tissue using the UR10e-based ASTR system. Methods: Thermography for Electrosurgical Rate Modulation via Optimization (ThERMO), a closed-loop algorithm that uses real-time thermal imaging data to minimize thermal injury while ensuring accurate cut margins, was tested on ex vivo porcine tissue. Histological analysis was performed to detect thermal injury extent at a cellular level, and 3D photogrammetric measurement was used to verify margin accuracy. ThERMO's performance was compared against two previously used fixed velocity methods. Results: ThERMO outperformed both fixed velocity comparison methods without requiring data-driven training or iterative tuning, reducing thermal injury by up to 52%, improving cut accuracy by up to 59%, and maintaining task completion speed. Conclusions: Closed-loop thermal feedback via ThERMO improves autonomous robotic electrosurgery by simultaneously reducing thermal injury and improving margin accuracy, reinforcing its value over fixed velocity approaches for tumor resection applications. Significance: This work advances autonomous robotic tumor resection by demonstrating that real-time closed-loop thermal feedback control can substantially reduce collateral tissue damage and improve surgical margin accuracy.

0.23

AI Surge Accelerates the Transition to Liquid Cooling: Rethinking Energy and Water Use in Data Center Cooling

cs.CY ·2026-11-18 ·Yingbo Zhang, Eric Masanet, Shengwei Wang
similarity 0.39
Abstract

The power density of AI workloads is rapidly driving shifts to liquid cooling. This study rethinks and assesses the global impact on energy and water demand of this cooling transformation. Results suggest that liquid cooling can reduce cooling energy use by 25-56% relative to air cooling, offering substantial energy savings for GW-scale AI data centers. Best-practice PUE values could be as low as 1.07-1.08 for today's systems and 1.03-1.04 for emerging designs, and WUE values range from 0.38 to 2.63 L/kWh, depending on temperature conditions. We identify global free-cooling rack inlet temperature thresholds of 33 $^\circ$C for evaporative systems and 49 $^\circ$C for dry systems, demonstrating the practicality of 100% free cooling in many locations. The model finds that minimum PUEs do not necessarily coincide with minimum total energy use, because warmer coolant raises server power. Results quantify the large sustainability potential of liquid cooling and provide actionable targets for data center design and policies.

0.20