CS Paper Radar

Winding-Pack Quench Simulation of Stellarator Coils: Hydraulic Field-Network Coupling and Transverse Heat Conduction in OPENSC$^2$

Laura A. M. D'Angelo, Felix Warmer

cs.CE physics.comp-phphysics.plasm-ph ·submitted 2026-11-05 14:31 UTC · v1
code/dataunusual

Abstract

Quench propagation in cable-in-conduit conductors is thermo-hydraulically driven, yet existing 1D models treat a conductor as one straight adiabatic cable with prescribed pressure and mass-flow boundaries, so secondary quenches and flow redistribution between windings cannot be resolved. We extend the open-source code OPENSC$^2$ with transverse heat conduction between turns, a 3D field resolving the current-sharing temperature, induced losses, and a lumped hydraulic network coupled to the conductors by a mass-flow formulation. Validated against the 2006 W7-X coil tests, it predicts the quench site, cuts the outlet-temperature error from 55 K to 12 K, and reproduces the neighboring windings' heating as flow reversal through the coil inlet.

Comment
31 pages, 24 figures, 2 tables. Submitted for publication in Superconductor Science and Technology

Closest papers

Nearest neighbours by meaning across the whole index.

Rapid Heat Removal from Chip Cores: Near-Junction Active Cooling of Power Transistors via Electron Entropy Transport and Spatial Decoupling

eess.SY math-ph ·2026-11-09 ·Xiangying Li
unusual similarity 0.42
Abstract · 10pages

Chip performance is limited by a shared bottleneck: the core produces heat faster than it can be moved out. We study the hardest case, RF power GaN HEMTs, whose hotspots exceed 5 kW/cm^2, and propose a horizontal near-junction active cooling topology built on electron entropy transport. Classical on-chip thermoelectric cooling faces a contest: Peltier absorption grows linearly with current, Joule heating with its square. In a vertical pillar, its own conduction resistance locks about half the Joule heat back toward the cold end, capping net cooling. From the Onsager framework we show the origin of this asymmetry: Peltier absorption localizes at the interface where the Seebeck coefficient jumps, whereas Joule heating fills the volume. The topology exploits this: a thermoelectric thin film lies flat on a diamond substrate beside the device drain (the electron exit), so bulk Joule heat leaves vertically into the substrate. A lateral fin model gives a closed form for the recirculation factor gamma: the vertical pillar yields gamma = 1, while the horizontal film yields gamma_max = sqrt(2) L_z/L_x, about 0.03 for L_z = 10 um, L_x = 500 um. The decoupling scales the net cooling ceiling and the critical runaway current by roughly 1/gamma. At equal resistance, the same film lifts maximum cooling from 13 mW to 500 mW, and the critical current from 0.65 A to 24 A. A time-constant and linear stability analysis with temperature-sensitive parameters defines the working window and safety margins for microsecond pulse cooling. The architecture leaves the device structure untouched; the principle, absorb at an interface and extract bulk heat vertically, applies to any chip with a hot core and offers a reproducible design path for near-junction thermal management.

0.28

An end-to-end differentiable transient vapor-compression framework for automated machine sizing and unified optimal control

eess.SY cs.CEphysics.app-ph ·2026-08-20 ·Sam Yang
code/data similarity 0.41
Abstract · the paper is not novel enough; need further investigation

Accelerating the electrification of thermal energy requires vapor-compression heat pumps capable of dynamic, grid-responsive operation. However, equipment engineering remains fragmented across static rating-point selection, stiff multi-phase transient simulation, and gradient-based optimal control. Here, we present an end-to-end differentiable, finite-volume vapor-compression framework implemented natively in JAX that automates machine sizing directly from stated thermal duties and unifies dynamic simulation with predictive control under a single compiled residual $\dot{y}={f}(t,{y},{u})$. Thermodynamic evaluations bypass runtime root-finding via bilinear $(p,h)$ manifolds pre-flashed from Helmholtz equations of state, enabling analytical forward-mode automatic differentiation. Mass conservation across multi-phase coils is strictly preserved by incorporating both $(\partialρ/\partial p)_h$ and $(\partialρ/\partial h)_p$ partial derivatives into the dynamic pressure differential equation. The sizer directly inverts compressor displacement, electronic expansion valve area, and heat-exchanger tube counts via four-point cycle synthesis and $\varepsilon$-NTU matching using the identical polytropic compressor map. Crucially, the compiled physics kernel is shared symmetrically between $L$-stable TR-BDF2 stiff integration and implicit-Euler Model Predictive Control (MPC), eliminating plant-controller surrogate mismatch. Validated against open-access experimental benchmarks without parameter fitting, the framework predicts cooling capacity with $7.37\%$ MAPE across 16 mini-split operational runs and bounds on-period cooling error within $1.19\%$--$1.62\%$ on utility-scale Hardware-in-the-Loop traces. This work provides an open-source, differentiable foundation for automated machine synthesis, dynamic grid orchestration, and gradient-based hardware-control co-design.

0.36

CoilStellaration: A Dataset and Benchmark for Engineering-Aware Stellarator Coilset Generation

cs.LG physics.plasm-ph ·2026-11-09 ·Jan-Hendrik Ewers, Santiago A. Cadena, Nicolò Foppiani, Andrea Merlo
publishedbenchmarkdataset similarity 0.41
Abstract · 40th Conference on Neural Information Processing Systems (NeurIPS 2026). Track on Evaluations and Datasets

Stellarators are fusion devices that use externally generated, three-dimensional magnetic fields to confine hot plasma and offer a promising route to commercial fusion. Their electromagnetic coils pose a challenging design problem: they must reproduce the target magnetic field while satisfying engineering constraints and remaining practical and cost-effective to manufacture. Finding suitable geometries is a highly nonlinear inverse problem that generally has neither a closed-form nor a unique solution. This problem lies at the heart of stellarator design. We introduce CoilStellaration, a dataset and benchmark for learning the mapping between coil geometries from target plasma magnetic fields and engineering requirements. The dataset contains 177,000 optimized filamentary coilsets targeting plasma equilibria from ConStellaration, with sampled engineering requirements and achieved geometric and magnetic-field metrics. It spans multiple coil counts and field-period numbers, supporting studies of both specialized and shared models across configurations. The benchmark asks models to predict coils conditioned on a target equilibrium and requirements on coil-coil and coil-plasma spacing, curvature, and magnetic-field error. We show that magnetic-field accuracy remains the main challenge, with learned models rarely satisfying all requirements simultaneously. However, using learned predictions to initialize conventional coil optimization can accelerate early progress. We release baseline models and evaluation code to support reproducible research on both direct coil generation and learned optimization initializations. By lowering the barrier for machine learning and optimization researchers to engage with stellarator coil design, we aim to accelerate progress toward practical, cost-effective stellarator power plants.

0.41

Localized Thermal Management of Induction-Heated Microrobots for Hyperthermia Applications

eess.SY ·2026-10-06 ·Advika Balaji, Miguel F. Arevalo-Castiblanco, Aaron T. Becker
unusual similarity 0.40
Abstract · 6 pages, 10 figures, Submitted to ICRA 2026

Induction-heated microrobots face a fundamental thermal management challenge: the alternating magnetic fields required for localized hyperthermia simultaneously generate parasitic ohmic heating within the actuation coils. Conventional cooling approaches can fail because conductive cooling structures placed near the coil can couple to the time-varying field, generating additional electromagnetic losses. This paper addresses this architectural limitation by evaluating two liquid-cooling frameworks designed to isolate the electromagnetic workspace: an indirect configuration utilizing an external copper water block, and a direct architecture routing coolant internally through a hollow helical coil. Evaluated over a 100~s window with multi-point thermocouple telemetry, the indirect water-block configuration failed due to secondary inductive coupling with the block itself, acting as an unintended susceptor that drove the block temperature to an extreme peak of 805$^{\circ}$C. In contrast, the direct internal cooling architecture successfully extracted ohmic losses at the source, sustaining a localized ablation tip temperature of 63.4$^{\circ}$C while strictly restricting surrounding fluid and boundary surfaces below defined thresholds of 33.9$^{\circ}$C and 37.6$^{\circ}$C, respectively. These results establish coil-level fluidic integration as a key design principle for thermally isolated microrobot actuation and provide a hardware foundation for future spatially controlled hyperthermia.

0.29

Generative Design of Liquid-Cooling Channels for Thermal Management of 2.5D and 3D Integrated Advanced Packaging

eess.SY ·2026-08-24 ·Michael Acquah, Zheng Liu
similarity 0.39
Abstract · 29 pages, 5 figures

High-power multi-chip packages require increasingly effective cooling as intensive heat is generated within a limited package area. This work presents a physics-guided generative design framework for liquid-cooling channel topology optimization in a 2.7 kW multi-chip package containing two high-power graphics processing units (GPUs) and one central processing unit (CPU). A conditional diffusion model generates symmetric channel layouts using maximum GPU temperature, GPU temperature spread, and pressure drop as performance targets. Generated designs undergo connectivity and dead-end-branch screening and are evaluated using a calibrated reduced-order thermal-fluids model. Based on 5,000 generated layouts, the multi-objective analysis identified the optimal design for thermal properties, with estimated maximum GPU temperature of 70.30 degree Celsius, GPU temperature spread of 24.90 degree Celsius, and pressure drop of 89.72 kPa. Compared to a conventional reference topology, the optimal design reduced the maximum GPU temperature, temperature spread, and pressure drop by 33.6%, 52.5%, and 72.8%, respectively. High-fidelity three-dimensional conjugate heat-transfer simulation in OpenFOAM estimated a maximum GPU temperature of 66.70 degree Celsius and a pressure drop of 92.1 kPa, showing only differences of 8.6% in temperature rise and 2.6% in pressure drop. The results demonstrate that physics-guided generative design based on the reduced-order model can efficiently discover unconventional cooling channel architectures while reducing reliance on repeating computationally expensive simulation.

0.46

Modeling Liquid-Cooled Data Centers in EnergyPlus

eess.SY cs.CEcs.DCcs.LG ·2026-10-23 ·Yun-Dam Ko, Dipashreya A. Sur, Cade Napier, Carlos D. Díaz-Marín, Rishee K. Jain
code/data similarity 0.39
Abstract · 14 pages, 7 figures, 6 tables. Code: https://github.com/Urban-Informatics-Lab/energyplus-liquid-cooling

As AI workloads accelerate data center transition toward high-density racks with direct-to-chip (DTC) liquid cooling, existing simulation tools remain limited in evaluating whole-building and multi-year efficiency. To bridge this gap, we develop a native EnergyPlus object, ElectricEquipment:ITE:LiquidCooled, that models DTC liquid cooling for chilled-water and warm-water architectures as plant-loop components. It couples facility-water loops, rack-side secondary loops, coolant distribution units, and chip-junction temperatures within a single solver. Validation against an independent Modelica implementation across 21 operating conditions, including two full-year runs compared at one-minute resolution, yields loop-temperature RMSE at or below 0.021 K, well within the 0.1 K acceptance threshold. Our case study demonstrates that warm-water liquid cooling reduces annual PUE from 1.43 to 1.25, eliminates on-site water use, and cuts total facility energy by 37.9% relative to an air-cooled baseline. By embedding liquid-cooling logic into EnergyPlus, our work provides whole-building, long-term energy modeling for high-density AI infrastructure within an open-source framework.

0.31

COOL: A Cooling-Aware Point Transformer Framework for Thermal Prediction in Advanced 3D/3.5D IC Packaging

cs.CE ·2026-08-16 ·Yao Lu, Zhicheng Guo, Qijun Zhang, Shang Liu, Wenji Fang +2 more
publishedbenchmark similarity 0.39
Abstract · 7 pages, accepted at DAC 2026

Advanced 3D and 3.5D IC packaging significantly improves integration density but elevates thermal management challenges due to cross-layer heat coupling and complex cooling structures. Traditional solvers deliver high fidelity but are too slow for iterative design flows, while existing learning-based methods either fail to capture inter-die thermal coupling or treat cooling structures as static components, limiting their applicability in real packaging co-design scenarios. In this work, we introduce COOL, a cooling-aware point transformer framework that represents heterogeneous assemblies (dies, interposers, TIMs, heat spreaders) as annotated 3D point clouds embedding geometric, material and power attributes. COOL explicitly encodes geometric boundaries and cooling structures, and introduces a physics-informed boundary condition (PI-BC) loss to enforce thermal consistency at material interfaces and cooling boundaries. Extensive experiments demonstrate that COOL achieves a remarkable 2.4\% NMAE on our constructed benchmark of multi-package thermal designs, substantially outperforming existing learning-based approaches while providing over 15.7x speedup compared to commercial FEM solvers.

0.28

AI for Science with GPT-6 Astra: Thermal Design and Electrothermal Analysis of 2D CFET

cs.AI cond-mat.mtrl-scics.AR ·2026-09-15 ·Min-Hui Kim, Khushi Sharma, Sarah Zhang, Ye Wang
similarity 0.38
Abstract

Thermal optimization of 2D CFET inverters requires testing structural proposals against their electrical costs. We examine these research tasks using an AI agent workflow within a supplied electrothermal model. At 12 nm, Astra selects a redistributed source-interconnect geometry, while a coordinating agent proposes a substrate-directed heat-removal path. The combined design reduces peak temperature rise by 1.67 K at fixed metal volume and 20 μW. A subsequent metal-resistance sensitivity gives about 0.6-K inverter cooling alongside a 2% nFET on-current loss. Effective contact-length scaling further shows that lower temperature can accompany higher thermal resistance when current falls. Reproduction identifies agreeing implementations and retains a 104.95-K failure for diagnosis. These results show that an AI scientist workflow can propose thermal structures, test them under common constraints, and quantify their electrical cost.

0.35